Datasest in support of the publication 'A wearable insole system to measure plantar pressure and shear for people with diabetes'
Datasest in support of the publication 'A wearable insole system to measure plantar pressure and shear for people with diabetes'
Dataset in support of the journal article to be published in the journal Sensors
This dataset if available 'on request only' under a CC-BY-NC-ND licence. Please complete and return the attached form.
Description:
The excel files contain all experimental data used for generating Figure 4, Figure 5, Figure 8, Figure 9, Figure 10 and Table 1
Figure 4: (a) Applied static pressure from the Instron mechanical test machine, as a function of time. Measured pressure from the insole system and applied pressure from the test machine, obtained from the (b) static and (c) dynamic pressure test.
Figure 5: (a) Applied static shear stress from the mechanical test machine, as a function of time. Measured shear stress from the insole system and applied shear stress from the test machine, obtained from the (b) static and (c) dynamic shear test.
Figure 8: (a) Pressure, (b) medial-lateral (ML) shear and (c) anterior-posterior (AP) shear stress as a function of time from the heathy participant wearing a trainer.
Figure 9: (a) Mean peak pressure and (b) medial-lateral (ML) and (c) anterior-posterior (AP) shear stress obtained over gait cycles, with three types of footwear.
Figure 10: Mean peak plantar pressure distribution during walking obtained using XSENSOR system with and without the sensorised insole. The four sensing locations are highlighted to allow regional peak pressure value comparison.
Table 1: Peak pressure safety evaluation for 5 participants with diabetes. MPP: Mean Peak Pressure values for each participant represent the average of 10 mid-gait steps. Effect calculated as absolute pressure with sensorised insole MPP minus Without Insole MPP (S-W)
University of Southampton
Tang, Jinghua
b4b9a22c-fd6d-427a-9ab1-51184c1d2a2c
Bader, Daniel
9884d4f6-2607-4d48-bf0c-62bdcc0d1dbf
Moser, David
09874cab-348f-47f9-b018-1c2875d16998
Parker, Daniel
973ddaef-b791-4f1e-8d29-4b8c356dba72
Forghany, Saeed
3bb4ab4b-9af8-4069-b9ae-d64c1495b526
Nester, Christopher
33a8ddce-a05d-4bb3-a4fc-c30538afeaef
Jiang, Liudi
374f2414-51f0-418f-a316-e7db0d6dc4d1
Tang, Jinghua
b4b9a22c-fd6d-427a-9ab1-51184c1d2a2c
Bader, Daniel
9884d4f6-2607-4d48-bf0c-62bdcc0d1dbf
Moser, David
09874cab-348f-47f9-b018-1c2875d16998
Parker, Daniel
973ddaef-b791-4f1e-8d29-4b8c356dba72
Forghany, Saeed
3bb4ab4b-9af8-4069-b9ae-d64c1495b526
Nester, Christopher
33a8ddce-a05d-4bb3-a4fc-c30538afeaef
Jiang, Liudi
374f2414-51f0-418f-a316-e7db0d6dc4d1
Tang, Jinghua and Parker, Daniel
(2023)
Datasest in support of the publication 'A wearable insole system to measure plantar pressure and shear for people with diabetes'.
University of Southampton
doi:10.5258/SOTON/D2560
[Dataset]
Abstract
Dataset in support of the journal article to be published in the journal Sensors
This dataset if available 'on request only' under a CC-BY-NC-ND licence. Please complete and return the attached form.
Description:
The excel files contain all experimental data used for generating Figure 4, Figure 5, Figure 8, Figure 9, Figure 10 and Table 1
Figure 4: (a) Applied static pressure from the Instron mechanical test machine, as a function of time. Measured pressure from the insole system and applied pressure from the test machine, obtained from the (b) static and (c) dynamic pressure test.
Figure 5: (a) Applied static shear stress from the mechanical test machine, as a function of time. Measured shear stress from the insole system and applied shear stress from the test machine, obtained from the (b) static and (c) dynamic shear test.
Figure 8: (a) Pressure, (b) medial-lateral (ML) shear and (c) anterior-posterior (AP) shear stress as a function of time from the heathy participant wearing a trainer.
Figure 9: (a) Mean peak pressure and (b) medial-lateral (ML) and (c) anterior-posterior (AP) shear stress obtained over gait cycles, with three types of footwear.
Figure 10: Mean peak plantar pressure distribution during walking obtained using XSENSOR system with and without the sensorised insole. The four sensing locations are highlighted to allow regional peak pressure value comparison.
Table 1: Peak pressure safety evaluation for 5 participants with diabetes. MPP: Mean Peak Pressure values for each participant represent the average of 10 mid-gait steps. Effect calculated as absolute pressure with sensorised insole MPP minus Without Insole MPP (S-W)
Text
README.txt
- Dataset
Text
Request_Form_D2560.docx
- Dataset
Text
ConsentForm_clean_version.pdf
- Text
Text
ParticipantInfoSheet_Part1_clean_version.pdf
- Text
More information
Published date: 31 March 2023
Identifiers
Local EPrints ID: 475355
URI: http://eprints.soton.ac.uk/id/eprint/475355
PURE UUID: edfe6932-10eb-4691-87b6-43185d2c3079
Catalogue record
Date deposited: 16 Mar 2023 17:32
Last modified: 06 Jun 2024 01:59
Export record
Altmetrics
Contributors
Contributor:
David Moser
Creator:
Daniel Parker
Contributor:
Saeed Forghany
Research team head:
Christopher Nester
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics