Vertical bearing capacity of a shallow foundation with short skirts in normally consolidated clay has been investigated in the UWA drum centrifuge for embedment depths up to two footing diameters. Tests were carried out in a special fabricated strong box set into the channel of the drum. A half-model test was conducted adjacent to the strongbox Perspex window, facilitating optical measurement of soil deformation during foundation loading. A full-model test was conducted in the interior of the strongbox to ascertain the true bearing capacity as the half-model results are anticipated to be distorted by friction developed along the Perspex window. This paper describes the experimental techniques adopted and the results in terms of bearing capacity factor and the accompanying soil failure mechanisms.

645-650
Gourvenec, S.
6ff91ad8-1a91-42fe-a3f4-1b5d6f5ce0b8
O'Loughlin, C. D.
b0fc277d-6301-45fd-a2a5-438655f822b0
Gourvenec, S.
6ff91ad8-1a91-42fe-a3f4-1b5d6f5ce0b8
O'Loughlin, C. D.
b0fc277d-6301-45fd-a2a5-438655f822b0

Gourvenec, S. and O'Loughlin, C. D. (2006) Drum centrifuge tests of shallow skirted foundations on soft clay. In Physical Modelling in Geotechnics, 6th ICPMG'06 - Proceedings of the 6th International Conference on Physical Modelling in Geotechnics. vol. 1-2, pp. 645-650 .

Record type: Conference or Workshop Item (Paper)

Abstract

Vertical bearing capacity of a shallow foundation with short skirts in normally consolidated clay has been investigated in the UWA drum centrifuge for embedment depths up to two footing diameters. Tests were carried out in a special fabricated strong box set into the channel of the drum. A half-model test was conducted adjacent to the strongbox Perspex window, facilitating optical measurement of soil deformation during foundation loading. A full-model test was conducted in the interior of the strongbox to ascertain the true bearing capacity as the half-model results are anticipated to be distorted by friction developed along the Perspex window. This paper describes the experimental techniques adopted and the results in terms of bearing capacity factor and the accompanying soil failure mechanisms.

This record has no associated files available for download.

More information

Published date: 2006
Venue - Dates: 6th International Conference on Physical Modelling in Geotechnics, ICPMG'06, , Hong Kong, Hong Kong, 2006-08-03 - 2006-08-05

Identifiers

Local EPrints ID: 414644
URI: http://eprints.soton.ac.uk/id/eprint/414644
PURE UUID: efd43097-f0db-4f9c-abdb-01a80079e2eb
ORCID for S. Gourvenec: ORCID iD orcid.org/0000-0002-2628-7914

Catalogue record

Date deposited: 05 Oct 2017 16:30
Last modified: 09 Jan 2022 03:59

Export record

Contributors

Author: S. Gourvenec ORCID iD
Author: C. D. O'Loughlin

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×