READ ME File For 'Pressure characterisation Data 180118NB318-2-chip2-27-500um'
License: Attribution-NonCommercial 4.0 International

Dataset DOI: 10.5258/SOTON/D0569

ReadMe Author: Alexander Jantzen, University of Southampton
Email: A.jantzen@soton.ac.uk
Department: Optoelectronics Research Centre
Industrial Sponsor: Parker Aerospace
Supervisor: Prof. Peter G. R. Smith

This dataset supports the publication:
AUTHORS: Jantzen, A., Gow, P. C., Gray, A., Scholl, S., Gates, J., Smith, P., Boyd, L. & Holmes, C.
TITLE: Pressure Sensing Based on Ratiometric Bragg Grating Loss in a Planar Silica Diaphragm Platform
JOURNAL: Advanced Photonics Congress JTu2A.62 
PAPER DOI IF KNOWN

Data was collected from an ANDO AQ6317B optical spectrum analyser using a Amonics ASLD-CWDM-5B-FA source. Pressure readings were recorded manually using a vacuum gauge.
This dataset contains:wavelength data (nm) and intensity data (dBm)

Data supporting etc etc 

The figures are as follows:

Fig. 2  Left axis shows the amplitude ratio of grating #2, the reference, and #3, the measurand, normalized to the zero differential
pressure point. Right axis shows the wavelength shift of the #3 Bragg grating peak with an increase in pressure.


Date of data collection: 18 January 2018

Information about geographic location of data collection: University of Southampton, U.K.

Funding. Engineering and Physical Sciences Research Council (EPSRC) (EP/M508147/1, EP/K034480/1, EP/
M024539/1, EP/M013243/1, EP/M013294/1); 
Fluid Systems Division of Parker Aerospace, Parker Hannifin Corporation (CASE award PhD).

Pressure readings were respectively: 2	24	23.5	23	22.5	22	21.5	21	20	19	18	17	16	15	14	13	12	11	10	9	8	7	6	5	4	3	2.5 with an error of 0.25 in Hg. The reading to begin with is the offset value of the gauge.

Date that the file was created: December 2017