The University of Southampton
University of Southampton Institutional Repository

Comparison between object and image plane cross-correlation for stereoscopic PIV in the presence of pixel locking

Comparison between object and image plane cross-correlation for stereoscopic PIV in the presence of pixel locking
Comparison between object and image plane cross-correlation for stereoscopic PIV in the presence of pixel locking

Abstract: Pixel locking in stereoscopic particle image velocimetry (SPIV) is often overlooked, albeit the existence of studies demonstrating an influence on turbulent statistics. Such a bias error occurs when the seeding particles have an image diameter in the range of 1–2 pixels. Together with the advent of superior cameras and more powerful lasers, new image-processing techniques enable large field of views to be examined. Under such circumstances, defocusing is not an option and due to the small nature of the particle image diameter, pixel locking is inherent in the data. This study analyses the contrast between object plane-based and image plane-based approach for cross-correlation in the presence of pixel locking in SPIV. By combining experimental data and synthetic images, the sensitivity of pixel locking on single-point statistics is quantified and a protocol is proposed to tackle such an increasingly prevalent condition. A consequence of pixel locking is the occurrence of Moiré fringes, whose intensity is observed to be enhanced in the presence of particles with an image diameter less than 2 pixels. Such high frequency artifacts are not only receptive to the fill factor of the sensor but also depend on the residual error of the interpolation from image plane to the object plane. This study discusses the origins of Moiré fringes in SPIV and provides a method to mitigate these based on the type of cross-correlation used. Graphic abstract: Variation of the difference in RMS between the true value and the derived value from diverse adopted methodologies as the particle image diameter, d τ increases. (OP: Object plane cross-correlation, IP: Image plane cross-correlation, IP HE: Image plane cross-correlation post histogram equalisation) [Figure not available: see fulltext.].

0723-4864
Jankee, Girish, K.
ae50bc76-d591-4ec8-9a60-421b2336f5a7
Ganapathisubramani, Bharathram
5e69099f-2f39-4fdd-8a85-3ac906827052
Jankee, Girish, K.
ae50bc76-d591-4ec8-9a60-421b2336f5a7
Ganapathisubramani, Bharathram
5e69099f-2f39-4fdd-8a85-3ac906827052

Jankee, Girish, K. and Ganapathisubramani, Bharathram (2020) Comparison between object and image plane cross-correlation for stereoscopic PIV in the presence of pixel locking. Experiments in Fluids, 61 (3), [89]. (doi:10.1007/s00348-020-2916-x).

Record type: Article

Abstract

Abstract: Pixel locking in stereoscopic particle image velocimetry (SPIV) is often overlooked, albeit the existence of studies demonstrating an influence on turbulent statistics. Such a bias error occurs when the seeding particles have an image diameter in the range of 1–2 pixels. Together with the advent of superior cameras and more powerful lasers, new image-processing techniques enable large field of views to be examined. Under such circumstances, defocusing is not an option and due to the small nature of the particle image diameter, pixel locking is inherent in the data. This study analyses the contrast between object plane-based and image plane-based approach for cross-correlation in the presence of pixel locking in SPIV. By combining experimental data and synthetic images, the sensitivity of pixel locking on single-point statistics is quantified and a protocol is proposed to tackle such an increasingly prevalent condition. A consequence of pixel locking is the occurrence of Moiré fringes, whose intensity is observed to be enhanced in the presence of particles with an image diameter less than 2 pixels. Such high frequency artifacts are not only receptive to the fill factor of the sensor but also depend on the residual error of the interpolation from image plane to the object plane. This study discusses the origins of Moiré fringes in SPIV and provides a method to mitigate these based on the type of cross-correlation used. Graphic abstract: Variation of the difference in RMS between the true value and the derived value from diverse adopted methodologies as the particle image diameter, d τ increases. (OP: Object plane cross-correlation, IP: Image plane cross-correlation, IP HE: Image plane cross-correlation post histogram equalisation) [Figure not available: see fulltext.].

Text
Article - Accepted Manuscript
Download (1MB)
Text
Jankee-Ganapathisubramani2020_Article_ComparisonBetweenObjectAndImag - Version of Record
Available under License Creative Commons Attribution.
Download (1MB)

More information

Accepted/In Press date: 11 February 2020
e-pub ahead of print date: 3 March 2020
Published date: 3 March 2020
Additional Information: Funding Information: This project was funded by the Engineering and Physical Sciences Research Council (EPSRC Grant No. EP/L006383/1). The authors are grateful to Mr Manuel A. Ferreira for his help in acquiring the experimental data in Sect. 5 and Dr Eduardo Rodriguez-Lopez for testing and debugging the in-house SPIV reconstruction script and for insightful conversations about Moiré fringes. Publisher Copyright: © 2020, The Author(s).

Identifiers

Local EPrints ID: 438384
URI: http://eprints.soton.ac.uk/id/eprint/438384
ISSN: 0723-4864
PURE UUID: d9bd78dc-3e50-4013-8eae-132f90881739
ORCID for Girish, K. Jankee: ORCID iD orcid.org/0000-0002-9178-1070
ORCID for Bharathram Ganapathisubramani: ORCID iD orcid.org/0000-0001-9817-0486

Catalogue record

Date deposited: 09 Mar 2020 17:30
Last modified: 06 Jun 2024 04:18

Export record

Altmetrics

Contributors

Author: Girish, K. Jankee ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×