The University of Southampton
University of Southampton Institutional Repository

Direct determination of iron in acidified (pH 1.7) seawater samples by flow injection analysis with catalytic spectrophotometric detection: Application and intercomparison

Direct determination of iron in acidified (pH 1.7) seawater samples by flow injection analysis with catalytic spectrophotometric detection: Application and intercomparison
Direct determination of iron in acidified (pH 1.7) seawater samples by flow injection analysis with catalytic spectrophotometric detection: Application and intercomparison

A sensitive flow injection method for determining iron in seawater developed by Measures et al. (1995) has been substantially modified to allow the direct preconcentration of dissolved iron in acidified seawater samples (pH 1.7) onto a nitrilotriacetic acid (NTA) chelating resin. This removes the need to adjust the pH and buffer samples before the preconcentration step, and the low pH eliminates potential interference from the presence of strong iron-binding organic ligands. As part of an international intercalibration exercise for the Sampling and Analysis of Fe (SAFe), we investigated at sea the precision and accuracy of this flow injection method with its preconcentration step plus catalytic spectrophotometric detection with N,N-dimethyl-p-phenylenediamine dihydrochloride (FI-NTA-DPD). Acidified seawater samples analyzed using FI-NTA-DPD were shown to be in excellent agreement with other ship- and lab-based methods. The acidification of seawater samples to pH 1.7 is an important protocol if total dissolved iron in seawater is to be determined within hours of collection. A ship- and lab-based analytical intercomparison of two flow injection methods (FI-NTA-DPD and FI-NTA-ICP-SFMS) for the determination of total dissolved iron in seawater was carried out on SAFe samples collected from surface waters and at 1000 m depth from the North Pacific Ocean. For the two methods, total dissolved iron concentrations in surface samples were 0.101 ± 0.009 and 0.098 ± 0.009 nM, respectively, and in samples from 1000 m, 0.93 ± 0.04 and 0.92 ± 0.08 nM. No statistical difference between the FI-NTA-DPD and FI-NTA-ICP-SFMS methods was observed (P = 0.05).

1541-5856
164-171
Lohan, Maeve C.
6ca10597-2d0f-40e8-8e4f-7619dfac5088
Aguilar-Islas, Ana M.
95163f7a-93d5-4d52-8da0-c793d05bc8d7
Bruland, Kenneth W.
f3e947c6-f9b7-435c-ac84-b3476306a368
Lohan, Maeve C.
6ca10597-2d0f-40e8-8e4f-7619dfac5088
Aguilar-Islas, Ana M.
95163f7a-93d5-4d52-8da0-c793d05bc8d7
Bruland, Kenneth W.
f3e947c6-f9b7-435c-ac84-b3476306a368

Lohan, Maeve C., Aguilar-Islas, Ana M. and Bruland, Kenneth W. (2006) Direct determination of iron in acidified (pH 1.7) seawater samples by flow injection analysis with catalytic spectrophotometric detection: Application and intercomparison. Limnology and Oceanography: Methods, 4 (JUN.), 164-171.

Record type: Article

Abstract

A sensitive flow injection method for determining iron in seawater developed by Measures et al. (1995) has been substantially modified to allow the direct preconcentration of dissolved iron in acidified seawater samples (pH 1.7) onto a nitrilotriacetic acid (NTA) chelating resin. This removes the need to adjust the pH and buffer samples before the preconcentration step, and the low pH eliminates potential interference from the presence of strong iron-binding organic ligands. As part of an international intercalibration exercise for the Sampling and Analysis of Fe (SAFe), we investigated at sea the precision and accuracy of this flow injection method with its preconcentration step plus catalytic spectrophotometric detection with N,N-dimethyl-p-phenylenediamine dihydrochloride (FI-NTA-DPD). Acidified seawater samples analyzed using FI-NTA-DPD were shown to be in excellent agreement with other ship- and lab-based methods. The acidification of seawater samples to pH 1.7 is an important protocol if total dissolved iron in seawater is to be determined within hours of collection. A ship- and lab-based analytical intercomparison of two flow injection methods (FI-NTA-DPD and FI-NTA-ICP-SFMS) for the determination of total dissolved iron in seawater was carried out on SAFe samples collected from surface waters and at 1000 m depth from the North Pacific Ocean. For the two methods, total dissolved iron concentrations in surface samples were 0.101 ± 0.009 and 0.098 ± 0.009 nM, respectively, and in samples from 1000 m, 0.93 ± 0.04 and 0.92 ± 0.08 nM. No statistical difference between the FI-NTA-DPD and FI-NTA-ICP-SFMS methods was observed (P = 0.05).

This record has no associated files available for download.

More information

Published date: 2006

Identifiers

Local EPrints ID: 414020
URI: http://eprints.soton.ac.uk/id/eprint/414020
ISSN: 1541-5856
PURE UUID: f28f5563-bc74-4a9e-bf03-ce02e7239094
ORCID for Maeve C. Lohan: ORCID iD orcid.org/0000-0002-5340-3108

Catalogue record

Date deposited: 12 Sep 2017 16:31
Last modified: 28 Feb 2024 02:51

Export record

Contributors

Author: Maeve C. Lohan ORCID iD
Author: Ana M. Aguilar-Islas
Author: Kenneth W. Bruland

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×