Effects of Annealed Treatment on Structure and Performance of WC-DLC Films
Effects of Annealed Treatment on Structure and Performance of WC-DLC Films
In order to study the effects of annealing on the structure and properties of WC-DLC films, WC-DLC films were deposited on the surface of high speed steel by magnetron sputtering and annealed at different temperatures. The structure, tribological properties and corrosion resistance of the WC-DLC films annealed at different temperatures were systematically characterized, respectively. The results show that the WC-DLC films are amorphous. With the increase of the annealing temperatures, the relative content of sp(3)-C decreases. WC-DLC films annealing at 250. presents the optimal friction performances with wear rate is 1.25x10(-7) mm(3)/Nm in ambient air and is 1.02x10(-7) mm(3)/Nm under deionized water. The corrosion resistance of WC-DLC film has no evident changes under 250. but degrades obviously when the annealing temperature is higher than 250 degrees C. The annealing treatment has important …
WC-DLC film, annealing treatment, friction performance, corrosion resistance performance
16-24
Liu, Zheng-bing
955006e3-d22c-4465-9135-daeee79dd57c
Zhou, Shengguo
02793824-a60e-481e-ae6e-55f2ab48e739
Wu, Yang-min
1bf801e2-568e-4ffb-9f17-1dffc3c86fc3
Wang, Shuncai
8a390e2d-6552-4c7c-a88f-25bf9d6986a6
1 June 2017
Liu, Zheng-bing
955006e3-d22c-4465-9135-daeee79dd57c
Zhou, Shengguo
02793824-a60e-481e-ae6e-55f2ab48e739
Wu, Yang-min
1bf801e2-568e-4ffb-9f17-1dffc3c86fc3
Wang, Shuncai
8a390e2d-6552-4c7c-a88f-25bf9d6986a6
Liu, Zheng-bing, Zhou, Shengguo, Wu, Yang-min and Wang, Shuncai
(2017)
Effects of Annealed Treatment on Structure and Performance of WC-DLC Films.
China Surface Engineering, 30 (3), .
(doi:10.11933/j.issn.1007−9289.20161117005).
Abstract
In order to study the effects of annealing on the structure and properties of WC-DLC films, WC-DLC films were deposited on the surface of high speed steel by magnetron sputtering and annealed at different temperatures. The structure, tribological properties and corrosion resistance of the WC-DLC films annealed at different temperatures were systematically characterized, respectively. The results show that the WC-DLC films are amorphous. With the increase of the annealing temperatures, the relative content of sp(3)-C decreases. WC-DLC films annealing at 250. presents the optimal friction performances with wear rate is 1.25x10(-7) mm(3)/Nm in ambient air and is 1.02x10(-7) mm(3)/Nm under deionized water. The corrosion resistance of WC-DLC film has no evident changes under 250. but degrades obviously when the annealing temperature is higher than 250 degrees C. The annealing treatment has important …
This record has no associated files available for download.
More information
Published date: 1 June 2017
Keywords:
WC-DLC film, annealing treatment, friction performance, corrosion resistance performance
Identifiers
Local EPrints ID: 457815
URI: http://eprints.soton.ac.uk/id/eprint/457815
PURE UUID: ee2a56e3-383e-4679-b162-0206fd83505a
Catalogue record
Date deposited: 17 Jun 2022 16:42
Last modified: 16 Mar 2024 16:33
Export record
Altmetrics
Contributors
Author:
Zheng-bing Liu
Author:
Shengguo Zhou
Author:
Yang-min Wu
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics