The University of Southampton
University of Southampton Institutional Repository

How accurately can a single molecule be localized when imaged through an optical microscope?

How accurately can a single molecule be localized when imaged through an optical microscope?
How accurately can a single molecule be localized when imaged through an optical microscope?

We present a simple analytical expression for the fundamental limit to the accuracy with which the location of a single molecule can be determined that is imaged through an optical microscope. This expression depends on the optical properties of the microscope and the photophysical properties of the single molecule. We also show how the fundamental limit is deteriorated by factors like pixelation of the detector and noise sources in the detection system. The present results gives an experimenter insight into what is achievable in an optical microscope and provide guidelines for experimental design.

1087-1090
IEEE
Ram, Sripad
559bd560-3817-4e53-8c7a-2f08e4518412
Ward, E. Sally
b31c0877-8abe-485f-b800-244a9d3cd6cc
Ober, Raimund J.
31f4d47f-fb49-44f5-8ff6-87fc4aff3d36
Ram, Sripad
559bd560-3817-4e53-8c7a-2f08e4518412
Ward, E. Sally
b31c0877-8abe-485f-b800-244a9d3cd6cc
Ober, Raimund J.
31f4d47f-fb49-44f5-8ff6-87fc4aff3d36

Ram, Sripad, Ward, E. Sally and Ober, Raimund J. (2004) How accurately can a single molecule be localized when imaged through an optical microscope? In 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano. vol. 2, IEEE. pp. 1087-1090 .

Record type: Conference or Workshop Item (Paper)

Abstract

We present a simple analytical expression for the fundamental limit to the accuracy with which the location of a single molecule can be determined that is imaged through an optical microscope. This expression depends on the optical properties of the microscope and the photophysical properties of the single molecule. We also show how the fundamental limit is deteriorated by factors like pixelation of the detector and noise sources in the detection system. The present results gives an experimenter insight into what is achievable in an optical microscope and provide guidelines for experimental design.

This record has no associated files available for download.

More information

Published date: 2004
Venue - Dates: 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano, , Arlington, VA, United States, 2004-04-15 - 2004-04-18

Identifiers

Local EPrints ID: 424086
URI: http://eprints.soton.ac.uk/id/eprint/424086
PURE UUID: 2de8772d-0470-40c1-b7ad-183e2686650b
ORCID for E. Sally Ward: ORCID iD orcid.org/0000-0003-3232-7238
ORCID for Raimund J. Ober: ORCID iD orcid.org/0000-0002-1290-7430

Catalogue record

Date deposited: 04 Oct 2018 16:30
Last modified: 06 Jun 2024 02:04

Export record

Contributors

Author: Sripad Ram
Author: E. Sally Ward ORCID iD
Author: Raimund J. Ober ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×