A comparison of DEF X-ray film and a photodiode array (reticon) as detectors for an x-ray crystal spectrometer
A comparison of DEF X-ray film and a photodiode array (reticon) as detectors for an x-ray crystal spectrometer
A crystal spectrometer with a photodiode array (PDA) detector was tested for a range of x-ray energies between 1 and 2 keV. A laser-produced plasma has been used as an x-ray source and was generated by the high-power (Vulcan) glass laser system at the SERC Rutherford Appleton Laboratory, UK. The performance of the array was directly compared with the response of Kodak DEF x-ray film. In order to compare quantitatively the performances of the PDA and the film, detective quantum efficiency (DQE) considerations are presented for both devices. It is demonstrated that the PDA has a useful dynamic range which is approximately seven times greater than that of film, a peak DQE of approximately six times that of film, and a greatly superior low-signal performance. The operational characteristics of the PDA are discussed.
Journal of X-ray Science and Technology (1989) Vol.1(2) pp.
doi: 10.1016/0895-3996(89)90039-6
162-170
Goodman, D.A.
cb14f0b3-48a4-4eb0-ab1a-2d5478cbcf3a
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Shiwai, B.
ac57f708-3440-41e8-bfc4-5f615c2f8bb0
Allinson, N.M.
1f198115-20bd-4ed3-a70d-bb5d9368eb57
Magorrian, B.
d3fac681-5f64-43c0-bfc9-28236c7b948f
Grande, M.
0b9b50ba-5db8-4f62-84c7-d363d0910264
Ridgeley, A.
0ac92380-8e45-4fe4-b4a0-8d06c7009de2
October 1989
Goodman, D.A.
cb14f0b3-48a4-4eb0-ab1a-2d5478cbcf3a
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Shiwai, B.
ac57f708-3440-41e8-bfc4-5f615c2f8bb0
Allinson, N.M.
1f198115-20bd-4ed3-a70d-bb5d9368eb57
Magorrian, B.
d3fac681-5f64-43c0-bfc9-28236c7b948f
Grande, M.
0b9b50ba-5db8-4f62-84c7-d363d0910264
Ridgeley, A.
0ac92380-8e45-4fe4-b4a0-8d06c7009de2
Goodman, D.A., Eason, R.W., Shiwai, B., Allinson, N.M., Magorrian, B., Grande, M. and Ridgeley, A.
(1989)
A comparison of DEF X-ray film and a photodiode array (reticon) as detectors for an x-ray crystal spectrometer.
Journal of X-Ray Science and Technology, 1 (2), .
(doi:10.1016/0895-3996(89)90039-6).
Abstract
A crystal spectrometer with a photodiode array (PDA) detector was tested for a range of x-ray energies between 1 and 2 keV. A laser-produced plasma has been used as an x-ray source and was generated by the high-power (Vulcan) glass laser system at the SERC Rutherford Appleton Laboratory, UK. The performance of the array was directly compared with the response of Kodak DEF x-ray film. In order to compare quantitatively the performances of the PDA and the film, detective quantum efficiency (DQE) considerations are presented for both devices. It is demonstrated that the PDA has a useful dynamic range which is approximately seven times greater than that of film, a peak DQE of approximately six times that of film, and a greatly superior low-signal performance. The operational characteristics of the PDA are discussed.
Journal of X-ray Science and Technology (1989) Vol.1(2) pp.
doi: 10.1016/0895-3996(89)90039-6
This record has no associated files available for download.
More information
Published date: October 1989
Identifiers
Local EPrints ID: 435275
URI: http://eprints.soton.ac.uk/id/eprint/435275
ISSN: 0895-3996
PURE UUID: 3da2c44b-68b7-4bed-a312-f0a95673060d
Catalogue record
Date deposited: 29 Oct 2019 17:30
Last modified: 17 Mar 2024 02:35
Export record
Altmetrics
Contributors
Author:
D.A. Goodman
Author:
R.W. Eason
Author:
B. Shiwai
Author:
N.M. Allinson
Author:
B. Magorrian
Author:
M. Grande
Author:
A. Ridgeley
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics