Ti:sapphire rib waveguides as single-transverse-mode broadband fluorescence sources for optical coherence tomography applications
Ti:sapphire rib waveguides as single-transverse-mode broadband fluorescence sources for optical coherence tomography applications
Rib waveguides based on pulsed-laser-deposited Ti:sapphire thin films have been fabricated by Ar of 1.12 and 1.16 respectively, indicating single-transverse-mode fluorescence emission. Fluorescence output powers up to 0.3 mW have been observed from the ribs following excitation by a 3W multiline argon laser. The experimental fluorescence output levels for ribs with different size were in satisfactory agreement with theoretical calculations based on a plane wave analysis accounting for ground state depletion.
Grivas, Christos
7f564818-0ac0-4127-82a7-22e87ac35f1a
Shepherd, David
9fdd51c4-39d6-41b3-9021-4c033c2f4ead
May-Smith, Timothy
47952bbd-ce28-4507-a723-b4d80bf0f809
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Pollnau, M.
1094856b-791a-4050-98d9-c07777d5f0f5
Crunteanu, A.
fca22bc1-40b6-474f-8d0a-e1c1b9206b4c
Jelínek, M.
058ae7ba-cd86-4f99-990e-2e8f78cd4484
2003
Grivas, Christos
7f564818-0ac0-4127-82a7-22e87ac35f1a
Shepherd, David
9fdd51c4-39d6-41b3-9021-4c033c2f4ead
May-Smith, Timothy
47952bbd-ce28-4507-a723-b4d80bf0f809
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Pollnau, M.
1094856b-791a-4050-98d9-c07777d5f0f5
Crunteanu, A.
fca22bc1-40b6-474f-8d0a-e1c1b9206b4c
Jelínek, M.
058ae7ba-cd86-4f99-990e-2e8f78cd4484
Grivas, Christos, Shepherd, David, May-Smith, Timothy, Eason, R.W., Pollnau, M., Crunteanu, A. and Jelínek, M.
(2003)
Ti:sapphire rib waveguides as single-transverse-mode broadband fluorescence sources for optical coherence tomography applications.
Conference on Lasers and Electro-Optics/Europe (CLEO/Europe-EQEC 2003), Munich, Germany.
22 - 27 Jun 2003.
1 pp
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
Rib waveguides based on pulsed-laser-deposited Ti:sapphire thin films have been fabricated by Ar of 1.12 and 1.16 respectively, indicating single-transverse-mode fluorescence emission. Fluorescence output powers up to 0.3 mW have been observed from the ribs following excitation by a 3W multiline argon laser. The experimental fluorescence output levels for ribs with different size were in satisfactory agreement with theoretical calculations based on a plane wave analysis accounting for ground state depletion.
More information
Published date: 2003
Additional Information:
CG33 WED
Venue - Dates:
Conference on Lasers and Electro-Optics/Europe (CLEO/Europe-EQEC 2003), Munich, Germany, 2003-06-22 - 2003-06-27
Identifiers
Local EPrints ID: 41668
URI: http://eprints.soton.ac.uk/id/eprint/41668
PURE UUID: b4723cde-a85b-4dce-b9f5-615cd8e7f6d1
Catalogue record
Date deposited: 12 Oct 2006
Last modified: 16 Mar 2024 02:39
Export record
Contributors
Author:
Christos Grivas
Author:
David Shepherd
Author:
Timothy May-Smith
Author:
R.W. Eason
Author:
M. Pollnau
Author:
A. Crunteanu
Author:
M. Jelínek
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.