Dataset for the article: "Measured Behaviour of a Memristor-Based Tuneable Instrumentation Amplifier"
Dataset for the article: "Measured Behaviour of a Memristor-Based Tuneable Instrumentation Amplifier"
The excel file includes the measured data used for generating the Fig 2 to 5 in the paper 'Measured Behaviour of a Memristor-Based Tuneable Instrumentation Amplifier'.
The PNG file inclues the Fig 2 to 5 in the paper which were generated based on the data in the excel file. The figures are as follows:
Fig2. Impedance-frequency function of TiOx/Al2O3 10×10µm2 memristor devices.
Fig3. Gain response of the instrumentation amplifier for a set of memristor resistances and a based line given by 30kΩ discrete resistor.
Fig4. THD+N of the instrumentation amplifier with input signal amplitude from 30mV to 300mV.
Fig5. THD+N of the instrumentation amplifier uses 3 memristors compare with uses 1 memristor.
memrsitor, instrumentation amplifier
University of Southampton
Yang, Fan
6db7f8d2-9649-4bcb-ad3d-5d7af936fb9a
Serb, Alexantrou
30f5ec26-f51d-42b3-85fd-0325a27a792c
Prodromakis, Themis
d58c9c10-9d25-4d22-b155-06c8437acfbf
Yang, Fan
6db7f8d2-9649-4bcb-ad3d-5d7af936fb9a
Serb, Alexantrou
30f5ec26-f51d-42b3-85fd-0325a27a792c
Prodromakis, Themis
d58c9c10-9d25-4d22-b155-06c8437acfbf
Yang, Fan
(2022)
Dataset for the article: "Measured Behaviour of a Memristor-Based Tuneable Instrumentation Amplifier".
University of Southampton
doi:10.5258/SOTON/D2207
[Dataset]
Abstract
The excel file includes the measured data used for generating the Fig 2 to 5 in the paper 'Measured Behaviour of a Memristor-Based Tuneable Instrumentation Amplifier'.
The PNG file inclues the Fig 2 to 5 in the paper which were generated based on the data in the excel file. The figures are as follows:
Fig2. Impedance-frequency function of TiOx/Al2O3 10×10µm2 memristor devices.
Fig3. Gain response of the instrumentation amplifier for a set of memristor resistances and a based line given by 30kΩ discrete resistor.
Fig4. THD+N of the instrumentation amplifier with input signal amplitude from 30mV to 300mV.
Fig5. THD+N of the instrumentation amplifier uses 3 memristors compare with uses 1 memristor.
Spreadsheet
dataset_for_memristor_based_instrumentation_amplifier.xlsx
- Dataset
Image
Fig_2_to_5_dataset.png
- Image
More information
Published date: 12 May 2022
Keywords:
memrsitor, instrumentation amplifier
Identifiers
Local EPrints ID: 456741
URI: http://eprints.soton.ac.uk/id/eprint/456741
PURE UUID: c7183019-3734-4fa9-96f6-4f5c55fc3602
Catalogue record
Date deposited: 10 May 2022 16:45
Last modified: 05 May 2023 19:37
Export record
Altmetrics
Contributors
Creator:
Fan Yang
Research team head:
Alexantrou Serb
Research team head:
Themis Prodromakis
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics