The University of Southampton
University of Southampton Institutional Repository

Observations of a sweeping jet actuator for flow separation control of a backward-facing ramp

Observations of a sweeping jet actuator for flow separation control of a backward-facing ramp
Observations of a sweeping jet actuator for flow separation control of a backward-facing ramp
Flow separation control of a sweeping jet actuator in a backward-facing ramp was studied using two-dimensional and stereoscopic particle-image velocimetry. The actuator was operated at a single supply rate pertaining to a jet velocity of 7.3 m/s and positioned at the streamwise location of 0.8 and 3.7 boundary layer thickness upstream of the separating edge. Three wind tunnel reference velocities corresponding to Reynolds numbers based on the boundary layer thickness of Re δ = 2400, 5200, and 9800 (jet-to-reference velocity ratios of 1, 0.5, and 0.3) were investigated, and the control effectiveness was assessed based on the size of the separation bubble. For all three Reynolds numbers, positioning the actuator nearer to the separating edge offered poorer flow separation control for measurement planes near the jet centerline. This was attributed to the upwash effect of the jet which directed high momentum fluid away from the wall leading to lower levels of entrainment, and the formation of a localized low-pressure region that coincided with the sharp change in ramp geometry leading to stronger adverse pressure gradients and lower streamwise velocities that were more likely to undergo flow reversal. At high jet-to-reference velocity ratios, the effect was accentuated, and a secondary separation bubble was observed. When the actuator was positioned further upstream, the primary streamwise vortices produced by the sweeping jet lifted away from the wall, and secondary flow structures induced near the wall contributed to higher levels of near-wall entrainment and improved flow control along the jet centerline. In contrast, for measurement planes far from the jet centerline, positioning the actuator nearer the separating edge was preferable. This was attributed to milder decay of the primary streamwise vortices, leading to stronger downwash effect and higher entrainment levels that were able to affect a wider spanwise area.
2469-990X
Lim, Desmond
82a7e7e8-2ade-44f8-a342-a99c2b9339c4
Lyu, Zhen
4ba3e965-5744-4173-a07e-d80dee01fea1
Lim, Desmond
82a7e7e8-2ade-44f8-a342-a99c2b9339c4
Lyu, Zhen
4ba3e965-5744-4173-a07e-d80dee01fea1

Lim, Desmond and Lyu, Zhen (2021) Observations of a sweeping jet actuator for flow separation control of a backward-facing ramp. Physical Review Fluids. (doi:10.1103/PhysRevFluids.6.043902).

Record type: Article

Abstract

Flow separation control of a sweeping jet actuator in a backward-facing ramp was studied using two-dimensional and stereoscopic particle-image velocimetry. The actuator was operated at a single supply rate pertaining to a jet velocity of 7.3 m/s and positioned at the streamwise location of 0.8 and 3.7 boundary layer thickness upstream of the separating edge. Three wind tunnel reference velocities corresponding to Reynolds numbers based on the boundary layer thickness of Re δ = 2400, 5200, and 9800 (jet-to-reference velocity ratios of 1, 0.5, and 0.3) were investigated, and the control effectiveness was assessed based on the size of the separation bubble. For all three Reynolds numbers, positioning the actuator nearer to the separating edge offered poorer flow separation control for measurement planes near the jet centerline. This was attributed to the upwash effect of the jet which directed high momentum fluid away from the wall leading to lower levels of entrainment, and the formation of a localized low-pressure region that coincided with the sharp change in ramp geometry leading to stronger adverse pressure gradients and lower streamwise velocities that were more likely to undergo flow reversal. At high jet-to-reference velocity ratios, the effect was accentuated, and a secondary separation bubble was observed. When the actuator was positioned further upstream, the primary streamwise vortices produced by the sweeping jet lifted away from the wall, and secondary flow structures induced near the wall contributed to higher levels of near-wall entrainment and improved flow control along the jet centerline. In contrast, for measurement planes far from the jet centerline, positioning the actuator nearer the separating edge was preferable. This was attributed to milder decay of the primary streamwise vortices, leading to stronger downwash effect and higher entrainment levels that were able to affect a wider spanwise area.

Text
manuscript - Accepted Manuscript
Restricted to Repository staff only
Request a copy
Text
PhysRevFluids.6.043902 - Version of Record
Restricted to Repository staff only
Request a copy

More information

Accepted/In Press date: 30 March 2021
Published date: 22 April 2021

Identifiers

Local EPrints ID: 468347
URI: http://eprints.soton.ac.uk/id/eprint/468347
ISSN: 2469-990X
PURE UUID: 7f346b1a-539e-4612-8a2b-d30617546fe3
ORCID for Desmond Lim: ORCID iD orcid.org/0000-0001-6191-6803

Catalogue record

Date deposited: 10 Aug 2022 18:16
Last modified: 16 Mar 2024 21:04

Export record

Altmetrics

Contributors

Author: Desmond Lim ORCID iD
Author: Zhen Lyu

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×