READ ME File For 'Dataset for article "UV Induced Resistive Switching in Hybrid Polymer Metal Oxide Memristors"' Dataset DOI: <<< NOT YET ISSUED >>> Licence: CC BY Paper title: UV Induced Resistive Switching in Hybrid Polymer Metal Oxide Memristors Authors: Spyros Stathopoulos, Ioulia Tzouvadaki and Themis Prodromakis Corr. author: Prof Themis Prodromakis (t.prodromakis@soton.ac.uk) ORCID: 0000-0002-6267-6909 Institution: University of Southampton Department: Zepler Institute for Photonics and Nanoelectronics Group: Centre for Electronics Frontiers Address: Highfield Campus, Southampton, SO17 1BJ, UK Period of data collection: Oct 2019 to Nov 2019 Related projects: EP/R024642/1; European Commission Horizon 2020 NeMESIS (Grant: 796366) Manuscript accepted: 06 November 2020 Journal: Scientific Reports Publication DOI: <<< NOT YET ISSUED >>> ############################################################################## Instructions on reading the provided data ========================================= The data for each figure is contained within its respective folder. All figures are accompanied by their corresponding gnuplot script used to generate it. Gnuplot is open source software [1]. The scripts can be used either by double-clicking on them (provided gnuplot is installed) or loaded directly through the command line (quotes are mandatory). > load 'FILENAME.gpl' [1] http://www.gnuplot.info Unless otherwise mentioned in this document all units are in SI standard units. All data are in tsv format (tab separated ASCII) Figure 1 -------- Conceptual information; no actual data used Figure 2 - Comparative responses under different regimes -------------------------------------------------------- Response of the device for different regimes: pristine device without functionalisation; functionalised device illuminated at 1000 nm; functionalised device illuminated at 300 nm. The 1000 nm files contain measurement data (every 1 sec). The 300nm_325nm_350nm file contains measurement data (every 1 sec) for illumination at 350 nm (column 1), 325 nm (column 2), 300 nm (column 3). Only column 3 is used for the production of this figure Figure 3 - Wavelength dependent response ---------------------------------------- Response of the device in UV for three different wavelengths. This figure reuses data file 'MIM_300nm_325nm_350nm_polymer_retention.tsv' also used for figure 2. All 3 columns of the file are plotted. Figure 4 - Pre and post illumination comparison ----------------------------------------------- Comparison of the resistive state of the device before (left side) and at the end of the illumination indicating the difference in resistive values.