We present a new light source for parallel OCT based on multiple waveguides written in Ti:sapphire. Each channel can generate a spectrum of 174 nm bandwidth centered at 772 nm, with an optical power on sample of 30 µW. A system depth resolution of 1.9 µm is obtained, which correspond to 1.5 µm in tissue.
Bourquin, S.
19233c6a-4a22-4fca-a5d1-b5ebe122f0dc
Laversenne, L.
08bf9feb-0fb3-49de-b3bd-3973083145da
Rivier, S.
557fb9f4-bb99-4d19-99f7-811cf105b50a
Lasser, T.
03241a78-cf58-4271-8c96-3051bc3c0e77
Salathé, R.P.
ea67db6b-9d3a-4221-bb07-fc20064d2758
Pollnau, M.
1094856b-791a-4050-98d9-c07777d5f0f5
Grivas, Christos
7f564818-0ac0-4127-82a7-22e87ac35f1a
Shepherd, D.P.
9fdd51c4-39d6-41b3-9021-4c033c2f4ead
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Bourquin, S.
19233c6a-4a22-4fca-a5d1-b5ebe122f0dc
Laversenne, L.
08bf9feb-0fb3-49de-b3bd-3973083145da
Rivier, S.
557fb9f4-bb99-4d19-99f7-811cf105b50a
Lasser, T.
03241a78-cf58-4271-8c96-3051bc3c0e77
Salathé, R.P.
ea67db6b-9d3a-4221-bb07-fc20064d2758
Pollnau, M.
1094856b-791a-4050-98d9-c07777d5f0f5
Grivas, Christos
7f564818-0ac0-4127-82a7-22e87ac35f1a
Shepherd, D.P.
9fdd51c4-39d6-41b3-9021-4c033c2f4ead
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020

Bourquin, S., Laversenne, L., Rivier, S., Lasser, T., Salathé, R.P., Pollnau, M., Grivas, Christos, Shepherd, D.P. and Eason, R.W. (2005) Parallel broadband fluorescent light source for optical coherence tomography. Photonics West 2005. Bios Symposium, San Jose, USA. 22 - 27 Jan 2005. 3 pp .

Record type: Conference or Workshop Item (Paper)

Abstract

We present a new light source for parallel OCT based on multiple waveguides written in Ti:sapphire. Each channel can generate a spectrum of 174 nm bandwidth centered at 772 nm, with an optical power on sample of 30 µW. A system depth resolution of 1.9 µm is obtained, which correspond to 1.5 µm in tissue.

Text
2967.pdf - Accepted Manuscript
Download (604kB)

More information

Published date: 2005
Venue - Dates: Photonics West 2005. Bios Symposium, San Jose, USA, 2005-01-22 - 2005-01-27

Identifiers

Local EPrints ID: 38349
URI: http://eprints.soton.ac.uk/id/eprint/38349
PURE UUID: e73040f7-fcc9-476e-9e61-c80ce019ecb2
ORCID for D.P. Shepherd: ORCID iD orcid.org/0000-0002-4561-8184
ORCID for R.W. Eason: ORCID iD orcid.org/0000-0001-9704-2204

Catalogue record

Date deposited: 08 Jun 2006
Last modified: 16 Mar 2024 02:39

Export record

Contributors

Author: S. Bourquin
Author: L. Laversenne
Author: S. Rivier
Author: T. Lasser
Author: R.P. Salathé
Author: M. Pollnau
Author: Christos Grivas
Author: D.P. Shepherd ORCID iD
Author: R.W. Eason ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×