It's worth cleaning – The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty
It's worth cleaning – The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty
Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28–32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
ARMD, Adverse reaction to metal debris, Metal-on-metal, THR, Total hip replacement, Trunnionosis
Buchner, Mara
c5807cdf-bb1c-4e7c-a018-0a1c8e653d3e
Cook, Richard
06f8322d-81be-4f82-9326-19e55541c78f
Dommann-Scherrer, Corina
3273ca53-bc87-4cff-98f1-f82122f44b90
Meier, Christoph
5de3d353-3781-4ff9-bc30-72497f942bd9
Dommann, Alex
9ab64185-1dfc-46c6-a877-765e6f706092
Wahl, Peter
a8819d53-d2e9-49ab-a1cb-96266ffc7b61
1 March 2021
Buchner, Mara
c5807cdf-bb1c-4e7c-a018-0a1c8e653d3e
Cook, Richard
06f8322d-81be-4f82-9326-19e55541c78f
Dommann-Scherrer, Corina
3273ca53-bc87-4cff-98f1-f82122f44b90
Meier, Christoph
5de3d353-3781-4ff9-bc30-72497f942bd9
Dommann, Alex
9ab64185-1dfc-46c6-a877-765e6f706092
Wahl, Peter
a8819d53-d2e9-49ab-a1cb-96266ffc7b61
Buchner, Mara, Cook, Richard, Dommann-Scherrer, Corina, Meier, Christoph, Dommann, Alex and Wahl, Peter
(2021)
It's worth cleaning – The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty.
Journal of the Mechanical Behavior of Biomedical Materials, 115, [104304].
(doi:10.1016/j.jmbbm.2020.104304).
Abstract
Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28–32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
Text
CaseRepTrunnionosis 201122 JMBBM_12.01.2021
- Accepted Manuscript
More information
Accepted/In Press date: 29 December 2020
e-pub ahead of print date: 6 January 2021
Published date: 1 March 2021
Keywords:
ARMD, Adverse reaction to metal debris, Metal-on-metal, THR, Total hip replacement, Trunnionosis
Identifiers
Local EPrints ID: 446483
URI: http://eprints.soton.ac.uk/id/eprint/446483
ISSN: 1751-6161
PURE UUID: ca0a689a-5649-409c-bc28-7919ce79aee3
Catalogue record
Date deposited: 11 Feb 2021 17:31
Last modified: 17 Mar 2024 06:15
Export record
Altmetrics
Contributors
Author:
Mara Buchner
Author:
Corina Dommann-Scherrer
Author:
Christoph Meier
Author:
Alex Dommann
Author:
Peter Wahl
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics