The reality of myoelectric prostheses: Understanding what makes these devices difficult for some users to control

The reality of myoelectric prostheses: Understanding what makes these devices difficult for some users to control
The reality of myoelectric prostheses: Understanding what makes these devices difficult for some users to control

Users of myoelectric prostheses can often find them difficult to control. This can lead to passive-use of the device or total rejection, which can have detrimental effects on the contralateral limb due to overuse. Current clinically available prostheses are "open loop" systems, and although considerable effort has been focused on developing bio-feedback to "close the loop," there is evidence from laboratory-based studies that other factors, notably improving predictability of response, may be as, if not more, important. Interestingly, despite a large volume of research aimed at improving myoelectric pros-Theses, it is not currently known which aspect of clinically available systems has the greatest impact on overall functionality and everyday usage. A protocol has, therefore, been designed to assess electromyographic (EMG) skill of the user and predictability of the prosthesis response as significant parts of the control chain, and to relate these to functionality and everyday usage. Here, we present the protocol and results from early pilot work. A set of experiments has been developed. First, to characterize user skill in generating the required level of EMG signal, as well as the speed with which users are able to make the decision to activate the appropriate muscles. Second, to measure unpredictability introduced at the skin-electrode interface, in order to understand the effects of the socket-mounted electrode fit under different loads on the variability of time taken for the prosthetic hand to respond. To evaluate prosthesis user functionality, four different outcome measures are assessed. Using a simple upper limb functional task prosthesis users are assessed for (1) success of task completion, (2) task duration, (3) quality of movement, and (4) gaze behavior. To evaluate everyday usage away from the clinic, the symmetricity of their real-world arm use is assessed using activity monitoring. These methods will later be used to assess a prosthesis user cohort to establish the relative contribution of each control factor to the individual measures of functionality and everyday usage (using multiple regression models). The results will support future researchers, designers, and clinicians in concentrating their efforts on the area that will have the greatest impact on improving prosthesis use.

Activity monitoring, Control, Functionality assessment, Myoelectric, Prosthesis, Upper limb
Chadwell, Alix
c337930e-a6b5-43e3-8ca5-eed1d2d71340
Kenney, Laurence
83d42411-ccbe-4b21-828e-9abd9775e47d
Thies, Sibylle
233b0fa4-7a7d-4081-8e5b-5cb6126a8981
Galpin, Adam
c3157315-5bd6-4123-9044-a379ebc7ae62
Head, John
61336bc7-25a0-4a0b-ac8b-2f25e7c27405
Chadwell, Alix
c337930e-a6b5-43e3-8ca5-eed1d2d71340
Kenney, Laurence
83d42411-ccbe-4b21-828e-9abd9775e47d
Thies, Sibylle
233b0fa4-7a7d-4081-8e5b-5cb6126a8981
Galpin, Adam
c3157315-5bd6-4123-9044-a379ebc7ae62
Head, John
61336bc7-25a0-4a0b-ac8b-2f25e7c27405

Chadwell, Alix, Kenney, Laurence, Thies, Sibylle, Galpin, Adam and Head, John (2016) The reality of myoelectric prostheses: Understanding what makes these devices difficult for some users to control. Frontiers in Neurorobotics, 10 (AUG), [00007]. (doi:10.3389/fnbot.2016.00007).

Record type: Article

Abstract

Users of myoelectric prostheses can often find them difficult to control. This can lead to passive-use of the device or total rejection, which can have detrimental effects on the contralateral limb due to overuse. Current clinically available prostheses are "open loop" systems, and although considerable effort has been focused on developing bio-feedback to "close the loop," there is evidence from laboratory-based studies that other factors, notably improving predictability of response, may be as, if not more, important. Interestingly, despite a large volume of research aimed at improving myoelectric pros-Theses, it is not currently known which aspect of clinically available systems has the greatest impact on overall functionality and everyday usage. A protocol has, therefore, been designed to assess electromyographic (EMG) skill of the user and predictability of the prosthesis response as significant parts of the control chain, and to relate these to functionality and everyday usage. Here, we present the protocol and results from early pilot work. A set of experiments has been developed. First, to characterize user skill in generating the required level of EMG signal, as well as the speed with which users are able to make the decision to activate the appropriate muscles. Second, to measure unpredictability introduced at the skin-electrode interface, in order to understand the effects of the socket-mounted electrode fit under different loads on the variability of time taken for the prosthetic hand to respond. To evaluate prosthesis user functionality, four different outcome measures are assessed. Using a simple upper limb functional task prosthesis users are assessed for (1) success of task completion, (2) task duration, (3) quality of movement, and (4) gaze behavior. To evaluate everyday usage away from the clinic, the symmetricity of their real-world arm use is assessed using activity monitoring. These methods will later be used to assess a prosthesis user cohort to establish the relative contribution of each control factor to the individual measures of functionality and everyday usage (using multiple regression models). The results will support future researchers, designers, and clinicians in concentrating their efforts on the area that will have the greatest impact on improving prosthesis use.

This record has no associated files available for download.

More information

Published date: 2016
Additional Information: Publisher Copyright: © 2016 Chadwell, Kenney, Thies, Galpin and Head.
Keywords: Activity monitoring, Control, Functionality assessment, Myoelectric, Prosthesis, Upper limb

Identifiers

Local EPrints ID: 483480
URI: http://eprints.soton.ac.uk/id/eprint/483480
PURE UUID: efcad23c-4058-4901-b9d6-3aeb627965fe
ORCID for Alix Chadwell: ORCID iD orcid.org/0000-0002-9101-5202

Catalogue record

Date deposited: 31 Oct 2023 18:05
Last modified: 18 Mar 2024 04:12

Export record

Altmetrics

Contributors

Author: Alix Chadwell ORCID iD
Author: Laurence Kenney
Author: Sibylle Thies
Author: Adam Galpin
Author: John Head

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×