Non-invasive tests for the detection of oesophageal varices in compensated cirrhosis: systematic review and meta-analysis
Non-invasive tests for the detection of oesophageal varices in compensated cirrhosis: systematic review and meta-analysis
Introduction: Conclusive data on the accuracy and clinical applicability of non-invasive screening tests for oesophageal varices (OV) in patients with compensated cirrhosis remain lacking. We conducted this study to identify currently available tests, estimate their diagnostic performance and then exemplify how these could be utilized in clinical practice. Materials and methods: A systematic literature search was performed to identify all primary studies that reported accuracy using oesophagogastroduodenoscopy (OGD) as the gold standard. Sources searched included Ovid MEDLINE, Ovid EMBASE and The Cochrane Library databases. Results: Twenty-one studies with a total of 2471 patients were identified. Several tests were evaluated in more than three studies. Platelet count/spleen diameter ratio (PSR) had the highest summary area under the curve for detection of any size OV of 0.85 (95% confidence interval 0.78–0.92). At a cut-off of 909 (n = 4 studies) and prevalence rates of 10, 20, 30, 40 and 50% for OV, PSR screening correctly avoided the need for OGD in 70, 62, 55, 47 and 39% of patients, respectively. Conclusions: PSR appears to be the most accurate and validated non-invasive screening test for OV in patients with compensated cirrhosis. At a cut-off of 909, PSR could be clinically useful to avoid OGDs in a significant proportion of patients.
Diagnosis; non-invasive markers; platelet to spleen ratio; liver stiffness measurement
Sami, Sarmed S.
93469bbd-03c0-4c39-b1ab-af7ef22bfa47
Harman, David
ae7b8c20-15e8-4358-b520-560b0f32d553
Ragunath, Krish
797b7a11-576f-41ff-a9c2-85585bd99339
Böhning, Dankmar
e59cede5-81be-4dfa-afec-0e81ac3b7f6c
Parkes, Julie
59dc6de3-4018-415e-bb99-13552f97e984
Guha, Indra Neil
a3dddb81-7413-4309-b85d-afa33b8d3fce
Sami, Sarmed S.
93469bbd-03c0-4c39-b1ab-af7ef22bfa47
Harman, David
ae7b8c20-15e8-4358-b520-560b0f32d553
Ragunath, Krish
797b7a11-576f-41ff-a9c2-85585bd99339
Böhning, Dankmar
e59cede5-81be-4dfa-afec-0e81ac3b7f6c
Parkes, Julie
59dc6de3-4018-415e-bb99-13552f97e984
Guha, Indra Neil
a3dddb81-7413-4309-b85d-afa33b8d3fce
Sami, Sarmed S., Harman, David, Ragunath, Krish, Böhning, Dankmar, Parkes, Julie and Guha, Indra Neil
(2018)
Non-invasive tests for the detection of oesophageal varices in compensated cirrhosis: systematic review and meta-analysis.
United European Gastroenterology Journal.
(doi:10.1177/2050640618767604).
Abstract
Introduction: Conclusive data on the accuracy and clinical applicability of non-invasive screening tests for oesophageal varices (OV) in patients with compensated cirrhosis remain lacking. We conducted this study to identify currently available tests, estimate their diagnostic performance and then exemplify how these could be utilized in clinical practice. Materials and methods: A systematic literature search was performed to identify all primary studies that reported accuracy using oesophagogastroduodenoscopy (OGD) as the gold standard. Sources searched included Ovid MEDLINE, Ovid EMBASE and The Cochrane Library databases. Results: Twenty-one studies with a total of 2471 patients were identified. Several tests were evaluated in more than three studies. Platelet count/spleen diameter ratio (PSR) had the highest summary area under the curve for detection of any size OV of 0.85 (95% confidence interval 0.78–0.92). At a cut-off of 909 (n = 4 studies) and prevalence rates of 10, 20, 30, 40 and 50% for OV, PSR screening correctly avoided the need for OGD in 70, 62, 55, 47 and 39% of patients, respectively. Conclusions: PSR appears to be the most accurate and validated non-invasive screening test for OV in patients with compensated cirrhosis. At a cut-off of 909, PSR could be clinically useful to avoid OGDs in a significant proportion of patients.
Text
NoninvasiveTests
- Accepted Manuscript
More information
Accepted/In Press date: 27 February 2018
e-pub ahead of print date: 22 March 2018
Keywords:
Diagnosis; non-invasive markers; platelet to spleen ratio; liver stiffness measurement
Identifiers
Local EPrints ID: 419959
URI: http://eprints.soton.ac.uk/id/eprint/419959
ISSN: 2050-6406
PURE UUID: 4bfd7d63-bb86-4c35-9af7-69a9abfcc3f5
Catalogue record
Date deposited: 24 Apr 2018 16:30
Last modified: 16 Mar 2024 03:02
Export record
Altmetrics
Contributors
Author:
Sarmed S. Sami
Author:
David Harman
Author:
Krish Ragunath
Author:
Dankmar Böhning
Author:
Indra Neil Guha
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics