Evaluation of reconstruction and segmentation techniques on high temporal resolution μCT scans for geotechnical applications
Evaluation of reconstruction and segmentation techniques on high temporal resolution μCT scans for geotechnical applications
Coupled hydro-thermal phenomena are often relevant to applications in energy geotechnics, such as nuclear waste disposal and ground heat storage or transfer. It is then necessary to obtain data for use in and validation of models. Micro-focus X-ray computed tomography (μCT) has the potential to investigate hydro-thermal phenomena, both qualitatively and quantitatively. However it is difficult to obtain representative CT scan data for dynamic processes as a compromise must be made between image quality and scan time. For example, in thermally-driven water flow, moisture migration in the pore space could occur rapidly and over the course of a single scan. Reducing the scan time to obtain representative temporal data leads to a different set of challenges in terms of image quality and data processing. This paper investigates the potential of algebraic reconstruction techniques (ART) to improve the quality of reconstructed images from fast undersampled scans or noisy projection data, with reference to a uniformly-graded dry sand specimen. Results using ART are compared with those obtained using data reconstructed by the conventional filtered back-projection technique (FBP). In both cases, phase proportions are determined by Gaussian decomposition (GD) rather than traditional thresholding methods. It is shown that there is no need to attempt to improve the image quality by altering the image reconstruction algorithm, because GD is tolerant of undersampling and noisy data.
284-290
Liu, K.
eeadfb38-005d-45a0-bb01-8b8eb734918b
Loveridge, F. A.
fb5b7ad9-d1b8-40d3-894b-bccedf0e8a77
Boardman, R.
5818d677-5732-4e8a-a342-7164dbb10df1
Powrie, W.
600c3f02-00f8-4486-ae4b-b4fc8ec77c3c
2018
Liu, K.
eeadfb38-005d-45a0-bb01-8b8eb734918b
Loveridge, F. A.
fb5b7ad9-d1b8-40d3-894b-bccedf0e8a77
Boardman, R.
5818d677-5732-4e8a-a342-7164dbb10df1
Powrie, W.
600c3f02-00f8-4486-ae4b-b4fc8ec77c3c
Liu, K., Loveridge, F. A., Boardman, R. and Powrie, W.
(2018)
Evaluation of reconstruction and segmentation techniques on high temporal resolution μCT scans for geotechnical applications.
Ferrari, A. and Laloui, L.
(eds.)
In Energy Geotechnics: SEG 2018.
Springer.
.
(doi:10.1007/978-3-319-99670-7_36).
Record type:
Conference or Workshop Item
(Paper)
Abstract
Coupled hydro-thermal phenomena are often relevant to applications in energy geotechnics, such as nuclear waste disposal and ground heat storage or transfer. It is then necessary to obtain data for use in and validation of models. Micro-focus X-ray computed tomography (μCT) has the potential to investigate hydro-thermal phenomena, both qualitatively and quantitatively. However it is difficult to obtain representative CT scan data for dynamic processes as a compromise must be made between image quality and scan time. For example, in thermally-driven water flow, moisture migration in the pore space could occur rapidly and over the course of a single scan. Reducing the scan time to obtain representative temporal data leads to a different set of challenges in terms of image quality and data processing. This paper investigates the potential of algebraic reconstruction techniques (ART) to improve the quality of reconstructed images from fast undersampled scans or noisy projection data, with reference to a uniformly-graded dry sand specimen. Results using ART are compared with those obtained using data reconstructed by the conventional filtered back-projection technique (FBP). In both cases, phase proportions are determined by Gaussian decomposition (GD) rather than traditional thresholding methods. It is shown that there is no need to attempt to improve the image quality by altering the image reconstruction algorithm, because GD is tolerant of undersampling and noisy data.
Text
Liu2019_Chapter_EvaluationOfReconstructionAndS
Restricted to Repository staff only
Request a copy
More information
e-pub ahead of print date: 9 January 2018
Published date: 2018
Identifiers
Local EPrints ID: 425591
URI: http://eprints.soton.ac.uk/id/eprint/425591
ISSN: 1866-8755
PURE UUID: a423be86-8f8e-4696-92e5-ecbc7e2e959a
Catalogue record
Date deposited: 25 Oct 2018 16:30
Last modified: 16 Mar 2024 03:36
Export record
Altmetrics
Contributors
Author:
K. Liu
Editor:
A. Ferrari
Editor:
L. Laloui
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics