Erratum: “Cavity enhanced third harmonic generation in graphene” [Appl. Phys. Lett. 112, 011102 (2018)]

Erratum: “Cavity enhanced third harmonic generation in graphene” [Appl. Phys. Lett. 112, 011102 (2018)]
Erratum: “Cavity enhanced third harmonic generation in graphene” [Appl. Phys. Lett. 112, 011102 (2018)]

In the paper "Cavity enhanced third harmonic generation in graphene," we reported third harmonic generation from a graphene-dielectric-metal cavity. Since the original publication, it has come to light that a rather severe error was made in the calibration of the detector used in the experiments. Correcting this error (see corrected Figs. 1 and 2) leads to significantly lower absolute powers than previously reported, and power conversion efficiencies approaching ∼10-8 (for the largest powers used in the experiment) when resonant with the cavity and ∼10-10 when off resonance. The off resonance conversion efficiency is in line with previously reported values for planar graphene measured with comparable pulse fluence.1 Note that, due to a miscommunication between the authors, this error did not propagate into the numerical modeling results from the paper, i.e., our pW output powers are in line with v3 of order 10-17 m2=V2, as found in the analytical modeling of Ref. 2. It should also be noted that the main conclusion of our original paper, i.e., a two orders of magnitude enhancement in the harmonic generation due to the cavity, is unaffected by this error. (Figure Presented).

0003-6951
1-2
Beckerleg, Chris
1dfb65c8-f95c-44c7-8814-4bfb2957ddc9
Constant, Thomas J.
629eb6b0-91fb-40f4-8b6e-d0f649df24bd
Zeimpekis, Ioannis
a2c354ec-3891-497c-adac-89b3a5d96af0
Hornett, Samuel M.
0fc76e6d-9e13-4b3f-9a0a-50b7771412f7
Craig, Chris
2328b42b-552e-4a82-941d-45449e952f10
Hewak, Daniel W.
87c80070-c101-4f7a-914f-4cc3131e3db0
Hendry, Euan
15b0b014-414d-41bb-ad85-1e1808525d94
Beckerleg, Chris
1dfb65c8-f95c-44c7-8814-4bfb2957ddc9
Constant, Thomas J.
629eb6b0-91fb-40f4-8b6e-d0f649df24bd
Zeimpekis, Ioannis
a2c354ec-3891-497c-adac-89b3a5d96af0
Hornett, Samuel M.
0fc76e6d-9e13-4b3f-9a0a-50b7771412f7
Craig, Chris
2328b42b-552e-4a82-941d-45449e952f10
Hewak, Daniel W.
87c80070-c101-4f7a-914f-4cc3131e3db0
Hendry, Euan
15b0b014-414d-41bb-ad85-1e1808525d94

Beckerleg, Chris, Constant, Thomas J., Zeimpekis, Ioannis, Hornett, Samuel M., Craig, Chris, Hewak, Daniel W. and Hendry, Euan (2018) Erratum: “Cavity enhanced third harmonic generation in graphene” [Appl. Phys. Lett. 112, 011102 (2018)]. Applied Physics Letters, 112 (26), 1-2, [269901]. (doi:10.1063/1.5028369).

Record type: Letter

Abstract

In the paper "Cavity enhanced third harmonic generation in graphene," we reported third harmonic generation from a graphene-dielectric-metal cavity. Since the original publication, it has come to light that a rather severe error was made in the calibration of the detector used in the experiments. Correcting this error (see corrected Figs. 1 and 2) leads to significantly lower absolute powers than previously reported, and power conversion efficiencies approaching ∼10-8 (for the largest powers used in the experiment) when resonant with the cavity and ∼10-10 when off resonance. The off resonance conversion efficiency is in line with previously reported values for planar graphene measured with comparable pulse fluence.1 Note that, due to a miscommunication between the authors, this error did not propagate into the numerical modeling results from the paper, i.e., our pW output powers are in line with v3 of order 10-17 m2=V2, as found in the analytical modeling of Ref. 2. It should also be noted that the main conclusion of our original paper, i.e., a two orders of magnitude enhancement in the harmonic generation due to the cavity, is unaffected by this error. (Figure Presented).

This record has no associated files available for download.

More information

Accepted/In Press date: June 2018
e-pub ahead of print date: 28 June 2018
Published date: June 2018

Identifiers

Local EPrints ID: 422634
URI: http://eprints.soton.ac.uk/id/eprint/422634
ISSN: 0003-6951
PURE UUID: c0d51945-5c2c-45c6-ae8d-ed50ceb2e4eb
ORCID for Ioannis Zeimpekis: ORCID iD orcid.org/0000-0002-7455-1599
ORCID for Chris Craig: ORCID iD orcid.org/0000-0001-6919-4294
ORCID for Daniel W. Hewak: ORCID iD orcid.org/0000-0002-2093-5773

Catalogue record

Date deposited: 27 Jul 2018 16:30
Last modified: 16 Mar 2024 04:10

Export record

Altmetrics

Contributors

Author: Chris Beckerleg
Author: Thomas J. Constant
Author: Samuel M. Hornett
Author: Chris Craig ORCID iD
Author: Daniel W. Hewak ORCID iD
Author: Euan Hendry

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×