Evaluation of the volumetric erosion of spherical electrical contacts using the defect removal method
Evaluation of the volumetric erosion of spherical electrical contacts using the defect removal method
Volumetric erosion is regarded as a significant index for studying the erosion process of electrical switching contacts. Three-dimensional (3-D) surface measurement techniques provide an approach to investigate the geometric characteristics and volumetric erosion of electrical contacts. This paper presents a concrete data-processing procedure for evaluating volumetric erosion of spherical electrical contacts from 3-D surface measurement data using the defect removal method (DRM). The DRM outlined by McBride is an algorithm for evaluating the underlying form (prior to erosion) parameters of the surfaces with localized erosion and allowing the erosion characteristics themselves to be isolated. In this paper, a number of spherical electrical contacts that had undergone various electrical operations were measured using a 3-D surface profiler, the underlying form parameters of the eroded contacts were evaluated using the DRM, and then the volumetric erosions were isolated and calculated. The analysis of the correlations between the volumetric erosion and the number of switching cycles of electrical operation that the contacts had undergone showed a more accurate and reliable volumetric erosion evaluation using the DRM than that without using the DRM.
711-717
Zhang, D.
1c04f0f4-c07c-4671-8fd0-fa07a685fea2
Hill, M.
0cda65c8-a70f-476f-b126-d2c4460a253e
McBride, J.W.
d9429c29-9361-4747-9ba3-376297cb8770
2006
Zhang, D.
1c04f0f4-c07c-4671-8fd0-fa07a685fea2
Hill, M.
0cda65c8-a70f-476f-b126-d2c4460a253e
McBride, J.W.
d9429c29-9361-4747-9ba3-376297cb8770
Zhang, D., Hill, M. and McBride, J.W.
(2006)
Evaluation of the volumetric erosion of spherical electrical contacts using the defect removal method.
IEEE Transactions on Components and Packaging Technologies, 29 (4), .
(doi:10.1109/TCAPT.2006.880523).
Abstract
Volumetric erosion is regarded as a significant index for studying the erosion process of electrical switching contacts. Three-dimensional (3-D) surface measurement techniques provide an approach to investigate the geometric characteristics and volumetric erosion of electrical contacts. This paper presents a concrete data-processing procedure for evaluating volumetric erosion of spherical electrical contacts from 3-D surface measurement data using the defect removal method (DRM). The DRM outlined by McBride is an algorithm for evaluating the underlying form (prior to erosion) parameters of the surfaces with localized erosion and allowing the erosion characteristics themselves to be isolated. In this paper, a number of spherical electrical contacts that had undergone various electrical operations were measured using a 3-D surface profiler, the underlying form parameters of the eroded contacts were evaluated using the DRM, and then the volumetric erosions were isolated and calculated. The analysis of the correlations between the volumetric erosion and the number of switching cycles of electrical operation that the contacts had undergone showed a more accurate and reliable volumetric erosion evaluation using the DRM than that without using the DRM.
Text
43340.pdf
- Version of Record
More information
Published date: 2006
Identifiers
Local EPrints ID: 43340
URI: http://eprints.soton.ac.uk/id/eprint/43340
ISSN: 1521-3331
PURE UUID: 71dcffcd-c73a-4a86-8ef3-c8df007d6241
Catalogue record
Date deposited: 23 Jan 2007
Last modified: 16 Mar 2024 02:41
Export record
Altmetrics
Contributors
Author:
D. Zhang
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics