Objective quantitative analysis of eosinophils and bronchial epithelial cells in induced sputum by laser scanning cytometry
Objective quantitative analysis of eosinophils and bronchial epithelial cells in induced sputum by laser scanning cytometry
Background - Sputum induction is an important non-invasive technique for measuring airway inflammation in asthma. Cell numbers are often too low for flow cytometric analysis. Laser scanning cytometry (LSC) is a novel technique that allows objective multicolour fluorescence analysis of cells on a microscope slide. Methods - LSC was used to determine sputum eosinophil and bronchial epithelial cell counts. We first confirmed that we could measure eosinophil counts accurately in peripheral blood using α-major basic protein (MBP) immunofluorescent staining. Sputum induction was performed according to standard protocols. Sputum samples from eight normal controls and 12 asthmatic patients were analysed by LSC and manual counting by two independent observers. Octospot cytospins were fixed and stained with mouse-α-human-MBP monoclonal antibody or mouse-α-human-cytokeratin antibody and goat-α-mouse Oregon Green conjugated second antibody. Results - Sputum induction provided a mean (SE) of 0.99 (0.2) x 106 cells per donor. More than 3000 cells on three cytospins per slide were analysed per cell type. The intraclass correlation coefficient (R) and standard deviation (SD) of differences in eosinophils determined by manual counting and LSC were 0.9 and 2.1, respectively, and for bronchial epithelial cell counts they were 0.7 and 2.0. Selective detection of labelled cells was confirmed visually after relocation. Conclusion - Eosinophils and bronchial epithelial cells can be accurately and reproducibly counted in an objective manner. LSC is therefore a potentially powerful new method for immunophenotyping leucocytes and epithelial cells objectively in induced sputum in patients with asthma.
Image analysis, Induced sputum, Laser scanning cytometry
124-130
Woltmann, G.
51d70e50-a7a2-4f32-8708-6c3c8f8f5a5b
Ward, R. J.
ec3f37b6-4542-4b66-811a-a6674d9d8b91
Symon, F. A.
14302398-2306-4740-b6d2-b86cc7b20f34
Rew, D. A.
36dcc3ad-2379-4b61-a468-5c623d796887
Pavord, I. D.
9718f25b-b28d-47d2-b19d-6c5ead4f1717
Wardlaw, A. J.
4fcd092d-61df-4eae-a5f6-50c506fe6a64
1 February 1999
Woltmann, G.
51d70e50-a7a2-4f32-8708-6c3c8f8f5a5b
Ward, R. J.
ec3f37b6-4542-4b66-811a-a6674d9d8b91
Symon, F. A.
14302398-2306-4740-b6d2-b86cc7b20f34
Rew, D. A.
36dcc3ad-2379-4b61-a468-5c623d796887
Pavord, I. D.
9718f25b-b28d-47d2-b19d-6c5ead4f1717
Wardlaw, A. J.
4fcd092d-61df-4eae-a5f6-50c506fe6a64
Woltmann, G., Ward, R. J., Symon, F. A., Rew, D. A., Pavord, I. D. and Wardlaw, A. J.
(1999)
Objective quantitative analysis of eosinophils and bronchial epithelial cells in induced sputum by laser scanning cytometry.
Thorax, 54 (2), .
(doi:10.1136/thx.54.2.124).
Abstract
Background - Sputum induction is an important non-invasive technique for measuring airway inflammation in asthma. Cell numbers are often too low for flow cytometric analysis. Laser scanning cytometry (LSC) is a novel technique that allows objective multicolour fluorescence analysis of cells on a microscope slide. Methods - LSC was used to determine sputum eosinophil and bronchial epithelial cell counts. We first confirmed that we could measure eosinophil counts accurately in peripheral blood using α-major basic protein (MBP) immunofluorescent staining. Sputum induction was performed according to standard protocols. Sputum samples from eight normal controls and 12 asthmatic patients were analysed by LSC and manual counting by two independent observers. Octospot cytospins were fixed and stained with mouse-α-human-MBP monoclonal antibody or mouse-α-human-cytokeratin antibody and goat-α-mouse Oregon Green conjugated second antibody. Results - Sputum induction provided a mean (SE) of 0.99 (0.2) x 106 cells per donor. More than 3000 cells on three cytospins per slide were analysed per cell type. The intraclass correlation coefficient (R) and standard deviation (SD) of differences in eosinophils determined by manual counting and LSC were 0.9 and 2.1, respectively, and for bronchial epithelial cell counts they were 0.7 and 2.0. Selective detection of labelled cells was confirmed visually after relocation. Conclusion - Eosinophils and bronchial epithelial cells can be accurately and reproducibly counted in an objective manner. LSC is therefore a potentially powerful new method for immunophenotyping leucocytes and epithelial cells objectively in induced sputum in patients with asthma.
This record has no associated files available for download.
More information
Published date: 1 February 1999
Additional Information:
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
Keywords:
Image analysis, Induced sputum, Laser scanning cytometry
Identifiers
Local EPrints ID: 449490
URI: http://eprints.soton.ac.uk/id/eprint/449490
ISSN: 0040-6376
PURE UUID: 08ed17a6-d9d4-43c0-bb50-e3acef302805
Catalogue record
Date deposited: 03 Jun 2021 16:30
Last modified: 17 Mar 2024 03:56
Export record
Altmetrics
Contributors
Author:
G. Woltmann
Author:
R. J. Ward
Author:
F. A. Symon
Author:
I. D. Pavord
Author:
A. J. Wardlaw
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics