Normative vibrotactile thresholds measured at five European test centres

Normative vibrotactile thresholds measured at five European test centres
Normative vibrotactile thresholds measured at five European test centres

Objectives: To compare vibrotactile thresholds between five international test centres, to determine causes of variability, and to provide normative data for use by health professionals. Methods: Vibrotactile thresholds were measured on various fingers in 1,008 subjects at 31.5 Hz (2,531 measurements) and at 125 Hz (2,807 measurements). Three centres used the up-and-down method of limits, rate of change of stimulus 3dB/s, to obtain vibrotactile thresholds. The push force on the surround was 2 N, the probe contact force was 1 N and the probe diameter was 6 mm concentric to a 10-mm diameter hole in the surround. One centre used an up-and-down method of limits with a 5-dB step and a 1.26-mm diameter probe with no surround. Another centre used a stepping algorithm, no surround, and the force on the 6-mm-diameter probe was unspecified. Results: The 31.5-Hz thresholds and 125-Hz thresholds, expressed in dB, were similar between centres using similar methods. There were small (<5 dB) differences in vibrotactile thresholds between male and female subjects, between white-collar and blue-collar workers and between fingers. Both 31.5-Hz and 125-Hz thresholds increased with age; the mean effect of age on 31.5-Hz thresholds was approximately 2 dB over 25 years, while the effect of age on 125 Hz-thresholds was as high as 10 dB over 25 years. Conclusions: Vibrotactile thresholds are influenced by measurement method but can be similar at different centres if similar methods are used. Effects of measurement location and gender are often negligible. Thresholds depend on age, but over the range of ages considered, only the effect on 125-Hz thresholds is sufficient for correction; methods of correcting for age are given. These normative data may be used to assist the diagnosis of peripheral neuropathy involving vibrotactile sensation.

Confounding variables, Measurement methods, Normative data, Vibrotactile thresholds
0340-0131
517-528
Lindsell, Christopher J.
b724b896-71a8-4afa-9d3f-d153d63a963b
Griffin, Michael J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Lindsell, Christopher J.
b724b896-71a8-4afa-9d3f-d153d63a963b
Griffin, Michael J.
24112494-9774-40cb-91b7-5b4afe3c41b8

Lindsell, Christopher J. and Griffin, Michael J. (2003) Normative vibrotactile thresholds measured at five European test centres. International Archives of Occupational and Environmental Health, 76 (7), 517-528.

Record type: Article

Abstract

Objectives: To compare vibrotactile thresholds between five international test centres, to determine causes of variability, and to provide normative data for use by health professionals. Methods: Vibrotactile thresholds were measured on various fingers in 1,008 subjects at 31.5 Hz (2,531 measurements) and at 125 Hz (2,807 measurements). Three centres used the up-and-down method of limits, rate of change of stimulus 3dB/s, to obtain vibrotactile thresholds. The push force on the surround was 2 N, the probe contact force was 1 N and the probe diameter was 6 mm concentric to a 10-mm diameter hole in the surround. One centre used an up-and-down method of limits with a 5-dB step and a 1.26-mm diameter probe with no surround. Another centre used a stepping algorithm, no surround, and the force on the 6-mm-diameter probe was unspecified. Results: The 31.5-Hz thresholds and 125-Hz thresholds, expressed in dB, were similar between centres using similar methods. There were small (<5 dB) differences in vibrotactile thresholds between male and female subjects, between white-collar and blue-collar workers and between fingers. Both 31.5-Hz and 125-Hz thresholds increased with age; the mean effect of age on 31.5-Hz thresholds was approximately 2 dB over 25 years, while the effect of age on 125 Hz-thresholds was as high as 10 dB over 25 years. Conclusions: Vibrotactile thresholds are influenced by measurement method but can be similar at different centres if similar methods are used. Effects of measurement location and gender are often negligible. Thresholds depend on age, but over the range of ages considered, only the effect on 125-Hz thresholds is sufficient for correction; methods of correcting for age are given. These normative data may be used to assist the diagnosis of peripheral neuropathy involving vibrotactile sensation.

This record has no associated files available for download.

More information

Published date: 1 September 2003
Keywords: Confounding variables, Measurement methods, Normative data, Vibrotactile thresholds

Identifiers

Local EPrints ID: 429466
URI: http://eprints.soton.ac.uk/id/eprint/429466
ISSN: 0340-0131
PURE UUID: ad53a808-2350-473e-96fb-e754728f12bb
ORCID for Michael J. Griffin: ORCID iD orcid.org/0000-0003-0743-9502

Catalogue record

Date deposited: 27 Mar 2019 17:30
Last modified: 17 Mar 2024 12:22

Export record

Contributors

Author: Christopher J. Lindsell
Author: Michael J. Griffin ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×