The University of Southampton
University of Southampton Institutional Repository

Corrigendum to “A highly specific Escherichia coli qPCR and its comparison with existing methods for environmental waters” (Water Research (2017) 126 (101–110), (S0043135417306942), (10.1016/j.watres.2017.08.032))

Corrigendum to “A highly specific Escherichia coli qPCR and its comparison with existing methods for environmental waters” (Water Research (2017) 126 (101–110), (S0043135417306942), (10.1016/j.watres.2017.08.032))
Corrigendum to “A highly specific Escherichia coli qPCR and its comparison with existing methods for environmental waters” (Water Research (2017) 126 (101–110), (S0043135417306942), (10.1016/j.watres.2017.08.032))

It has been brought to our attention that there is an error in the Methods, section 2.6 “Real-time PCR”. The article as published states “Each reaction contained 12.5 μl of IQ SYBR Supermix con- taining reaction buffer, dNTPs, Taq polymerase and SYBR Green II DNA binding dye (Biorad), 9.5 μl of RT-PCR grade water (Agilent), 1 ml of each primer (final concentration 5 mM) and 1 ml of template DNA at 100 ng/μl; the final volume was 25 μl.”. However this should be “Each reaction contained 12.5 μl of IQ SYBR Supermix con- taining reaction buffer, dNTPs, Taq polymerase and SYBR Green II DNA binding dye (Biorad), 9.5 μl of RT-PCR grade water (Agilent), 1 μl of each primer (final concentration 0.4 μM) and 1 μl of template DNA at 100 ng/μl; the final volume was 25 μl.”

0043-1354
652
Walker, David I.
f80437ee-76da-496e-bf2a-ac1ac170159f
McQuillan, Jonathan
697cdf72-f353-4779-b64a-45494f29772f
Taiwo, Michael
3ac7811b-4d5d-487b-9a49-4453595c2e61
Parks, Rachel
342f6345-2cbb-4480-921f-97e5d8a6265d
Stenton, Craig A.
e7880000-c3b9-4c7d-8e67-26483e5386f9
Morgan, H.
de00d59f-a5a2-48c4-a99a-1d5dd7854174
Mowlem, Matthew C.
6f633ca2-298f-48ee-a025-ce52dd62124f
Lees, David N.
276df848-c299-43bb-a340-43ebd8604541
Walker, David I.
f80437ee-76da-496e-bf2a-ac1ac170159f
McQuillan, Jonathan
697cdf72-f353-4779-b64a-45494f29772f
Taiwo, Michael
3ac7811b-4d5d-487b-9a49-4453595c2e61
Parks, Rachel
342f6345-2cbb-4480-921f-97e5d8a6265d
Stenton, Craig A.
e7880000-c3b9-4c7d-8e67-26483e5386f9
Morgan, H.
de00d59f-a5a2-48c4-a99a-1d5dd7854174
Mowlem, Matthew C.
6f633ca2-298f-48ee-a025-ce52dd62124f
Lees, David N.
276df848-c299-43bb-a340-43ebd8604541

Walker, David I., McQuillan, Jonathan, Taiwo, Michael, Parks, Rachel, Stenton, Craig A., Morgan, H., Mowlem, Matthew C. and Lees, David N. (2019) Corrigendum to “A highly specific Escherichia coli qPCR and its comparison with existing methods for environmental waters” (Water Research (2017) 126 (101–110), (S0043135417306942), (10.1016/j.watres.2017.08.032)). Water Research, 161, 652. (doi:10.1016/j.watres.2019.06.070).

Record type: Letter

Abstract

It has been brought to our attention that there is an error in the Methods, section 2.6 “Real-time PCR”. The article as published states “Each reaction contained 12.5 μl of IQ SYBR Supermix con- taining reaction buffer, dNTPs, Taq polymerase and SYBR Green II DNA binding dye (Biorad), 9.5 μl of RT-PCR grade water (Agilent), 1 ml of each primer (final concentration 5 mM) and 1 ml of template DNA at 100 ng/μl; the final volume was 25 μl.”. However this should be “Each reaction contained 12.5 μl of IQ SYBR Supermix con- taining reaction buffer, dNTPs, Taq polymerase and SYBR Green II DNA binding dye (Biorad), 9.5 μl of RT-PCR grade water (Agilent), 1 μl of each primer (final concentration 0.4 μM) and 1 μl of template DNA at 100 ng/μl; the final volume was 25 μl.”

This record has no associated files available for download.

More information

e-pub ahead of print date: 4 July 2019
Published date: 15 September 2019

Identifiers

Local EPrints ID: 432380
URI: http://eprints.soton.ac.uk/id/eprint/432380
ISSN: 0043-1354
PURE UUID: 096c965b-5298-45b6-b51e-c0890d3a9f3d
ORCID for H. Morgan: ORCID iD orcid.org/0000-0003-4850-5676
ORCID for Matthew C. Mowlem: ORCID iD orcid.org/0000-0001-7613-6121

Catalogue record

Date deposited: 12 Jul 2019 16:30
Last modified: 16 Mar 2024 03:36

Export record

Altmetrics

Contributors

Author: David I. Walker
Author: Jonathan McQuillan
Author: Michael Taiwo
Author: Rachel Parks
Author: Craig A. Stenton
Author: H. Morgan ORCID iD
Author: Matthew C. Mowlem ORCID iD
Author: David N. Lees

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×