The purpose of this paper is to explore both an extended and a reduced set of input parameters of the Finite Element (FE) model of the human lower limb with a Total Knee Replacement (TKR) implant. The most influential parameters in determining the size and the shape of the performance envelopes of eight kinematics and peak contact pressure output variables of the tibio-femoral joint and the patello-femoral joint are sought. The lower limb FE model, which includes bones, TKR implant, soft tissues and applied forces of realistic size, is used in the context of the stair ascent simulation. Two probabilistic methods are used together with the FE model to generate the performance envelopes and to explore the sensitivities of the input parameters of the FE model: the Monte Carlo simulation and the Response Surface Method (RSM). A total of four probabilistic FE analyses assess how the uncertainties in an extended set of 77 input variables and a reduced set of 22 input variables obtained from the RSM/sensitivity analyses affect the performance envelopes. It is shown that the FE model with the reduced set of variables is able to replicate the full FE model. The differences between the Monte Carlo envelopes of performance obtained with the FE model with the full set of variables and the FE model with the reduced set of variables were on average over all output measures under 1.67 mm for translations, 1.75° for rotations and under 2 MPa for peak contact pressures. The differences between the RSM and the Monte Carlo envelopes of performances obtained with the reduced set of input variables were, on average, over all output measures under 0.75 mm for translations, 1.26° for rotations and 2.39 MPa for peak contact pressures. While saving computational time with the reduced set of variables, the findings are especially of high importance to the orthopedic surgeons who would like to know the most important parameters that can influence the performance of the TKR for a given human activity.
1116-1132
Arsene, C.T.C.
827ee4a7-cf87-4fce-a551-6fe7ec22af49
Gabrys, B.
220ebf7f-0457-4667-9fbc-532bca3455cf
1 August 2013
Arsene, C.T.C.
827ee4a7-cf87-4fce-a551-6fe7ec22af49
Gabrys, B.
220ebf7f-0457-4667-9fbc-532bca3455cf
Arsene, C.T.C. and Gabrys, B.
(2013)
Probabilistic finite element predictions of the human lower limb model in total knee replacement.
Medical Engineering & Physics, 35 (8), .
(doi:10.1016/j.medengphy.2012.11.011).
Abstract
The purpose of this paper is to explore both an extended and a reduced set of input parameters of the Finite Element (FE) model of the human lower limb with a Total Knee Replacement (TKR) implant. The most influential parameters in determining the size and the shape of the performance envelopes of eight kinematics and peak contact pressure output variables of the tibio-femoral joint and the patello-femoral joint are sought. The lower limb FE model, which includes bones, TKR implant, soft tissues and applied forces of realistic size, is used in the context of the stair ascent simulation. Two probabilistic methods are used together with the FE model to generate the performance envelopes and to explore the sensitivities of the input parameters of the FE model: the Monte Carlo simulation and the Response Surface Method (RSM). A total of four probabilistic FE analyses assess how the uncertainties in an extended set of 77 input variables and a reduced set of 22 input variables obtained from the RSM/sensitivity analyses affect the performance envelopes. It is shown that the FE model with the reduced set of variables is able to replicate the full FE model. The differences between the Monte Carlo envelopes of performance obtained with the FE model with the full set of variables and the FE model with the reduced set of variables were on average over all output measures under 1.67 mm for translations, 1.75° for rotations and under 2 MPa for peak contact pressures. The differences between the RSM and the Monte Carlo envelopes of performances obtained with the reduced set of input variables were, on average, over all output measures under 0.75 mm for translations, 1.26° for rotations and 2.39 MPa for peak contact pressures. While saving computational time with the reduced set of variables, the findings are especially of high importance to the orthopedic surgeons who would like to know the most important parameters that can influence the performance of the TKR for a given human activity.
This record has no associated files available for download.
More information
Accepted/In Press date: 30 November 2012
e-pub ahead of print date: 10 January 2013
Published date: 1 August 2013
Identifiers
Local EPrints ID: 427000
URI: http://eprints.soton.ac.uk/id/eprint/427000
ISSN: 1350-4533
PURE UUID: bfac09e6-6f1f-45a0-b5ad-2797e1ce9e67
Catalogue record
Date deposited: 20 Dec 2018 17:30
Last modified: 15 Mar 2024 23:29
Export record
Altmetrics
Contributors
Author:
C.T.C. Arsene
Author:
B. Gabrys
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics