The University of Southampton
University of Southampton Institutional Repository

Effect of posterior donor lenticule thickness on optical abberations and visual outcome with time after descemet stripping endothelial Kkeratoplasty (DSEK)

Effect of posterior donor lenticule thickness on optical abberations and visual outcome with time after descemet stripping endothelial Kkeratoplasty (DSEK)
Effect of posterior donor lenticule thickness on optical abberations and visual outcome with time after descemet stripping endothelial Kkeratoplasty (DSEK)
Purpose: : To evaluate optical and visual outcomes of DSEK as a function of time. Methods: : Fifty-one eyes from 50 consecutive patients who underwent DSEK for Fuchs’ endothelial dystrophy and pseudophakic bullous keratopathy and had been followed up for > 12 months (mean=12.43 months) were identified retrospectively. All donor lenticules were prepared manually. Pre and post surgical data analysed included best corrected LogMAR acuity, manifest refraction, central corneal thickness, endothelial graft thickness (Zeiss Visante AS-OCT), corneal wavefront ocular aberrometry (root mean square values for higher order, lower order and total astigmatism in the central 4mm, 5mm and 6mm areas using Zeiss-Atlas Omni corneal topography) and total aberration using Shack-Hartman wavefront analysis (AMO-VisX Wavescan). Statistical analysis was performed using SPSS v17. Results: Mean age of our cohort was 73.4 years (n=50). Mean spherical and cylindrical error did not change significantly post DSEK (0.77 ± 1.44 DS and -1.75 ± 1.81 DC versus 1.06 ± 2.7 DS and -1.80 ± 2.5 DC pre DSEK). Visual acuity improved from a mean of 0.97 ± 0.54 logMAR to 0.66 ± 0.55 logMAR (P<0.0001). Post DSEK root mean square values for total aberrations ranged from 1.22 µm to 2.68 µm, while values for higher order abberations ranged from 0.61 µm to 1.73 µm (n=19). Corneal thickness reduced from a mean of 637 µ to 525 µ (P<0.0001). Median donor lenticule thickness was 269 µ at month 1, 247 µ at month 3, 232 µ at month 6 and 143 µ at last follow up (range = 52µ to 290µ) with an average diameter of 9.04 ± 0.41 mm. No statistical correlation could be found between donor lenticule thickness and ocular abberations or between lenticule thickness and visual outcomes. Conclusions: This is the first study to examine posterior lenticule thickness using AS-OCT and explore the relationship with corneal HOA and refractive and visual outcomes over time. DSEK donor lenticular thickness varied significantly with time. Correlation with refractive metrics including corneal aberration, total HOA and refractive status are discussed. Defocus and astigmatism did not change significantly one year post DSEK compared with pre-operative values whilst visual acuity improved significantly. Lenticule thickness measured by AS-OCT after one year in-situ did not correlate with optical aberration, refractive or visual outcome.
0146-0404
Goverdhan, Srinivas V
9ae32d5a-5c82-48a4-962d-1ed8acc3991e
Konstantopoulos, Aristides
c54185a9-1ef3-4b6d-91a3-38de444cc4fb
Elsahn, Ahmad
db5d3c4e-61a6-4069-8a20-64b077127ca6
Anderson, David F.
4cf6cabc-081a-48b5-98bf-5fabe7d184d5
Hossain, Parwez
563de5fc-84ad-4539-9228-bde0237eaf51
Goverdhan, Srinivas V
9ae32d5a-5c82-48a4-962d-1ed8acc3991e
Konstantopoulos, Aristides
c54185a9-1ef3-4b6d-91a3-38de444cc4fb
Elsahn, Ahmad
db5d3c4e-61a6-4069-8a20-64b077127ca6
Anderson, David F.
4cf6cabc-081a-48b5-98bf-5fabe7d184d5
Hossain, Parwez
563de5fc-84ad-4539-9228-bde0237eaf51

Goverdhan, Srinivas V, Konstantopoulos, Aristides, Elsahn, Ahmad, Anderson, David F. and Hossain, Parwez (2011) Effect of posterior donor lenticule thickness on optical abberations and visual outcome with time after descemet stripping endothelial Kkeratoplasty (DSEK). Investigative Ophthalmology & Visual Science, 52 (14), [783].

Record type: Meeting abstract

Abstract

Purpose: : To evaluate optical and visual outcomes of DSEK as a function of time. Methods: : Fifty-one eyes from 50 consecutive patients who underwent DSEK for Fuchs’ endothelial dystrophy and pseudophakic bullous keratopathy and had been followed up for > 12 months (mean=12.43 months) were identified retrospectively. All donor lenticules were prepared manually. Pre and post surgical data analysed included best corrected LogMAR acuity, manifest refraction, central corneal thickness, endothelial graft thickness (Zeiss Visante AS-OCT), corneal wavefront ocular aberrometry (root mean square values for higher order, lower order and total astigmatism in the central 4mm, 5mm and 6mm areas using Zeiss-Atlas Omni corneal topography) and total aberration using Shack-Hartman wavefront analysis (AMO-VisX Wavescan). Statistical analysis was performed using SPSS v17. Results: Mean age of our cohort was 73.4 years (n=50). Mean spherical and cylindrical error did not change significantly post DSEK (0.77 ± 1.44 DS and -1.75 ± 1.81 DC versus 1.06 ± 2.7 DS and -1.80 ± 2.5 DC pre DSEK). Visual acuity improved from a mean of 0.97 ± 0.54 logMAR to 0.66 ± 0.55 logMAR (P<0.0001). Post DSEK root mean square values for total aberrations ranged from 1.22 µm to 2.68 µm, while values for higher order abberations ranged from 0.61 µm to 1.73 µm (n=19). Corneal thickness reduced from a mean of 637 µ to 525 µ (P<0.0001). Median donor lenticule thickness was 269 µ at month 1, 247 µ at month 3, 232 µ at month 6 and 143 µ at last follow up (range = 52µ to 290µ) with an average diameter of 9.04 ± 0.41 mm. No statistical correlation could be found between donor lenticule thickness and ocular abberations or between lenticule thickness and visual outcomes. Conclusions: This is the first study to examine posterior lenticule thickness using AS-OCT and explore the relationship with corneal HOA and refractive and visual outcomes over time. DSEK donor lenticular thickness varied significantly with time. Correlation with refractive metrics including corneal aberration, total HOA and refractive status are discussed. Defocus and astigmatism did not change significantly one year post DSEK compared with pre-operative values whilst visual acuity improved significantly. Lenticule thickness measured by AS-OCT after one year in-situ did not correlate with optical aberration, refractive or visual outcome.

This record has no associated files available for download.

More information

Published date: April 2011

Identifiers

Local EPrints ID: 448109
URI: http://eprints.soton.ac.uk/id/eprint/448109
ISSN: 0146-0404
PURE UUID: b6eb9432-94af-4ad8-942a-7e54693682f1
ORCID for Parwez Hossain: ORCID iD orcid.org/0000-0002-3131-2395

Catalogue record

Date deposited: 01 Apr 2021 15:59
Last modified: 17 Mar 2024 03:04

Export record

Contributors

Author: Srinivas V Goverdhan
Author: Aristides Konstantopoulos
Author: Ahmad Elsahn
Author: David F. Anderson
Author: Parwez Hossain ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×