A correlation analysis between injection rates and magnitude distribution in the geysers geothermal field
A correlation analysis between injection rates and magnitude distribution in the geysers geothermal field
The magnitude distribution variation in the north western part of The Geysers geothermal field is studied. Various types of b-value analysis are performed in order to investigate thoroughly the impact of fluid injection to magnitude distribution. Other parameters such as distance from the open hole of the injection well are also investigated. The analysis performed in this study indicated that b-values are significantly positively correlated to injection rate fluctuations whereas no significant influence of the seismicity rates and the distance from the injection well on b-values was detected.
European Association of Geoscientists and Engineers
Leptokaropoulos, K.
6176f4d8-7af0-4575-bf2c-5aaba3d182ce
Cielesta, S.
c7883bde-2016-4f98-8f9d-01d088b2ed4c
Staszek, M.
5927159b-a584-40de-a8b8-0dbeae0c5f36
March 2018
Leptokaropoulos, K.
6176f4d8-7af0-4575-bf2c-5aaba3d182ce
Cielesta, S.
c7883bde-2016-4f98-8f9d-01d088b2ed4c
Staszek, M.
5927159b-a584-40de-a8b8-0dbeae0c5f36
Leptokaropoulos, K., Cielesta, S. and Staszek, M.
(2018)
A correlation analysis between injection rates and magnitude distribution in the geysers geothermal field.
In 7th EAGE Workshop on Passive Seismic 2018.
European Association of Geoscientists and Engineers..
Record type:
Conference or Workshop Item
(Paper)
Abstract
The magnitude distribution variation in the north western part of The Geysers geothermal field is studied. Various types of b-value analysis are performed in order to investigate thoroughly the impact of fluid injection to magnitude distribution. Other parameters such as distance from the open hole of the injection well are also investigated. The analysis performed in this study indicated that b-values are significantly positively correlated to injection rate fluctuations whereas no significant influence of the seismicity rates and the distance from the injection well on b-values was detected.
This record has no associated files available for download.
More information
Published date: March 2018
Identifiers
Local EPrints ID: 448227
URI: http://eprints.soton.ac.uk/id/eprint/448227
PURE UUID: 3f6d7668-335f-43a7-917f-1664d14cae4f
Catalogue record
Date deposited: 15 Apr 2021 16:33
Last modified: 23 Feb 2023 03:23
Export record
Contributors
Author:
S. Cielesta
Author:
M. Staszek
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics