The University of Southampton
University of Southampton Institutional Repository

The electron transfer kinetics of adsorbed species derived by sampled current voltammetry

The electron transfer kinetics of adsorbed species derived by sampled current voltammetry
The electron transfer kinetics of adsorbed species derived by sampled current voltammetry

In sampled current voltammetry, a sampled current voltammogram (SCV) is constructed by performing a number of potential steps and plotting the currents taken at a specific sampling time against the corresponding step potentials. For diffusion-controlled processes, the technique produces sigmoidal current-potential curves that are easily analysed to obtain kinetic information. Here, we extend this approach to study the electron transfer kinetics of adsorbed species (O ads+ne ⇌k bk fR ads) and show that the SCVs have a characteristic peak whose shape, potential and current depend on the sampling time. We also discuss the results in terms of chronocoulograms and show that the sampled charge voltacoulograms (SQVs) are also affected by kinetics. Analysis of the SCVs and SQVs is particularly useful to unravel the dependence of the electrode response on potential and time. We investigate different data treatments and show that a logarithmic SCV, a plot of ln(j) against E, is highly sensitive to the electron transfer rate constant and to the sampling time. The time dependence of the current yields Γ O 0 (initial surface coverage) and E 0, while the potential dependence of the current extrapolated to very short sampling times yields α and k s. This extrapolation bypasses the double layer charging distortion, provided the sampling times are selected where the current transients are free from capacitive distortion. From the analysis of the SCVs, we propose a simple protocol to derive Γ O 0, E 0, α and k s, from only two current transients, the only constraint being that one of the chronoamperograms must be recorded with a large overpotential, circa ±120 mV. We also propose a simpler alternative involving non-linear regression of the current transients to a single expression. The chronoamperometric approach offers advantages compared to the voltammetric methodology proposed by Laviron. 1) Capacitive distortions only affect the current transients at short times but affect the whole potential window in voltammetry. 2) The current transients can be extrapolated to very short sampling times where the backward reaction has no influence. 3) The extrapolation to very short sampling times bypasses the double layer distortion. 4) Whereas a chronoamperogram holds a wide range of timescales, the voltammetric approach requires a wide range of scan rates to distinguish the kinetic regimes. 5) The voltammetric method only yields the values of k s and α, while the chronoamperometric method also yields Γ O 0 and E 0. 6) Since electrochemical workstations allow shorter time scales by chronoamperometry than voltammetry, the method can assess faster electron transfer kinetics than conventional cyclic voltammetry.

SCV, SQV, Sampled current voltammetry, electron transfer kinetics, sampled charge voltacoulommetry
1572-6657
Rodriguez Martinez, Oliver
db4ea889-5239-4b2b-a744-7c953461b13f
Denuault, Guy
5c76e69f-e04e-4be5-83c5-e729887ffd4e
Rodriguez Martinez, Oliver
db4ea889-5239-4b2b-a744-7c953461b13f
Denuault, Guy
5c76e69f-e04e-4be5-83c5-e729887ffd4e

Rodriguez Martinez, Oliver and Denuault, Guy (2021) The electron transfer kinetics of adsorbed species derived by sampled current voltammetry. Journal of Electroanalytical Chemistry, 882, [115021]. (doi:10.1016/j.jelechem.2021.115021).

Record type: Article

Abstract

In sampled current voltammetry, a sampled current voltammogram (SCV) is constructed by performing a number of potential steps and plotting the currents taken at a specific sampling time against the corresponding step potentials. For diffusion-controlled processes, the technique produces sigmoidal current-potential curves that are easily analysed to obtain kinetic information. Here, we extend this approach to study the electron transfer kinetics of adsorbed species (O ads+ne ⇌k bk fR ads) and show that the SCVs have a characteristic peak whose shape, potential and current depend on the sampling time. We also discuss the results in terms of chronocoulograms and show that the sampled charge voltacoulograms (SQVs) are also affected by kinetics. Analysis of the SCVs and SQVs is particularly useful to unravel the dependence of the electrode response on potential and time. We investigate different data treatments and show that a logarithmic SCV, a plot of ln(j) against E, is highly sensitive to the electron transfer rate constant and to the sampling time. The time dependence of the current yields Γ O 0 (initial surface coverage) and E 0, while the potential dependence of the current extrapolated to very short sampling times yields α and k s. This extrapolation bypasses the double layer charging distortion, provided the sampling times are selected where the current transients are free from capacitive distortion. From the analysis of the SCVs, we propose a simple protocol to derive Γ O 0, E 0, α and k s, from only two current transients, the only constraint being that one of the chronoamperograms must be recorded with a large overpotential, circa ±120 mV. We also propose a simpler alternative involving non-linear regression of the current transients to a single expression. The chronoamperometric approach offers advantages compared to the voltammetric methodology proposed by Laviron. 1) Capacitive distortions only affect the current transients at short times but affect the whole potential window in voltammetry. 2) The current transients can be extrapolated to very short sampling times where the backward reaction has no influence. 3) The extrapolation to very short sampling times bypasses the double layer distortion. 4) Whereas a chronoamperogram holds a wide range of timescales, the voltammetric approach requires a wide range of scan rates to distinguish the kinetic regimes. 5) The voltammetric method only yields the values of k s and α, while the chronoamperometric method also yields Γ O 0 and E 0. 6) Since electrochemical workstations allow shorter time scales by chronoamperometry than voltammetry, the method can assess faster electron transfer kinetics than conventional cyclic voltammetry.

Text
20210112_manuscript with two column format_v2 - Accepted Manuscript
Download (762kB)

More information

Accepted/In Press date: 14 January 2021
e-pub ahead of print date: 19 January 2021
Published date: 1 February 2021
Additional Information: Funding Information: O.R. thanks CONACYT, Mexico, (grant CONACYT-I2T2 , No. 411294 ) for the scholarship provided to pursue a PhD in Chemistry at the University of Southampton. The authors acknowledge Prof. Philip Bartlett and Derek Pletcher for enlightening discussions. Publisher Copyright: © 2021 Elsevier B.V.
Keywords: SCV, SQV, Sampled current voltammetry, electron transfer kinetics, sampled charge voltacoulommetry

Identifiers

Local EPrints ID: 446423
URI: http://eprints.soton.ac.uk/id/eprint/446423
ISSN: 1572-6657
PURE UUID: c72a7327-c18c-4fde-9d3d-2ee7414ff043
ORCID for Guy Denuault: ORCID iD orcid.org/0000-0002-8630-9492

Catalogue record

Date deposited: 09 Feb 2021 17:30
Last modified: 17 Mar 2024 06:16

Export record

Altmetrics

Contributors

Author: Oliver Rodriguez Martinez
Author: Guy Denuault ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×