A crystal spectrometer with a photodiode array (PDA) detector was tested for a range of x-ray energies between 1 and 2 keV. A laser-produced plasma has been used as an x-ray source and was generated by the high-power (Vulcan) glass laser system at the SERC Rutherford Appleton Laboratory, UK. The performance of the array was directly compared with the response of Kodak DEF x-ray film. In order to compare quantitatively the performances of the PDA and the film, detective quantum efficiency (DQE) considerations are presented for both devices. It is demonstrated that the PDA has a useful dynamic range which is approximately seven times greater than that of film, a peak DQE of approximately six times that of film, and a greatly superior low-signal performance. The operational characteristics of the PDA are discussed.


Journal of X-ray Science and Technology (1989) Vol.1(2) pp.

doi: 10.1016/0895-3996(89)90039-6
0895-3996
162-170
Goodman, D.A.
cb14f0b3-48a4-4eb0-ab1a-2d5478cbcf3a
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Shiwai, B.
ac57f708-3440-41e8-bfc4-5f615c2f8bb0
Allinson, N.M.
1f198115-20bd-4ed3-a70d-bb5d9368eb57
Magorrian, B.
d3fac681-5f64-43c0-bfc9-28236c7b948f
Grande, M.
0b9b50ba-5db8-4f62-84c7-d363d0910264
Ridgeley, A.
0ac92380-8e45-4fe4-b4a0-8d06c7009de2
Goodman, D.A.
cb14f0b3-48a4-4eb0-ab1a-2d5478cbcf3a
Eason, R.W.
e38684c3-d18c-41b9-a4aa-def67283b020
Shiwai, B.
ac57f708-3440-41e8-bfc4-5f615c2f8bb0
Allinson, N.M.
1f198115-20bd-4ed3-a70d-bb5d9368eb57
Magorrian, B.
d3fac681-5f64-43c0-bfc9-28236c7b948f
Grande, M.
0b9b50ba-5db8-4f62-84c7-d363d0910264
Ridgeley, A.
0ac92380-8e45-4fe4-b4a0-8d06c7009de2

Goodman, D.A., Eason, R.W., Shiwai, B., Allinson, N.M., Magorrian, B., Grande, M. and Ridgeley, A. (1989) A comparison of DEF X-ray film and a photodiode array (reticon) as detectors for an x-ray crystal spectrometer. Journal of X-Ray Science and Technology, 1 (2), 162-170. (doi:10.1016/0895-3996(89)90039-6).

Record type: Article

Abstract

A crystal spectrometer with a photodiode array (PDA) detector was tested for a range of x-ray energies between 1 and 2 keV. A laser-produced plasma has been used as an x-ray source and was generated by the high-power (Vulcan) glass laser system at the SERC Rutherford Appleton Laboratory, UK. The performance of the array was directly compared with the response of Kodak DEF x-ray film. In order to compare quantitatively the performances of the PDA and the film, detective quantum efficiency (DQE) considerations are presented for both devices. It is demonstrated that the PDA has a useful dynamic range which is approximately seven times greater than that of film, a peak DQE of approximately six times that of film, and a greatly superior low-signal performance. The operational characteristics of the PDA are discussed.


Journal of X-ray Science and Technology (1989) Vol.1(2) pp.

doi: 10.1016/0895-3996(89)90039-6

This record has no associated files available for download.

More information

Published date: October 1989

Identifiers

Local EPrints ID: 435275
URI: http://eprints.soton.ac.uk/id/eprint/435275
ISSN: 0895-3996
PURE UUID: 3da2c44b-68b7-4bed-a312-f0a95673060d
ORCID for R.W. Eason: ORCID iD orcid.org/0000-0001-9704-2204

Catalogue record

Date deposited: 29 Oct 2019 17:30
Last modified: 17 Mar 2024 02:35

Export record

Altmetrics

Contributors

Author: D.A. Goodman
Author: R.W. Eason ORCID iD
Author: B. Shiwai
Author: N.M. Allinson
Author: B. Magorrian
Author: M. Grande
Author: A. Ridgeley

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×