An active microelectrode array to detect extracellular nervous activity

An active microelectrode array to detect extracellular nervous activity
An active microelectrode array to detect extracellular nervous activity

The detection of extracellular potentials in nervous tissue using conventional methods has many limitations. In particular, it is extremely difficult to detect potentials simultaneously at more than two or three sites on one tissue preparation, and elaborate precautions are needed to reduce electrostatic interference. This thesis describes the development of an active array of nine microelectrodes with buffer amplifiers for detecting extracellular potentials. Integrated circuit technology has been used, enabling the microelectrodes and buffer amplifiers to be made on the same silicon substrate at different stages of one fabrication process. The characteristics of the interface of the evaporated gold microelectrodes and physiological saline were measured, and it was found that the interface impedance was higher than that reported for other gold electrodes. A variety of surface coatings to insulate and passivate the integrated circuit buffer amplifiers were investigated so that they could be operated submerged in saline. Connections to the buffer amplifiers were made using low resistance diffused layers coated with thermally grown silicon dioxide. Photoresist was used to insulate other parts of the circuit. The integrated buffer amplifiers were formed by using MS transistors in the source follower configuration. Each microelectrode was part of the gate electrode of an underlying transistor. The micrcroectrode array was used with off-chip voltage amplifiers and a multiplexer to permit a simultaneous display of the potentials at each electrode. In experiments with nervous tissue, results which would have been almost impossible to obtain with conventional electrodes were achieved. Experiments showed that the threshold voltages of the M S transistors in the array changed slightly during their operation in saline, but the devices performed satisfactorily throughout several hundred hours of continuous operation.

University of Southampton
Jobling, David Trevor
Jobling, David Trevor

Jobling, David Trevor (1980) An active microelectrode array to detect extracellular nervous activity. University of Southampton, Doctoral Thesis.

Record type: Thesis (Doctoral)

Abstract

The detection of extracellular potentials in nervous tissue using conventional methods has many limitations. In particular, it is extremely difficult to detect potentials simultaneously at more than two or three sites on one tissue preparation, and elaborate precautions are needed to reduce electrostatic interference. This thesis describes the development of an active array of nine microelectrodes with buffer amplifiers for detecting extracellular potentials. Integrated circuit technology has been used, enabling the microelectrodes and buffer amplifiers to be made on the same silicon substrate at different stages of one fabrication process. The characteristics of the interface of the evaporated gold microelectrodes and physiological saline were measured, and it was found that the interface impedance was higher than that reported for other gold electrodes. A variety of surface coatings to insulate and passivate the integrated circuit buffer amplifiers were investigated so that they could be operated submerged in saline. Connections to the buffer amplifiers were made using low resistance diffused layers coated with thermally grown silicon dioxide. Photoresist was used to insulate other parts of the circuit. The integrated buffer amplifiers were formed by using MS transistors in the source follower configuration. Each microelectrode was part of the gate electrode of an underlying transistor. The micrcroectrode array was used with off-chip voltage amplifiers and a multiplexer to permit a simultaneous display of the potentials at each electrode. In experiments with nervous tissue, results which would have been almost impossible to obtain with conventional electrodes were achieved. Experiments showed that the threshold voltages of the M S transistors in the array changed slightly during their operation in saline, but the devices performed satisfactorily throughout several hundred hours of continuous operation.

This record has no associated files available for download.

More information

Published date: 1980

Identifiers

Local EPrints ID: 459111
URI: http://eprints.soton.ac.uk/id/eprint/459111
PURE UUID: c6a5cc88-9f73-452c-979b-a516a11e4d17

Catalogue record

Date deposited: 04 Jul 2022 17:04
Last modified: 04 Jul 2022 17:04

Export record

Contributors

Author: David Trevor Jobling

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×