Comparison of SPECT aerosol deposition data with twenty-four-hour clearance measurements

Comparison of SPECT aerosol deposition data with twenty-four-hour clearance measurements
Comparison of SPECT aerosol deposition data with twenty-four-hour clearance measurements
Three-dimensional (3D) radionuclide imaging provides detailed information on the distribution of inhaled aerosol material within the body. Analysis of the data can provide estimates of the deposition per airway generation. Information on regional distribution of deposited aerosol can also be obtained from 24-hour clearance measurements. In this study, a nebulizer was used to deliver a radiolabeled aerosol to nine human subjects. Single photon emission computed tomography (SPECT) has been used to assess the distribution of aerosol deposition per airway generation. The deposition pattern was also estimated using measurements of the aerosol remaining in the lung 24 h after inhalation. The error in the SPECT value was assessed by simulation and that in the 24-h clearance value by repeat analysis. The mean fraction of lung deposition in the conducting airway (CADF) from SPECT was 0.21. The corresponding 24-h clearance value was 0.23. These values were not significantly different. There was a weak but non-significant correlation between the SPECT and 24-h measurements (r = 0.49). The standard error of the difference was 0.11. The corresponding errors on the SPECT and 24-h clearance measurements were 0.04 and 0.05, respectively. There was no systematic difference between the values of conducting airways deposition obtained from 24-h measurements and SPECT. However, there were random differences on individual subjects, which were larger than the estimated measurement errors.
261-267
Fleming, J.S.
bf089a52-bc49-402a-9129-0dfecf452936
Quint, M.
1ab9aafa-68e9-43e7-83b7-0251cd3e679a
Bolt, L.
6030050a-498b-4e67-b65e-5575828e1c22
Martonen, T.B.
dd064c81-9ebc-40bb-97df-be689787fc8e
Conway, J.H.
bbe9a2e4-fb85-4d4a-a38c-0c1832c32d06
Fleming, J.S.
bf089a52-bc49-402a-9129-0dfecf452936
Quint, M.
1ab9aafa-68e9-43e7-83b7-0251cd3e679a
Bolt, L.
6030050a-498b-4e67-b65e-5575828e1c22
Martonen, T.B.
dd064c81-9ebc-40bb-97df-be689787fc8e
Conway, J.H.
bbe9a2e4-fb85-4d4a-a38c-0c1832c32d06

Fleming, J.S., Quint, M., Bolt, L., Martonen, T.B. and Conway, J.H. (2006) Comparison of SPECT aerosol deposition data with twenty-four-hour clearance measurements. Journal of Aerosol Medicine, 19 (3), 261-267.

Record type: Article

Abstract

Three-dimensional (3D) radionuclide imaging provides detailed information on the distribution of inhaled aerosol material within the body. Analysis of the data can provide estimates of the deposition per airway generation. Information on regional distribution of deposited aerosol can also be obtained from 24-hour clearance measurements. In this study, a nebulizer was used to deliver a radiolabeled aerosol to nine human subjects. Single photon emission computed tomography (SPECT) has been used to assess the distribution of aerosol deposition per airway generation. The deposition pattern was also estimated using measurements of the aerosol remaining in the lung 24 h after inhalation. The error in the SPECT value was assessed by simulation and that in the 24-h clearance value by repeat analysis. The mean fraction of lung deposition in the conducting airway (CADF) from SPECT was 0.21. The corresponding 24-h clearance value was 0.23. These values were not significantly different. There was a weak but non-significant correlation between the SPECT and 24-h measurements (r = 0.49). The standard error of the difference was 0.11. The corresponding errors on the SPECT and 24-h clearance measurements were 0.04 and 0.05, respectively. There was no systematic difference between the values of conducting airways deposition obtained from 24-h measurements and SPECT. However, there were random differences on individual subjects, which were larger than the estimated measurement errors.

This record has no associated files available for download.

More information

Published date: 2006

Identifiers

Local EPrints ID: 44141
URI: http://eprints.soton.ac.uk/id/eprint/44141
PURE UUID: 8e564b38-0cff-4009-b9b4-aaeab217d84c
ORCID for J.H. Conway: ORCID iD orcid.org/0000-0001-6464-1526

Catalogue record

Date deposited: 16 Feb 2007
Last modified: 08 Jan 2022 19:00

Export record

Contributors

Author: J.S. Fleming
Author: M. Quint
Author: L. Bolt
Author: T.B. Martonen
Author: J.H. Conway ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×