The performance of pressure cells for sprayed concrete tunnel linings

The performance of pressure cells for sprayed concrete tunnel linings
The performance of pressure cells for sprayed concrete tunnel linings
The paper examines the factors that affect the performance of tangential cells embedded in shotcrete tunnel linings. New data, derived from field monitoring, numerical modelling, and calibration tests carried out to simulate the embedment and crimping processes, are presented. These suggest that although well-designed embedded total pressure cells will have cell action factors close to unity, they cannot be assumed to provide reasonable estimates of the stresses within sprayed concrete linings, unless the influences of installation effects, temperature changes, shrinkage and subsequent crimping can be taken into account.
Cet exposé examine les facteurs qui affectent la performance des cellules tangentielles enfouies dans les doublures de tunnel en béton projeté. Nous présentons de nouvelles données, dérivées d'un suivi sur le terrain, d'une modélisation numérique et d'essais de calibrage effectués pour simuler les procédés d'enfouissement et d'amorçage. Ces données suggèrent qu'alors que les cellules, bien conçues et enfouies sous pression totale, ont des facteurs d'action proches de l'unité, on ne peut présumer qu'elles donnent des évaluations raisonnables des contraintes à l'intérieur les doublures en béton projeté, à moins de prendre en compte les influences des effets de l'installation, des changements de température, du retrait et de l'amorçage subséquent.
field instrumentation, tunnels
0016-8505
107-116
Clayton, C.R.I.
8397d691-b35b-4d3f-a6d8-40678f233869
Van der Berg, J.P.
40051846-d050-4a78-a348-9a093ae93720
Heymann, G.
4f086d55-d1c1-48df-a1a3-b552571cb0d3
Bica, A.V.D
0c884221-c53b-46fd-8300-3e5d006ebde5
Hope, V.S.
9dd533f5-648a-442f-ad85-77fc7d73d217
Clayton, C.R.I.
8397d691-b35b-4d3f-a6d8-40678f233869
Van der Berg, J.P.
40051846-d050-4a78-a348-9a093ae93720
Heymann, G.
4f086d55-d1c1-48df-a1a3-b552571cb0d3
Bica, A.V.D
0c884221-c53b-46fd-8300-3e5d006ebde5
Hope, V.S.
9dd533f5-648a-442f-ad85-77fc7d73d217

Clayton, C.R.I., Van der Berg, J.P., Heymann, G., Bica, A.V.D and Hope, V.S. (2002) The performance of pressure cells for sprayed concrete tunnel linings. Géotechnique, 52 (2), 107-116. (doi:10.1680/geot.52.2.107.40928).

Record type: Article

Abstract

The paper examines the factors that affect the performance of tangential cells embedded in shotcrete tunnel linings. New data, derived from field monitoring, numerical modelling, and calibration tests carried out to simulate the embedment and crimping processes, are presented. These suggest that although well-designed embedded total pressure cells will have cell action factors close to unity, they cannot be assumed to provide reasonable estimates of the stresses within sprayed concrete linings, unless the influences of installation effects, temperature changes, shrinkage and subsequent crimping can be taken into account.
Cet exposé examine les facteurs qui affectent la performance des cellules tangentielles enfouies dans les doublures de tunnel en béton projeté. Nous présentons de nouvelles données, dérivées d'un suivi sur le terrain, d'une modélisation numérique et d'essais de calibrage effectués pour simuler les procédés d'enfouissement et d'amorçage. Ces données suggèrent qu'alors que les cellules, bien conçues et enfouies sous pression totale, ont des facteurs d'action proches de l'unité, on ne peut présumer qu'elles donnent des évaluations raisonnables des contraintes à l'intérieur les doublures en béton projeté, à moins de prendre en compte les influences des effets de l'installation, des changements de température, du retrait et de l'amorçage subséquent.

This record has no associated files available for download.

More information

Published date: 2002
Keywords: field instrumentation, tunnels
Organisations: Civil Engineering & the Environment

Identifiers

Local EPrints ID: 39409
URI: http://eprints.soton.ac.uk/id/eprint/39409
ISSN: 0016-8505
PURE UUID: ad7393d6-0e22-4f69-acdd-c37dd8a8887b
ORCID for C.R.I. Clayton: ORCID iD orcid.org/0000-0003-0071-8437

Catalogue record

Date deposited: 28 Jun 2006
Last modified: 16 Mar 2024 03:12

Export record

Altmetrics

Contributors

Author: C.R.I. Clayton ORCID iD
Author: J.P. Van der Berg
Author: G. Heymann
Author: A.V.D Bica
Author: V.S. Hope

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×