Localization accuracy in single molecule microscopy using electron-multiplying charge-coupled device cameras
Localization accuracy in single molecule microscopy using electron-multiplying charge-coupled device cameras
The electron-multiplying charge-coupled device (EMCCD) is a popular technology for imaging under extremely low light conditions. It has become widely used, for example, in single molecule microscopy experiments where few photons can be detected from the individual molecules of interest. Despite its important role in low light microscopy, however, little has been done in the way of determining how accurately parameters of interest (e.g., location of a single molecule) can be estimated from an image that it produces. Here, we develop the theory for calculating the Fisher information matrix, and hence the Cramer-Rao lower bound-based limit of the accuracy, for estimating parameters from an EMCCD image. An EMCCD operates by amplifying a weak signal that would otherwise be drowned out by the detector's readout noise as in the case of a conventional charge-coupled device (CCD). The signal amplification is a stochastic electron multiplication process, and is modeled here as a geometrically multiplied branching process. In developing our theory, we also introduce a "noise coefficient" which enables the comparison of the Fisher information of different data models via a scalar quantity. This coefficient importantly allows the selection of the best detector (e.g., EMCCD or CCD), based on factors such as the signal level, and regardless of the specific estimation problem at hand. We apply our theory to the problem of localizing a single molecule, and compare the calculated limits of the localization accuracy with the standard deviations of maximum likelihood location estimates obtained from simulated images of a single molecule.
Branching process, Cramer-Rao lower bound, electron multiplication, Fisher information matrix, single molecule microscopy
Chao, Jerry
550e20b0-8365-42e3-a6fc-1048eb8c2e47
Ward, E. Sally
b31c0877-8abe-485f-b800-244a9d3cd6cc
Ober, Raimund J.
31f4d47f-fb49-44f5-8ff6-87fc4aff3d36
12 February 2012
Chao, Jerry
550e20b0-8365-42e3-a6fc-1048eb8c2e47
Ward, E. Sally
b31c0877-8abe-485f-b800-244a9d3cd6cc
Ober, Raimund J.
31f4d47f-fb49-44f5-8ff6-87fc4aff3d36
Chao, Jerry, Ward, E. Sally and Ober, Raimund J.
(2012)
Localization accuracy in single molecule microscopy using electron-multiplying charge-coupled device cameras.
In Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XIX.
vol. 8227,
SPIE..
(doi:10.1117/12.908951).
Record type:
Conference or Workshop Item
(Paper)
Abstract
The electron-multiplying charge-coupled device (EMCCD) is a popular technology for imaging under extremely low light conditions. It has become widely used, for example, in single molecule microscopy experiments where few photons can be detected from the individual molecules of interest. Despite its important role in low light microscopy, however, little has been done in the way of determining how accurately parameters of interest (e.g., location of a single molecule) can be estimated from an image that it produces. Here, we develop the theory for calculating the Fisher information matrix, and hence the Cramer-Rao lower bound-based limit of the accuracy, for estimating parameters from an EMCCD image. An EMCCD operates by amplifying a weak signal that would otherwise be drowned out by the detector's readout noise as in the case of a conventional charge-coupled device (CCD). The signal amplification is a stochastic electron multiplication process, and is modeled here as a geometrically multiplied branching process. In developing our theory, we also introduce a "noise coefficient" which enables the comparison of the Fisher information of different data models via a scalar quantity. This coefficient importantly allows the selection of the best detector (e.g., EMCCD or CCD), based on factors such as the signal level, and regardless of the specific estimation problem at hand. We apply our theory to the problem of localizing a single molecule, and compare the calculated limits of the localization accuracy with the standard deviations of maximum likelihood location estimates obtained from simulated images of a single molecule.
This record has no associated files available for download.
More information
Published date: 12 February 2012
Venue - Dates:
Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XIX, , San Francisco, CA, United States, 2012-01-24 - 2012-01-26
Keywords:
Branching process, Cramer-Rao lower bound, electron multiplication, Fisher information matrix, single molecule microscopy
Identifiers
Local EPrints ID: 423633
URI: http://eprints.soton.ac.uk/id/eprint/423633
PURE UUID: 103bd87d-5733-4f3f-b585-0c88e2189e3e
Catalogue record
Date deposited: 27 Sep 2018 16:30
Last modified: 16 Mar 2024 04:37
Export record
Altmetrics
Contributors
Author:
Jerry Chao
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics