Prediction of maximal oxygen uptake in sedentary males from a perceptually regulated, sub-maximal graded exercise test
Prediction of maximal oxygen uptake in sedentary males from a perceptually regulated, sub-maximal graded exercise test
The purpose of this study was to assess the validity of predicting the maximal oxygen uptake (VO2(max)) of sedentary men from sub-maximal VO2 values obtained during a perceptually regulated exercise test. Thirteen healthy, sedentary males aged 29-52 years completed five graded exercise tests on a cycle ergometer. The first and fifth test involved a graded exercise test to determine VO2(max). The two maximal graded exercise tests were separated by three sub-maximal graded exercise tests, perceptually regulated at 3-min RPE intensities of 9, 11, 13, 15, and 17 on the Borg ratings of perceived exertion (RPE) scale, in that order. After confirmation that individual linear regression models provided the most appropriate fit to the data, the regression lines for the perceptual ranges 9-17, 9-15, and 11-17 were extrapolated to RPE 20 to predict VO2(max). There were no significant differences between VO2(max) values from the graded exercise tests (mean 43.9 ml x kg(-1) x min(-1), s = 6.3) and predicted VO2(max) values for the perceptual ranges 9-17 (40.7 ml x kg(-1) x min(-1), s = 2.2) and RPE 11-17 (42.5 ml x kg(-1) x min(-1), s = 2.3) across the three trials. The predicted VO2(max) from the perceptual range 9-15 was significantly lower (P < 0.05) (37.7 ml x kg(-1) x min(-1), s = 2.3). The intra-class correlation coefficients between actual and predicted VO2(max) for RPE 9-17 and RPE 11-17 across trials ranged from 0.80 to 0.87. Limits of agreement analysis on actual and predicted VO2 values (bias +/- 1.96 x S(diff)) were 3.4 ml x kg(-1) x min(-1) (+/- 10.7), 2.4 ml x kg(-1) x min(-1) (+/- 9.9), and 3.7 ml x kg(-1) x min(-1) (+/- 12.8) (trials 1, 2, and 3, respectively) of RPE range 9-17. Results suggest that a sub-maximal, perceptually guided graded exercise test provides acceptable estimates of VO2(max) in young to middle-aged sedentary males.
131-139
Eston, Roger
c2b0f27b-b9fc-4f6c-8429-4cfb7bb2a74a
Lambrick, Danielle
1deafa4b-acf3-4eff-83c9-f8274e47e993
Sheppard, Kate
167f4260-d0fa-4450-a52d-02fcd9e9d87b
Parfitt, Gaynor
e845ce05-957e-466b-a16b-6127c57d0c9a
15 January 2008
Eston, Roger
c2b0f27b-b9fc-4f6c-8429-4cfb7bb2a74a
Lambrick, Danielle
1deafa4b-acf3-4eff-83c9-f8274e47e993
Sheppard, Kate
167f4260-d0fa-4450-a52d-02fcd9e9d87b
Parfitt, Gaynor
e845ce05-957e-466b-a16b-6127c57d0c9a
Eston, Roger, Lambrick, Danielle, Sheppard, Kate and Parfitt, Gaynor
(2008)
Prediction of maximal oxygen uptake in sedentary males from a perceptually regulated, sub-maximal graded exercise test.
Journal of Sports Sciences, 26 (2), .
(PMID:17852665)
Abstract
The purpose of this study was to assess the validity of predicting the maximal oxygen uptake (VO2(max)) of sedentary men from sub-maximal VO2 values obtained during a perceptually regulated exercise test. Thirteen healthy, sedentary males aged 29-52 years completed five graded exercise tests on a cycle ergometer. The first and fifth test involved a graded exercise test to determine VO2(max). The two maximal graded exercise tests were separated by three sub-maximal graded exercise tests, perceptually regulated at 3-min RPE intensities of 9, 11, 13, 15, and 17 on the Borg ratings of perceived exertion (RPE) scale, in that order. After confirmation that individual linear regression models provided the most appropriate fit to the data, the regression lines for the perceptual ranges 9-17, 9-15, and 11-17 were extrapolated to RPE 20 to predict VO2(max). There were no significant differences between VO2(max) values from the graded exercise tests (mean 43.9 ml x kg(-1) x min(-1), s = 6.3) and predicted VO2(max) values for the perceptual ranges 9-17 (40.7 ml x kg(-1) x min(-1), s = 2.2) and RPE 11-17 (42.5 ml x kg(-1) x min(-1), s = 2.3) across the three trials. The predicted VO2(max) from the perceptual range 9-15 was significantly lower (P < 0.05) (37.7 ml x kg(-1) x min(-1), s = 2.3). The intra-class correlation coefficients between actual and predicted VO2(max) for RPE 9-17 and RPE 11-17 across trials ranged from 0.80 to 0.87. Limits of agreement analysis on actual and predicted VO2 values (bias +/- 1.96 x S(diff)) were 3.4 ml x kg(-1) x min(-1) (+/- 10.7), 2.4 ml x kg(-1) x min(-1) (+/- 9.9), and 3.7 ml x kg(-1) x min(-1) (+/- 12.8) (trials 1, 2, and 3, respectively) of RPE range 9-17. Results suggest that a sub-maximal, perceptually guided graded exercise test provides acceptable estimates of VO2(max) in young to middle-aged sedentary males.
This record has no associated files available for download.
More information
Published date: 15 January 2008
Organisations:
Faculty of Health Sciences
Identifiers
Local EPrints ID: 382325
URI: http://eprints.soton.ac.uk/id/eprint/382325
ISSN: 0264-0414
PURE UUID: 52c27049-a837-46e5-98b4-18c72fb19c0b
Catalogue record
Date deposited: 01 Oct 2015 16:07
Last modified: 23 Jul 2022 02:10
Export record
Contributors
Author:
Roger Eston
Author:
Kate Sheppard
Author:
Gaynor Parfitt
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics