The University of Southampton
University of Southampton Institutional Repository

A comparison of standardized methods for predicting the hazards of whole-body vibration and repeated shocks

A comparison of standardized methods for predicting the hazards of whole-body vibration and repeated shocks
A comparison of standardized methods for predicting the hazards of whole-body vibration and repeated shocks

Methods of measuring, evaluating and assessing whole-body vibration and repeated shock are offered in ISO 2631 (1974, 1985), BS 6841 (1987), and ISO 2631 (1997). This paper presents a comparison of guidance on the health effects of vibration and repeated shock given in these standards. International Standard 2631 (1974, 1985) offered a set of exposure limits. British Standard 6841 (1987) defines a measurement and evaluation procedure (based on frequency weightings and the vibration dose value, VDV), gives an action level that can be used to assess vibration severity, and mentions some appropriate actions (consideration of the fitness of exposed persons, design of safety precautions, regular health checks). International Standard 2631 (1997) is unclear in several important areas: which body postures and axes are to be assessed; whether evaluations of multi-axis vibration should be based on the "worst axis" or a combination of the frequency-weighted acceleration in all axes; why a new frequency weighting, Wk, is proposed for vertical vibration when it is almost within the error tolerance of an existing weighting, Wb; why a 1·4 multiplying factor is used to evaluate vibration with respect to health but not with respect to comfort; how to choose between different time-dependencies (overall r.m.s., VDV, running r.m.s., and no time-dependency); allowing use of either the maximum value of a running r.m.s. (i.e., MTVV) or the VDV; allowing different averaging periods when calculating the MTVV; using the crest factor to choose between r.m.s. and either the VDV or MTVV methods; defining two inconsistent criteria for deciding whether to use either the VDV or MTVV methods; giving no guidance on how MTVV values should be assessed; including two very different "health guidance caution zones" (for interpreting r.m.s. and VDV measures); providing ambiguous wording for the health guidance caution zones. Very different conclusions can be reached according to what is measured, how the vibration is evaluated and how it is assessed according to ISO 2631 (1997). However, even though it employs a slightly different frequency weighting for vertical vibration, and a 1·4 multiplying factor for horizontal vibration, ISO 2631 (1997) can be interpreted so as to provide evaluations similar to those made according to BS 6841 (1987). It is concluded that the recently revised International Standard for measuring, evaluating and assessing human exposures to vibration and shock will cause unnecessary confusion.

0022-460X
883-914
Griffin, M. J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Griffin, M. J.
24112494-9774-40cb-91b7-5b4afe3c41b8

Griffin, M. J. (1998) A comparison of standardized methods for predicting the hazards of whole-body vibration and repeated shocks. Journal of Sound and Vibration, 215 (4), 883-914. (doi:10.1006/jsvi.1998.1600).

Record type: Article

Abstract

Methods of measuring, evaluating and assessing whole-body vibration and repeated shock are offered in ISO 2631 (1974, 1985), BS 6841 (1987), and ISO 2631 (1997). This paper presents a comparison of guidance on the health effects of vibration and repeated shock given in these standards. International Standard 2631 (1974, 1985) offered a set of exposure limits. British Standard 6841 (1987) defines a measurement and evaluation procedure (based on frequency weightings and the vibration dose value, VDV), gives an action level that can be used to assess vibration severity, and mentions some appropriate actions (consideration of the fitness of exposed persons, design of safety precautions, regular health checks). International Standard 2631 (1997) is unclear in several important areas: which body postures and axes are to be assessed; whether evaluations of multi-axis vibration should be based on the "worst axis" or a combination of the frequency-weighted acceleration in all axes; why a new frequency weighting, Wk, is proposed for vertical vibration when it is almost within the error tolerance of an existing weighting, Wb; why a 1·4 multiplying factor is used to evaluate vibration with respect to health but not with respect to comfort; how to choose between different time-dependencies (overall r.m.s., VDV, running r.m.s., and no time-dependency); allowing use of either the maximum value of a running r.m.s. (i.e., MTVV) or the VDV; allowing different averaging periods when calculating the MTVV; using the crest factor to choose between r.m.s. and either the VDV or MTVV methods; defining two inconsistent criteria for deciding whether to use either the VDV or MTVV methods; giving no guidance on how MTVV values should be assessed; including two very different "health guidance caution zones" (for interpreting r.m.s. and VDV measures); providing ambiguous wording for the health guidance caution zones. Very different conclusions can be reached according to what is measured, how the vibration is evaluated and how it is assessed according to ISO 2631 (1997). However, even though it employs a slightly different frequency weighting for vertical vibration, and a 1·4 multiplying factor for horizontal vibration, ISO 2631 (1997) can be interpreted so as to provide evaluations similar to those made according to BS 6841 (1987). It is concluded that the recently revised International Standard for measuring, evaluating and assessing human exposures to vibration and shock will cause unnecessary confusion.

This record has no associated files available for download.

More information

Published date: 27 August 1998
Organisations: University of Southampton, Human Factors Research Unit

Identifiers

Local EPrints ID: 407916
URI: http://eprints.soton.ac.uk/id/eprint/407916
ISSN: 0022-460X
PURE UUID: 0e7fcd9b-0b07-4904-8bbc-f55cb52f2b30
ORCID for M. J. Griffin: ORCID iD orcid.org/0000-0003-0743-9502

Catalogue record

Date deposited: 28 Apr 2017 01:11
Last modified: 15 Mar 2024 12:23

Export record

Altmetrics

Contributors

Author: M. J. Griffin ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×