Broadband ultrasonic attenuation: are current measurement techniques inherently inaccurate?

Broadband ultrasonic attenuation: are current measurement techniques inherently inaccurate?
Broadband ultrasonic attenuation: are current measurement techniques inherently inaccurate?
Measurements of broadband ultrasonic attenuation (BUA) are currently made using large aperture, piezoelectric transducers. The use of such a receiver is known to lead to the possibility of an overestimate of ultrasonic attenuation due to phase cancellation and it is shown theoretically that this same effect can also lead to an overestimate of BUA. Using a new scanning approach, BUA was measured using two methods, one sensitive to the phase of the acoustic wave, the other not. The phase sensitive BUA measurements were found to be of significantly higher value (p < 0.0001) than the phase insensitive measurements with a mean difference of 31.2 dB MHz-1. These findings are compatible with the hypothesis that BUA measurement systems with large aperture, piezo-electric receivers are inherently inaccurate.
0007-1285
1212-1214
Petley, G.W.
4f2da40b-3c7b-4adc-b75c-e24e62bb1cf0
Robins, P.A.
bf05f166-be56-4d81-9fb0-43499f1c36dd
Aindow, J.D.
c07d68ed-258f-4f96-ab15-d743bd5b967c
Petley, G.W.
4f2da40b-3c7b-4adc-b75c-e24e62bb1cf0
Robins, P.A.
bf05f166-be56-4d81-9fb0-43499f1c36dd
Aindow, J.D.
c07d68ed-258f-4f96-ab15-d743bd5b967c

Petley, G.W., Robins, P.A. and Aindow, J.D. (1995) Broadband ultrasonic attenuation: are current measurement techniques inherently inaccurate? British Journal of Radiology, 68 (815), 1212-1214. (doi:10.1259/0007-1285-68-815-1212). (PMID:8542228)

Record type: Article

Abstract

Measurements of broadband ultrasonic attenuation (BUA) are currently made using large aperture, piezoelectric transducers. The use of such a receiver is known to lead to the possibility of an overestimate of ultrasonic attenuation due to phase cancellation and it is shown theoretically that this same effect can also lead to an overestimate of BUA. Using a new scanning approach, BUA was measured using two methods, one sensitive to the phase of the acoustic wave, the other not. The phase sensitive BUA measurements were found to be of significantly higher value (p < 0.0001) than the phase insensitive measurements with a mean difference of 31.2 dB MHz-1. These findings are compatible with the hypothesis that BUA measurement systems with large aperture, piezo-electric receivers are inherently inaccurate.

This record has no associated files available for download.

More information

Published date: November 1995
Organisations: Faculty of Medicine

Identifiers

Local EPrints ID: 383396
URI: http://eprints.soton.ac.uk/id/eprint/383396
ISSN: 0007-1285
PURE UUID: 294e0603-9afd-4e37-b08a-2a37a9704160
ORCID for G.W. Petley: ORCID iD orcid.org/0000-0002-3295-0444

Catalogue record

Date deposited: 20 Jan 2016 13:04
Last modified: 15 Mar 2024 02:53

Export record

Altmetrics

Contributors

Author: G.W. Petley ORCID iD
Author: P.A. Robins
Author: J.D. Aindow

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×