Using listening tests to demonstrate the subjective performance of a superdirective TV loudspeaker array

Using listening tests to demonstrate the subjective performance of a superdirective TV loudspeaker array
Using listening tests to demonstrate the subjective performance of a superdirective TV loudspeaker array

Difficulties in understanding speech content in TV programmes are a common problem for listeners with age-related hearing loss. To address this problem, a superdirective TV loudspeaker array has been designed, which boosts the higher frequencies of the TV audio at selected positions in the room. The effectiveness of the system was assessed by objective measurements and subjective evaluation in the form of listening tests. The subjective performance of the array has been investigated in terms of the intelligibility of speech at the selected position, by applying a hearing loss simulator on normal hearing subjects, and the perceived quality for a normal hearing person outside of the selected position. For this purpose, two separate listening tests were performed, focusing on each of these two aspects. To evaluate the intelligibility of speech, short sentences were played back under different conditions to a panel of 33 subjects. Another 17 subjects participated in the evaluation of quality. At equal background noise level, it was found that for people listening via the hearing loss simulator, significantly more words were recognised using the array than without the array, showing that the intelligibility was improved. The speechto-noise-ratio, for which 50% of the words are recognised, was improved for these listeners from 0.5dB with the array switched off to-4.1dB with the array at 0dB gain for the array with respect to an ordinary TV speaker. The quality evaluation, based on ITU-R BS.1534 (MUSHRA), showed that at 0dB gain, the quality outside of the beam was still perceived as 'good' compared to the case where the array was switched off. However, increasing the gain to +3dB, reduced the quality which was then perceived on average as 'fair'.

European Acoustics Association, EAA
Marker, Arthur
0be3e6a2-817b-425f-8c2c-86cf6c7cc45a
Elliott, Stephen J.
721dc55c-8c3e-4895-b9c4-82f62abd3567
Simón Gálvez, Marcos F.
777da25f-86fc-4a22-8ff1-ac2cbbfe27ae
Bleeck, Stefan
c888ccba-e64c-47bf-b8fa-a687e87ec16c
Borkowski, Bartlomiej
Marker, Arthur
0be3e6a2-817b-425f-8c2c-86cf6c7cc45a
Elliott, Stephen J.
721dc55c-8c3e-4895-b9c4-82f62abd3567
Simón Gálvez, Marcos F.
777da25f-86fc-4a22-8ff1-ac2cbbfe27ae
Bleeck, Stefan
c888ccba-e64c-47bf-b8fa-a687e87ec16c
Borkowski, Bartlomiej

Marker, Arthur, Elliott, Stephen J., Simón Gálvez, Marcos F. and Bleeck, Stefan (2014) Using listening tests to demonstrate the subjective performance of a superdirective TV loudspeaker array. Borkowski, Bartlomiej (ed.) In Forum Acusticum, FA 2014. vol. 2014-January, European Acoustics Association, EAA..

Record type: Conference or Workshop Item (Paper)

Abstract

Difficulties in understanding speech content in TV programmes are a common problem for listeners with age-related hearing loss. To address this problem, a superdirective TV loudspeaker array has been designed, which boosts the higher frequencies of the TV audio at selected positions in the room. The effectiveness of the system was assessed by objective measurements and subjective evaluation in the form of listening tests. The subjective performance of the array has been investigated in terms of the intelligibility of speech at the selected position, by applying a hearing loss simulator on normal hearing subjects, and the perceived quality for a normal hearing person outside of the selected position. For this purpose, two separate listening tests were performed, focusing on each of these two aspects. To evaluate the intelligibility of speech, short sentences were played back under different conditions to a panel of 33 subjects. Another 17 subjects participated in the evaluation of quality. At equal background noise level, it was found that for people listening via the hearing loss simulator, significantly more words were recognised using the array than without the array, showing that the intelligibility was improved. The speechto-noise-ratio, for which 50% of the words are recognised, was improved for these listeners from 0.5dB with the array switched off to-4.1dB with the array at 0dB gain for the array with respect to an ordinary TV speaker. The quality evaluation, based on ITU-R BS.1534 (MUSHRA), showed that at 0dB gain, the quality outside of the beam was still perceived as 'good' compared to the case where the array was switched off. However, increasing the gain to +3dB, reduced the quality which was then perceived on average as 'fair'.

This record has no associated files available for download.

More information

Published date: 1 January 2014
Venue - Dates: 7th Forum Acusticum, FA 2014, , Krakow, Poland, 2014-09-07 - 2014-09-12

Identifiers

Local EPrints ID: 436062
URI: http://eprints.soton.ac.uk/id/eprint/436062
PURE UUID: a2b1b619-e845-4ff3-a0a5-2f064bdff794
ORCID for Stefan Bleeck: ORCID iD orcid.org/0000-0003-4378-3394

Catalogue record

Date deposited: 27 Nov 2019 17:30
Last modified: 31 Jul 2024 01:40

Export record

Contributors

Author: Arthur Marker
Author: Stefan Bleeck ORCID iD
Editor: Bartlomiej Borkowski

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×