Abdominal muscle size and symmetry in normal subjects
Abdominal muscle size and symmetry in normal subjects
This study was undertaken to establish normal reference ranges for abdominal muscle size and symmetry and to examine the effects on these of gender and age. We studied 123 subjects, consisting of 55 men (aged 21-72 years) and 68 women (aged 20-64 years). Real-time ultrasound imaging of the abdominal muscles was performed. Thickness of internal and external oblique (IO, EO), transversus abdominis (TA), and rectus abdominis (RA), and cross-sectional area (CSA) of RA were measured, and absolute and relative muscle thickness (percent total muscle thickness), order of thickness, and symmetry (percent difference between sides) were determined. Males had significantly larger muscles than females and size was poorly correlated with age. The pattern of relative muscle thickness was RA > IO > EO > TA. Symmetry for total absolute thickness of all three lateral muscles was 8%-9% (mean) but for individual muscles there was asymmetry of absolute size (13%-24%), whereas relative thickness was symmetrical for all muscles. These findings provide robust reference data for the abdominal muscles in normal males and females in order to enable comparison with clinical groups to assess abnormalities and establish sensitivity for evaluating the effectiveness of interventions.
320-326
Rankin, Gabrielle
b76d6bc7-ce92-46bc-987a-26d73a1187f3
Stokes, Maria
71730503-70ce-4e67-b7ea-a3e54579717f
Newham, Dianne J.
437fa944-e15a-49a0-8763-e65ab086c457
1 September 2006
Rankin, Gabrielle
b76d6bc7-ce92-46bc-987a-26d73a1187f3
Stokes, Maria
71730503-70ce-4e67-b7ea-a3e54579717f
Newham, Dianne J.
437fa944-e15a-49a0-8763-e65ab086c457
Rankin, Gabrielle, Stokes, Maria and Newham, Dianne J.
(2006)
Abdominal muscle size and symmetry in normal subjects.
Muscle & Nerve, 34 (3), .
(doi:10.1002/mus.20589).
Abstract
This study was undertaken to establish normal reference ranges for abdominal muscle size and symmetry and to examine the effects on these of gender and age. We studied 123 subjects, consisting of 55 men (aged 21-72 years) and 68 women (aged 20-64 years). Real-time ultrasound imaging of the abdominal muscles was performed. Thickness of internal and external oblique (IO, EO), transversus abdominis (TA), and rectus abdominis (RA), and cross-sectional area (CSA) of RA were measured, and absolute and relative muscle thickness (percent total muscle thickness), order of thickness, and symmetry (percent difference between sides) were determined. Males had significantly larger muscles than females and size was poorly correlated with age. The pattern of relative muscle thickness was RA > IO > EO > TA. Symmetry for total absolute thickness of all three lateral muscles was 8%-9% (mean) but for individual muscles there was asymmetry of absolute size (13%-24%), whereas relative thickness was symmetrical for all muscles. These findings provide robust reference data for the abdominal muscles in normal males and females in order to enable comparison with clinical groups to assess abnormalities and establish sensitivity for evaluating the effectiveness of interventions.
This record has no associated files available for download.
More information
Published date: 1 September 2006
Identifiers
Local EPrints ID: 42007
URI: http://eprints.soton.ac.uk/id/eprint/42007
ISSN: 0148-639X
PURE UUID: 83589eed-620b-40ec-9f25-4264f64ff225
Catalogue record
Date deposited: 30 Oct 2006
Last modified: 16 Mar 2024 03:30
Export record
Altmetrics
Contributors
Author:
Gabrielle Rankin
Author:
Dianne J. Newham
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics