Temporal response of magnitude distribution to fluid injection rates in The Geysers geothermal field
Temporal response of magnitude distribution to fluid injection rates in The Geysers geothermal field
The influence of fluid injection rates on the magnitude distribution of the seismicity which occurred in the NW part of The Geysers geothermal site is studied here. A direct comparison between injection rate changes and b value response is attempted after appropriate selection of data subsets. Due to the relatively small sample (1121 events, corresponding to an average rate of ~ 0.45 events/day), we also aggregated seismic activity into two families corresponding to increasing and decreasing injection rates, respectively. The b values were calculated as a function of time lag related to the injection activity. In agreement with previous studies, we found a statistically significant direct relation between b values and injection rate changes, which occurred at a zero or very short time lag (from 0 to ~ 15 days). However, the b value changes are related to the slope (i.e., the second derivative of injection volume), instead of the absolute values of injection rates. The increasing injection rates correspond to b = 1.18 ± 0.06, whereas the decreasing injection rates correspond to b = 1.10 ± 0.05. The corresponding values estimated by the repeated medians technique are b = 1.97 ± 0.20 and b = 1.50 ± 0.13. Both differences are significant at 0.05 level.
327-339
Leptokaropoulos, K.
6176f4d8-7af0-4575-bf2c-5aaba3d182ce
Staszek, M.
5927159b-a584-40de-a8b8-0dbeae0c5f36
30 October 2019
Leptokaropoulos, K.
6176f4d8-7af0-4575-bf2c-5aaba3d182ce
Staszek, M.
5927159b-a584-40de-a8b8-0dbeae0c5f36
Leptokaropoulos, K. and Staszek, M.
(2019)
Temporal response of magnitude distribution to fluid injection rates in The Geysers geothermal field.
Acta Geophysica, 67, .
(doi:10.1007/s11600-018-0215-1).
Abstract
The influence of fluid injection rates on the magnitude distribution of the seismicity which occurred in the NW part of The Geysers geothermal site is studied here. A direct comparison between injection rate changes and b value response is attempted after appropriate selection of data subsets. Due to the relatively small sample (1121 events, corresponding to an average rate of ~ 0.45 events/day), we also aggregated seismic activity into two families corresponding to increasing and decreasing injection rates, respectively. The b values were calculated as a function of time lag related to the injection activity. In agreement with previous studies, we found a statistically significant direct relation between b values and injection rate changes, which occurred at a zero or very short time lag (from 0 to ~ 15 days). However, the b value changes are related to the slope (i.e., the second derivative of injection volume), instead of the absolute values of injection rates. The increasing injection rates correspond to b = 1.18 ± 0.06, whereas the decreasing injection rates correspond to b = 1.10 ± 0.05. The corresponding values estimated by the repeated medians technique are b = 1.97 ± 0.20 and b = 1.50 ± 0.13. Both differences are significant at 0.05 level.
This record has no associated files available for download.
More information
Published date: 30 October 2019
Identifiers
Local EPrints ID: 448095
URI: http://eprints.soton.ac.uk/id/eprint/448095
ISSN: 1895-6572
PURE UUID: 4c40586e-4109-482d-b058-d7e3df9ff0f8
Catalogue record
Date deposited: 01 Apr 2021 15:58
Last modified: 17 Mar 2024 04:05
Export record
Altmetrics
Contributors
Author:
M. Staszek
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics