The determination of the isotopic composition of Cu and Zn in seawater
The determination of the isotopic composition of Cu and Zn in seawater
The stable isotope compositions of Zn and Cu in natural materials are newly available for measurement with the advent of multiple-collector inductively coupled mass spectrometry (MC–ICPMS). Although the oceans are prime scientific targets, no progress has been made as yet because of considerable analytical challenges involving the low concentrations of these elements in seawater. We present a procedure which allows isotopic analysis of Zn and Cu isotope compositions of seawater samples at least 1 L in size by MC ICPMS.
The main difficulty in analysing Zn and Cu isotopes from seawater samples is their low concentrations (nM/kg) in a matrix with much higher concentrations of other elements. We have surmounted these problems using a procedure that involves pre-concentration using either a BioRad Chelex®100 column or co-precipitation, followed by further purification and separation of Cu and Zn on an anion column. The major advantage of co-precipitation is that the blank is low and allows the precise isotopic analysis of even the most Zn-depleted surface ocean samples. Zn samples have been analysed using a double spike in order to correct for analytical mass discrimination. This approach has been tested using standard-doped seawater samples that had previously been stripped of their metal contents using the Chelex column. The approach is highly successful and yields ?66Zn = ? 0.02 ± 0.05‰ (n = 5) relative to the standard dopant. For multiple analyses of a large sample of the English Channel we obtain a result for ?66Zn of 0.35 ± 0.08‰ (n = 11) for Chelex extraction and 0.31 ± 0.04‰ (n = 5) for co-precipitation. For both Cu and Zn, correction for instrumental mass discrimination using standard-bracketing requires some care to overcome artefacts-related sample introduction into the mass spectrometer.
A depth profile from the NE Pacific is also presented. Measured concentrations are very similar to those reported elsewhere. Cu and Zn isotopes in the upper 400 m of the water column are anti-correlated and may reflect the dominance of scavenging for Cu and biological recycling for Zn.
zinc, copper, isotope composition, mass spectrometry, double spike, seawater
280-297
Bermin, J.
a12c899d-e71c-475b-a9eb-11fde1865c5b
Vance, D.
2cc02d9f-ca79-457f-b1fa-ca1e5e2a4d0e
Archer, C.
0f61fde3-d0e0-4197-a63a-24858f8afdf5
Statham, P.J.
51458f15-d6e2-4231-8bba-d0567f9e440c
2006
Bermin, J.
a12c899d-e71c-475b-a9eb-11fde1865c5b
Vance, D.
2cc02d9f-ca79-457f-b1fa-ca1e5e2a4d0e
Archer, C.
0f61fde3-d0e0-4197-a63a-24858f8afdf5
Statham, P.J.
51458f15-d6e2-4231-8bba-d0567f9e440c
Bermin, J., Vance, D., Archer, C. and Statham, P.J.
(2006)
The determination of the isotopic composition of Cu and Zn in seawater.
Chemical Geology, 226 (3-4), .
(doi:10.1016/j.chemgeo.2005.09.025).
Abstract
The stable isotope compositions of Zn and Cu in natural materials are newly available for measurement with the advent of multiple-collector inductively coupled mass spectrometry (MC–ICPMS). Although the oceans are prime scientific targets, no progress has been made as yet because of considerable analytical challenges involving the low concentrations of these elements in seawater. We present a procedure which allows isotopic analysis of Zn and Cu isotope compositions of seawater samples at least 1 L in size by MC ICPMS.
The main difficulty in analysing Zn and Cu isotopes from seawater samples is their low concentrations (nM/kg) in a matrix with much higher concentrations of other elements. We have surmounted these problems using a procedure that involves pre-concentration using either a BioRad Chelex®100 column or co-precipitation, followed by further purification and separation of Cu and Zn on an anion column. The major advantage of co-precipitation is that the blank is low and allows the precise isotopic analysis of even the most Zn-depleted surface ocean samples. Zn samples have been analysed using a double spike in order to correct for analytical mass discrimination. This approach has been tested using standard-doped seawater samples that had previously been stripped of their metal contents using the Chelex column. The approach is highly successful and yields ?66Zn = ? 0.02 ± 0.05‰ (n = 5) relative to the standard dopant. For multiple analyses of a large sample of the English Channel we obtain a result for ?66Zn of 0.35 ± 0.08‰ (n = 11) for Chelex extraction and 0.31 ± 0.04‰ (n = 5) for co-precipitation. For both Cu and Zn, correction for instrumental mass discrimination using standard-bracketing requires some care to overcome artefacts-related sample introduction into the mass spectrometer.
A depth profile from the NE Pacific is also presented. Measured concentrations are very similar to those reported elsewhere. Cu and Zn isotopes in the upper 400 m of the water column are anti-correlated and may reflect the dominance of scavenging for Cu and biological recycling for Zn.
This record has no associated files available for download.
More information
Published date: 2006
Keywords:
zinc, copper, isotope composition, mass spectrometry, double spike, seawater
Identifiers
Local EPrints ID: 44740
URI: http://eprints.soton.ac.uk/id/eprint/44740
ISSN: 0009-2541
PURE UUID: f998b693-cd6f-4302-9899-96b0f3ecd3ee
Catalogue record
Date deposited: 09 Mar 2007
Last modified: 15 Mar 2024 09:07
Export record
Altmetrics
Contributors
Author:
J. Bermin
Author:
D. Vance
Author:
C. Archer
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics