The present study, reports on the findings of connecting 2 stacks of 48 MFCs and the importance of maturity and acclimation for the anodic biofilms. Furthermore, an attempt is made to emphasize the importance of a universal unit for quantifying power output. Finally, this paper presents data from the smallest MFCs, specifically designed for wastewater treatment. The main aims of this study were to (1) configure a high number of small-scale MFCs (48) to run as a stack for a long period of time (2-years); (2) repeat this process with a new set of MFCs configured as a stack of equal dimensions (units) and compare individual as well as stack performances of both old and new MFC, through polarization experiments under identical conditions; (3) normalize and compare the recorded power output according to the plethora of methods reported in the literature; (4) design even smaller MFCs and investigate their performance.
1-9
The Electrochemical Society
Ieropoulos, I. A.
6c580270-3e08-430a-9f49-7fbe869daf13
Winfield, J.
e81f4fad-1433-4c6a-9723-24a14f172896
Greenman, J.
eb3d9b82-7cac-4442-9301-f34884ae4a16
Melhuish, C.
b810405f-9492-42d0-b8b7-8712ab11536c
2010
Ieropoulos, I. A.
6c580270-3e08-430a-9f49-7fbe869daf13
Winfield, J.
e81f4fad-1433-4c6a-9723-24a14f172896
Greenman, J.
eb3d9b82-7cac-4442-9301-f34884ae4a16
Melhuish, C.
b810405f-9492-42d0-b8b7-8712ab11536c
Ieropoulos, I. A., Winfield, J., Greenman, J. and Melhuish, C.
(2010)
Small scale microbial fuel cells and different ways of reporting output.
In Biological Fuel Cells 4.
vol. 28,
The Electrochemical Society.
.
(doi:10.1149/1.3492221).
Record type:
Conference or Workshop Item
(Paper)
Abstract
The present study, reports on the findings of connecting 2 stacks of 48 MFCs and the importance of maturity and acclimation for the anodic biofilms. Furthermore, an attempt is made to emphasize the importance of a universal unit for quantifying power output. Finally, this paper presents data from the smallest MFCs, specifically designed for wastewater treatment. The main aims of this study were to (1) configure a high number of small-scale MFCs (48) to run as a stack for a long period of time (2-years); (2) repeat this process with a new set of MFCs configured as a stack of equal dimensions (units) and compare individual as well as stack performances of both old and new MFC, through polarization experiments under identical conditions; (3) normalize and compare the recorded power output according to the plethora of methods reported in the literature; (4) design even smaller MFCs and investigate their performance.
This record has no associated files available for download.
More information
Published date: 2010
Additional Information:
Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
Identifiers
Local EPrints ID: 454622
URI: http://eprints.soton.ac.uk/id/eprint/454622
ISSN: 1938-5862
PURE UUID: 6fc3209d-135a-4adc-8d02-23fc2569307f
Catalogue record
Date deposited: 17 Feb 2022 17:39
Last modified: 06 Jun 2024 02:12
Export record
Altmetrics
Contributors
Author:
J. Winfield
Author:
J. Greenman
Author:
C. Melhuish
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics