The repeatability of cerebral autoregulation assessment using sinusoidal lower body negative pressure
The repeatability of cerebral autoregulation assessment using sinusoidal lower body negative pressure
A forced periodic variation in blood pressure produces a similar variation in cerebral blood velocity. The amplitudes and phases of the pressure and velocity waveforms are indicative of the dynamic response of the cerebral autoregulation. The phase of the velocity leads the pressure; the greater the phase difference the faster the autoregulation response. Various techniques have been employed to oscillate arterial blood pressure but measurement reproducibility has been poor. The purpose of this study was to assess the reproducibility of phase measurements when sinusoidal lower body negative pressure is used to vary blood pressure. Five healthy volunteers were assessed at two vacuum levels on each of eight visits. For each measurement a 12 s sinusoidal cycle was maintained for 5 min. The Fourier components of blood pressure and the middle cerebral artery velocity were determined at the oscillation frequency. The phase of velocity consistently led the pressure. The mean phase difference was 42+/-13 degrees for the stronger vacuum and 36+/-42 degrees for the weaker vacuum. The variation given is the within-subjects standard deviation estimated from a one-way analysis of variance. Sinusoidal lower body negative pressure is a useful stimulus for investigating autoregulation; it has advantages over other methods. High vacuums show good reproducibility but are too uncomfortable for patient use.
Adult, Blood Pressure, Blood Pressure Determination, Carbon Dioxide, Cerebrovascular Circulation, Female, Heart Rate, Homeostasis, Humans, Laser-Doppler Flowmetry, Lower Body Negative Pressure, Male, Middle Aged, Reference Values, Reproducibility of Results, Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't
73-83
Birch, A.A.
755f2236-4c0c-49b5-9884-de4021acd42d
Neil-Dwyer, G.
19520fec-ecd3-436f-9420-b7bd776751c3
Murrills, A.J.
4874f921-548f-4ac4-9195-34326e37e6cd
19 December 2001
Birch, A.A.
755f2236-4c0c-49b5-9884-de4021acd42d
Neil-Dwyer, G.
19520fec-ecd3-436f-9420-b7bd776751c3
Murrills, A.J.
4874f921-548f-4ac4-9195-34326e37e6cd
Birch, A.A., Neil-Dwyer, G. and Murrills, A.J.
(2001)
The repeatability of cerebral autoregulation assessment using sinusoidal lower body negative pressure.
Physiological Measurement, 23 (1), .
(doi:10.1088/0967-3334/23/1/307).
Abstract
A forced periodic variation in blood pressure produces a similar variation in cerebral blood velocity. The amplitudes and phases of the pressure and velocity waveforms are indicative of the dynamic response of the cerebral autoregulation. The phase of the velocity leads the pressure; the greater the phase difference the faster the autoregulation response. Various techniques have been employed to oscillate arterial blood pressure but measurement reproducibility has been poor. The purpose of this study was to assess the reproducibility of phase measurements when sinusoidal lower body negative pressure is used to vary blood pressure. Five healthy volunteers were assessed at two vacuum levels on each of eight visits. For each measurement a 12 s sinusoidal cycle was maintained for 5 min. The Fourier components of blood pressure and the middle cerebral artery velocity were determined at the oscillation frequency. The phase of velocity consistently led the pressure. The mean phase difference was 42+/-13 degrees for the stronger vacuum and 36+/-42 degrees for the weaker vacuum. The variation given is the within-subjects standard deviation estimated from a one-way analysis of variance. Sinusoidal lower body negative pressure is a useful stimulus for investigating autoregulation; it has advantages over other methods. High vacuums show good reproducibility but are too uncomfortable for patient use.
This record has no associated files available for download.
More information
Published date: 19 December 2001
Keywords:
Adult, Blood Pressure, Blood Pressure Determination, Carbon Dioxide, Cerebrovascular Circulation, Female, Heart Rate, Homeostasis, Humans, Laser-Doppler Flowmetry, Lower Body Negative Pressure, Male, Middle Aged, Reference Values, Reproducibility of Results, Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't
Identifiers
Local EPrints ID: 428312
URI: http://eprints.soton.ac.uk/id/eprint/428312
ISSN: 0967-3334
PURE UUID: 65af08ee-470e-4ec5-a425-f69bc68c2f37
Catalogue record
Date deposited: 20 Feb 2019 17:30
Last modified: 15 Mar 2024 23:57
Export record
Altmetrics
Contributors
Author:
A.A. Birch
Author:
G. Neil-Dwyer
Author:
A.J. Murrills
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics