This thesis describes an effective method to suppress and control d.c. corona of coaxial gas insulating systems using resistive barriers fitted to the central conductor. Charging of these barriers reduced the field strength at the central conductor transferring the high field region to the barrier surfaces. If this field exceeds the corona inception value the discharge is limited by the resistivity of the barrier system. Various geometries were investigated some of which gave a significant improvement in corona performance. For example the corona onset voltage of a coaxial electrode system (1.6cm/58.1 cm diameter) was increased by 75% when three high resistive rods were fixed around the central conductor. In addition, a cylindrical barrier placed around the central conductor was tested. This gave a better corona performance than the rods previously used. A computer program based on the finite element method was developed in order to illustrate the basic operation of the barrier arrangement and support the experimentation in determining some of the system parameters. Correlation betwe_n experimental and computation results of electric stress distribution in the system was also performed. This thesis also describes an iterative method used using the computer program to perform the numerical integration of the equation which gave the number of electrons in an avalanche along the maximum flux line. This enabled the calculation of the critical size of avalanche which in turn gives the corona inception voltage for the system. The study was extended to include the effect of the barrier arrangement in the SF6 gas insulating system. Moreover, experimental tests and computer calculations were carried out to study the effect of protrusions on the barrier arrangement. Finally computer aided design was performed to optimise the maximum electric stress on the surface of central conductor and the barrier for various barrier voltages and goemetries.

University of Southampton
Boudjelthia, Henni
Boudjelthia, Henni

Boudjelthia, Henni (1989) Corona suppression on high voltage direct current systems. University of Southampton, Doctoral Thesis.

Record type: Thesis (Doctoral)

Abstract

This thesis describes an effective method to suppress and control d.c. corona of coaxial gas insulating systems using resistive barriers fitted to the central conductor. Charging of these barriers reduced the field strength at the central conductor transferring the high field region to the barrier surfaces. If this field exceeds the corona inception value the discharge is limited by the resistivity of the barrier system. Various geometries were investigated some of which gave a significant improvement in corona performance. For example the corona onset voltage of a coaxial electrode system (1.6cm/58.1 cm diameter) was increased by 75% when three high resistive rods were fixed around the central conductor. In addition, a cylindrical barrier placed around the central conductor was tested. This gave a better corona performance than the rods previously used. A computer program based on the finite element method was developed in order to illustrate the basic operation of the barrier arrangement and support the experimentation in determining some of the system parameters. Correlation betwe_n experimental and computation results of electric stress distribution in the system was also performed. This thesis also describes an iterative method used using the computer program to perform the numerical integration of the equation which gave the number of electrons in an avalanche along the maximum flux line. This enabled the calculation of the critical size of avalanche which in turn gives the corona inception voltage for the system. The study was extended to include the effect of the barrier arrangement in the SF6 gas insulating system. Moreover, experimental tests and computer calculations were carried out to study the effect of protrusions on the barrier arrangement. Finally computer aided design was performed to optimise the maximum electric stress on the surface of central conductor and the barrier for various barrier voltages and goemetries.

This record has no associated files available for download.

More information

Published date: 1989

Identifiers

Local EPrints ID: 461188
URI: http://eprints.soton.ac.uk/id/eprint/461188
PURE UUID: 23dcfa91-87ec-4b38-82f7-e498889049a4

Catalogue record

Date deposited: 04 Jul 2022 18:38
Last modified: 04 Jul 2022 18:38

Export record

Contributors

Author: Henni Boudjelthia

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×