The University of Southampton
University of Southampton Institutional Repository

Understanding viscous magnetization of multidomain magnetite

Understanding viscous magnetization of multidomain magnetite
Understanding viscous magnetization of multidomain magnetite
Viscous magnetization (VM) and viscous remanent magnetization (VRM) have been measured, as a function of temperature, between room temperature and the Curie temperature using a suite of well-characterized synthetic and natural multidomain (MD) magnetite samples. Particular attention was given to possible diffusion aftereffects such as dislocation creep (stress relaxation) and disaccommodation (vacancy and ionic reordering) and their contribution to viscous behavior in what has been commonly thought of as a purely thermal fluctuation process. Dislocation creep was examined by measuring viscosity before and after annealing. Annealing was found to reduce the non-log(t) behavior, where t is time. Non-log(t) behavior has been associated with diffusion aftereffects, suggesting that these are a major contributor to viscosity and (de)magnetization processes in MD samples. The positive curvature of the non-log(t) acquisition processes indicates that dislocation creep dominates over disaccommodation. This does not imply that VM and VRM are due solely to dislocation creep, but rather that VRM and VM reflect a number of unrelated temperature-dependent processes, primarily thermal fluctuations and dislocation creep. This is the first time that dislocation creep has been directly identified as contributing to viscosity at temperature. These findings will have particular implications for paleointensity determinations, as on heating a sample, its dislocation structure may relax, giving rise to demagnetizations not associated with thermal fluctuations. This will lead to incorrect intensity estimates. If no heating is performed on a geological specimen, then it is very likely that laboratory timescale stress relaxation processes will have already occurred in situ.
magnetization, multidomain, magnetite
0148-0227
B02102
Williams, W.
35cc0979-e4c5-4438-a7bb-10d1fd5653d0
Muxworthy, A.R.
931b5755-e923-4995-957f-6af47c5ba6b4
Williams, W.
35cc0979-e4c5-4438-a7bb-10d1fd5653d0
Muxworthy, A.R.
931b5755-e923-4995-957f-6af47c5ba6b4

Williams, W. and Muxworthy, A.R. (2006) Understanding viscous magnetization of multidomain magnetite. Journal of Geophysical Research, 111 (B2), B02102. (doi:10.1029/2005JB003695).

Record type: Article

Abstract

Viscous magnetization (VM) and viscous remanent magnetization (VRM) have been measured, as a function of temperature, between room temperature and the Curie temperature using a suite of well-characterized synthetic and natural multidomain (MD) magnetite samples. Particular attention was given to possible diffusion aftereffects such as dislocation creep (stress relaxation) and disaccommodation (vacancy and ionic reordering) and their contribution to viscous behavior in what has been commonly thought of as a purely thermal fluctuation process. Dislocation creep was examined by measuring viscosity before and after annealing. Annealing was found to reduce the non-log(t) behavior, where t is time. Non-log(t) behavior has been associated with diffusion aftereffects, suggesting that these are a major contributor to viscosity and (de)magnetization processes in MD samples. The positive curvature of the non-log(t) acquisition processes indicates that dislocation creep dominates over disaccommodation. This does not imply that VM and VRM are due solely to dislocation creep, but rather that VRM and VM reflect a number of unrelated temperature-dependent processes, primarily thermal fluctuations and dislocation creep. This is the first time that dislocation creep has been directly identified as contributing to viscosity at temperature. These findings will have particular implications for paleointensity determinations, as on heating a sample, its dislocation structure may relax, giving rise to demagnetizations not associated with thermal fluctuations. This will lead to incorrect intensity estimates. If no heating is performed on a geological specimen, then it is very likely that laboratory timescale stress relaxation processes will have already occurred in situ.

This record has no associated files available for download.

More information

Published date: 2006
Keywords: magnetization, multidomain, magnetite

Identifiers

Local EPrints ID: 44743
URI: http://eprints.soton.ac.uk/id/eprint/44743
ISSN: 0148-0227
PURE UUID: ee1ad1ff-edd9-4801-ba92-9a645e8c4001

Catalogue record

Date deposited: 09 Mar 2007
Last modified: 15 Mar 2024 09:07

Export record

Altmetrics

Contributors

Author: W. Williams
Author: A.R. Muxworthy

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×