Pipe-clamping mattress to stop flowline walking
Pipe-clamping mattress to stop flowline walking
Thermal gradients from a heating front travelling down a flowline at start-up can cause a flowline to walk much like a worm creeps by repeated contractions and expansions of its body. To stop this for the Malampaya flowline, pipe-clamping mattresses (PCMs) were invented, developed, and deployed within a period of 12 months. The objective of this paper is to share the knowledge and experience from this novel but effective solution to mitigate pipeline walking. PCMs provide a cost-effective alternative to rockdump or conventional mattresses to axially restrain a pipeline at a location chosen so that the required restraint capacity is minimized. They are inspired by conventional mattresses and bear some similarity to them, but they are designed so that the weight of the mattress acts to clamp the pipeline with a high leverage. Thus 100% of the weight of the mattress is effective in generating axial friction with the seabed. This solution can be applied at any point along the line (chosen to minimize the required resistance) without requiring flanges or collars on the pipeline. From the most recent survey results 15 PCMs with a dry weight of around 9 tons per PCM, plus 7 tons for the logmat installed over every PCM appear to be effective to stop the walking of the Malampaya flowline. This performance is as expected from extensive analysis (FE and otherwise) to reproduce the observed walking behavior prior to restraining, to estimate the required restraint capacity, and to estimate the resistance provided by the PCMs. This paper describes the PCM, the clamping forces they generate by leveraging the weight of the PCM and logmats installed over them, and how the friction generated with the soil is estimated from interface shear tests on samples collected from the site, considering cyclic pore pressure generation and dissipation effects. It also briefly covers FE analyses to reproduce the observed walking behavior, and determine the required restraint capacity, the PCM fabrication, installation, and monitoring of the post-installation performance.
2669-2683
Offshore Technology Conference
Frankenmolen, Sebastiaan
d2965f2a-0ff2-4af2-9b44-01780d3ef3ff
Ang, Sze Yu
e9c67a13-cd74-4744-9712-8e386b14e8d8
Peek, Ralf
d67a02c7-b08e-453a-aa8e-2406cce42baf
Carr, Malcolm
a9cb00db-1d9d-40fb-af70-ff2de28ab657
MacRae, Ian
c1e2667c-b5a1-409c-9955-f1a4fe7f8069
White, David
a986033d-d26d-4419-a3f3-20dc54efce93
Rimmer, Jeffrey
e5bff301-729c-4523-a5b4-387fdb9c8db9
2017
Frankenmolen, Sebastiaan
d2965f2a-0ff2-4af2-9b44-01780d3ef3ff
Ang, Sze Yu
e9c67a13-cd74-4744-9712-8e386b14e8d8
Peek, Ralf
d67a02c7-b08e-453a-aa8e-2406cce42baf
Carr, Malcolm
a9cb00db-1d9d-40fb-af70-ff2de28ab657
MacRae, Ian
c1e2667c-b5a1-409c-9955-f1a4fe7f8069
White, David
a986033d-d26d-4419-a3f3-20dc54efce93
Rimmer, Jeffrey
e5bff301-729c-4523-a5b4-387fdb9c8db9
Frankenmolen, Sebastiaan, Ang, Sze Yu, Peek, Ralf, Carr, Malcolm, MacRae, Ian, White, David and Rimmer, Jeffrey
(2017)
Pipe-clamping mattress to stop flowline walking.
In Offshore Technology Conference, OTC 2017.
vol. 4,
Offshore Technology Conference.
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
Thermal gradients from a heating front travelling down a flowline at start-up can cause a flowline to walk much like a worm creeps by repeated contractions and expansions of its body. To stop this for the Malampaya flowline, pipe-clamping mattresses (PCMs) were invented, developed, and deployed within a period of 12 months. The objective of this paper is to share the knowledge and experience from this novel but effective solution to mitigate pipeline walking. PCMs provide a cost-effective alternative to rockdump or conventional mattresses to axially restrain a pipeline at a location chosen so that the required restraint capacity is minimized. They are inspired by conventional mattresses and bear some similarity to them, but they are designed so that the weight of the mattress acts to clamp the pipeline with a high leverage. Thus 100% of the weight of the mattress is effective in generating axial friction with the seabed. This solution can be applied at any point along the line (chosen to minimize the required resistance) without requiring flanges or collars on the pipeline. From the most recent survey results 15 PCMs with a dry weight of around 9 tons per PCM, plus 7 tons for the logmat installed over every PCM appear to be effective to stop the walking of the Malampaya flowline. This performance is as expected from extensive analysis (FE and otherwise) to reproduce the observed walking behavior prior to restraining, to estimate the required restraint capacity, and to estimate the resistance provided by the PCMs. This paper describes the PCM, the clamping forces they generate by leveraging the weight of the PCM and logmats installed over them, and how the friction generated with the soil is estimated from interface shear tests on samples collected from the site, considering cyclic pore pressure generation and dissipation effects. It also briefly covers FE analyses to reproduce the observed walking behavior, and determine the required restraint capacity, the PCM fabrication, installation, and monitoring of the post-installation performance.
This record has no associated files available for download.
More information
Published date: 2017
Venue - Dates:
Offshore Technology Conference, OTC 2017, , Houston, United States, 2017-05-01 - 2017-05-04
Identifiers
Local EPrints ID: 418153
URI: http://eprints.soton.ac.uk/id/eprint/418153
PURE UUID: 7eeb9492-d00b-4c33-9528-58bd9aac8a2d
Catalogue record
Date deposited: 22 Feb 2018 17:31
Last modified: 16 Mar 2024 04:32
Export record
Contributors
Author:
Sebastiaan Frankenmolen
Author:
Sze Yu Ang
Author:
Ralf Peek
Author:
Malcolm Carr
Author:
Ian MacRae
Author:
Jeffrey Rimmer
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics