The University of Southampton
University of Southampton Institutional Repository

Effect of contact location on vibrotactile thresholds at the fingertip

Effect of contact location on vibrotactile thresholds at the fingertip
Effect of contact location on vibrotactile thresholds at the fingertip
Vibrotactile thresholds depend on the characteristics of the vibration, the location of contact with the skin, and the geometry of the contact with the skin. This experimental study investigated vibrotactile thresholds (from 8 to 250?Hz) at five locations on the distal phalanx of the finger with two contactors: (i) a 1-mm diameter circular probe (0.78-mm2 area) with a 1-mm gap to a fixed circular surround (i.e., 7.1-mm2 excitation area), and (ii) a 6-mm diameter circular probe (28-mm2 area) with a 2-mm gap to a fixed circular surround (i.e., 79-mm2 excitation area). With both contactors, especially the smaller contactor at low frequencies (i.e., 8, 16, and 31.5?Hz), thresholds decreased towards the tip of the finger, although there was little variation around the whorl. With low frequencies of vibration, and at all five locations on the finger, similar thresholds were obtained with both contactors, consistent with the NPI channel not changing in sensitivity with a change in the area of stimulation. At high frequencies (i.e., 63, 125, and 250?Hz), thresholds were lower with the larger area of stimulation at all locations, except at the extreme tip of the finger, consistent with spatial summation in the Pacinian channel. It is concluded that with a 6-mm diameter contactor, moderate variations in location around the whorl have little influence on the measured thresholds. With the 1-mm diameter contactor there were greater variations in thresholds and extreme locations, near the nail and the distal interphalangeal joint, may be unsuitable for investigating sensorineural disorders.
vibration, thresholds, tactile channel, mechanoreceptor, fingertip
0899-0220
73-81
Whitehouse, Darren J.
a54f52f0-b41c-4e52-841a-df50987df887
Morioka, Miyuki
8eb26aca-8773-4e45-8737-61c2438d30d9
Griffin, Michael J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Whitehouse, Darren J.
a54f52f0-b41c-4e52-841a-df50987df887
Morioka, Miyuki
8eb26aca-8773-4e45-8737-61c2438d30d9
Griffin, Michael J.
24112494-9774-40cb-91b7-5b4afe3c41b8

Whitehouse, Darren J., Morioka, Miyuki and Griffin, Michael J. (2006) Effect of contact location on vibrotactile thresholds at the fingertip. Somatosensory & Motor Research, 23 (1/2), 73-81. (doi:10.1080/08990220600741119).

Record type: Article

Abstract

Vibrotactile thresholds depend on the characteristics of the vibration, the location of contact with the skin, and the geometry of the contact with the skin. This experimental study investigated vibrotactile thresholds (from 8 to 250?Hz) at five locations on the distal phalanx of the finger with two contactors: (i) a 1-mm diameter circular probe (0.78-mm2 area) with a 1-mm gap to a fixed circular surround (i.e., 7.1-mm2 excitation area), and (ii) a 6-mm diameter circular probe (28-mm2 area) with a 2-mm gap to a fixed circular surround (i.e., 79-mm2 excitation area). With both contactors, especially the smaller contactor at low frequencies (i.e., 8, 16, and 31.5?Hz), thresholds decreased towards the tip of the finger, although there was little variation around the whorl. With low frequencies of vibration, and at all five locations on the finger, similar thresholds were obtained with both contactors, consistent with the NPI channel not changing in sensitivity with a change in the area of stimulation. At high frequencies (i.e., 63, 125, and 250?Hz), thresholds were lower with the larger area of stimulation at all locations, except at the extreme tip of the finger, consistent with spatial summation in the Pacinian channel. It is concluded that with a 6-mm diameter contactor, moderate variations in location around the whorl have little influence on the measured thresholds. With the 1-mm diameter contactor there were greater variations in thresholds and extreme locations, near the nail and the distal interphalangeal joint, may be unsuitable for investigating sensorineural disorders.

This record has no associated files available for download.

More information

Published date: 2006
Keywords: vibration, thresholds, tactile channel, mechanoreceptor, fingertip
Organisations: Human Sciences Group

Identifiers

Local EPrints ID: 42190
URI: http://eprints.soton.ac.uk/id/eprint/42190
ISSN: 0899-0220
PURE UUID: 7d2bcd58-2a8b-4042-a7f0-f1258ac54c5d
ORCID for Michael J. Griffin: ORCID iD orcid.org/0000-0003-0743-9502

Catalogue record

Date deposited: 23 Nov 2006
Last modified: 15 Mar 2024 08:46

Export record

Altmetrics

Contributors

Author: Darren J. Whitehouse
Author: Miyuki Morioka
Author: Michael J. Griffin ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×