Effect of magnitude of vertical whole-body vibration on absorbed power for the seated human body
Effect of magnitude of vertical whole-body vibration on absorbed power for the seated human body
The power absorbed by 12 male subjects during exposure to vertical whole-body vibration at six magnitudes of random vibration (0·25, 0·5, 1·0, 1·5, 2·0 and 2·5 ms-2 r.m.s.) has been measured in the laboratory. All subjects showed greatest absorbed power at about 5 Hz, but the frequency of this peak in the absorbed power reduced with increasing vibration magnitude. The total absorbed power increased approximately in proportion to the square of the acceleration magnitude: normalizing the absorbed power to the square of the r.m.s. vibration magnitude removed most of the differences, although the changes in resonance frequency were still evident. The frequency dependence of absorbed power at a constant magnitude of acceleration was approximated by a simple weighting having slopes of ± 6 dB/octave either side of 5 Hz. Comparing the characteristics of this absorbed power weighting to standard frequency weightings showed substantial differences, especially at high frequencies. It is concluded that the differences from currently accepted frequency weightings are so great that the absorbed power is unlikely to yield good general predictions of the discomfort or risks of injury from whole-body vertical vibration.
813-825
Mansfield, N. J.
9fbaeb10-6857-4dc5-aa59-18644d159f0a
Griffin, M. J.
24112494-9774-40cb-91b7-5b4afe3c41b8
27 August 1998
Mansfield, N. J.
9fbaeb10-6857-4dc5-aa59-18644d159f0a
Griffin, M. J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Mansfield, N. J. and Griffin, M. J.
(1998)
Effect of magnitude of vertical whole-body vibration on absorbed power for the seated human body.
Journal of Sound and Vibration, 215 (4), .
(doi:10.1006/jsvi.1998.1596).
Abstract
The power absorbed by 12 male subjects during exposure to vertical whole-body vibration at six magnitudes of random vibration (0·25, 0·5, 1·0, 1·5, 2·0 and 2·5 ms-2 r.m.s.) has been measured in the laboratory. All subjects showed greatest absorbed power at about 5 Hz, but the frequency of this peak in the absorbed power reduced with increasing vibration magnitude. The total absorbed power increased approximately in proportion to the square of the acceleration magnitude: normalizing the absorbed power to the square of the r.m.s. vibration magnitude removed most of the differences, although the changes in resonance frequency were still evident. The frequency dependence of absorbed power at a constant magnitude of acceleration was approximated by a simple weighting having slopes of ± 6 dB/octave either side of 5 Hz. Comparing the characteristics of this absorbed power weighting to standard frequency weightings showed substantial differences, especially at high frequencies. It is concluded that the differences from currently accepted frequency weightings are so great that the absorbed power is unlikely to yield good general predictions of the discomfort or risks of injury from whole-body vertical vibration.
This record has no associated files available for download.
More information
Accepted/In Press date: 16 March 1998
Published date: 27 August 1998
Identifiers
Local EPrints ID: 429458
URI: http://eprints.soton.ac.uk/id/eprint/429458
ISSN: 0022-460X
PURE UUID: 6494a287-a1c5-4a85-aa44-cfefafaa6886
Catalogue record
Date deposited: 27 Mar 2019 17:30
Last modified: 16 Mar 2024 01:05
Export record
Altmetrics
Contributors
Author:
N. J. Mansfield
Author:
M. J. Griffin
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics