Accompanying data to: X-ray computed micro-tomography of reticulated vitreous carbon
Accompanying data to: X-ray computed micro-tomography of reticulated vitreous carbon
Data sets supporting the research paper:
Luis F. Arenas, Richard P. Boardman, Carlos Ponce de León, Frank C. Walsh, X-ray computed micro-tomography of reticulated vitreous carbon, Carbon, 2018.
Data for Figure 8: Surface area per unit volume of different RVC grades. μCT data for all specimens obtained at a resolution of 9.6 μm per voxel, and additionally for RVC 100 ppi at 1.3 μm per voxel. Comparative data from SEM measurements [1,22] and pressure drop via the Ergun equation [3]. Linear fit for Friedrich’s A_e SEM data: y = 0.66x – 0.53 (R2 = 0.99). Linear fit for (underestimated) A_e by μCT at low resolution: y = 0.11x + 5.44 (R2 = 0.78).
Data for Figure 10: Distribution of the open-foam cell properties in 100 ppi RVC at a resampled resolution of 6 μm per voxel from a μ-CT scan: a) cell volume b) cell surface area. Both approximate to gamma distributions.
University of Southampton
Arenas Martinez, Luis Fernando
6e7e3d10-2aab-4fc3-a6d4-63a6614d0403
Boardman, Richard
5818d677-5732-4e8a-a342-7164dbb10df1
Ponce De Leon Albarran, Carlos
508a312e-75ff-4bcb-9151-dacc424d755c
Walsh, Frank
309528e7-062e-439b-af40-9309bc91efb2
Arenas Martinez, Luis Fernando
6e7e3d10-2aab-4fc3-a6d4-63a6614d0403
Boardman, Richard
5818d677-5732-4e8a-a342-7164dbb10df1
Ponce De Leon Albarran, Carlos
508a312e-75ff-4bcb-9151-dacc424d755c
Walsh, Frank
309528e7-062e-439b-af40-9309bc91efb2
Arenas Martinez, Luis Fernando and Boardman, Richard
(2018)
Accompanying data to: X-ray computed micro-tomography of reticulated vitreous carbon.
University of Southampton
doi:10.5258/SOTON/D0478
[Dataset]
Abstract
Data sets supporting the research paper:
Luis F. Arenas, Richard P. Boardman, Carlos Ponce de León, Frank C. Walsh, X-ray computed micro-tomography of reticulated vitreous carbon, Carbon, 2018.
Data for Figure 8: Surface area per unit volume of different RVC grades. μCT data for all specimens obtained at a resolution of 9.6 μm per voxel, and additionally for RVC 100 ppi at 1.3 μm per voxel. Comparative data from SEM measurements [1,22] and pressure drop via the Ergun equation [3]. Linear fit for Friedrich’s A_e SEM data: y = 0.66x – 0.53 (R2 = 0.99). Linear fit for (underestimated) A_e by μCT at low resolution: y = 0.11x + 5.44 (R2 = 0.78).
Data for Figure 10: Distribution of the open-foam cell properties in 100 ppi RVC at a resampled resolution of 6 μm per voxel from a μ-CT scan: a) cell volume b) cell surface area. Both approximate to gamma distributions.
Spreadsheet
Data_for_Figure_8.xlsx
- Dataset
Spreadsheet
Data_for_Figure_10.xlsx
- Dataset
More information
Published date: 5 April 2018
Organisations:
Energy Technology Group, Engineering Mats & Surface Engineerg Gp, Southampton Marine & Maritime Institute, Institute for Life Sciences
Identifiers
Local EPrints ID: 419124
URI: http://eprints.soton.ac.uk/id/eprint/419124
PURE UUID: ba25b79f-6d65-4498-b118-840ef46efb05
Catalogue record
Date deposited: 05 Apr 2018 16:31
Last modified: 08 Nov 2023 02:40
Export record
Altmetrics
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics