The University of Southampton
University of Southampton Institutional Repository

Estimating flow heterogeneity in natural fracture systems

Estimating flow heterogeneity in natural fracture systems
Estimating flow heterogeneity in natural fracture systems
Examples of small to medium scale fault systems have been mapped in Jurassic sedimentary rocks in north Somerset, England. These examples include contractional and dilational strike-slip oversteps as well as normal faults. These maps form the basis of calculations performed to investigate heterogeneity in natural fracture systems with the aim of predicting fluid flow localisation in different fault styles. As there is no way to measure fracture aperture directly, we use vein thickness to represent an integrated flow path or ‘palaeo-aperture’ from which we derive a representation of the flow distribution. Three different methods are used to estimate flow heterogeneity based on: (1) fracture density (the ratio of fracture length to area), (2) fracture aperture (fracture porosity) and (3) hydraulic conductance (fracture permeability normalised to the pressure gradient and fluid properties).
Our results show that fracture density and hydraulic conductance are poorly correlated and that fracture density does not fully represent the natural heterogeneity of fracture systems. Fracture aperture and hydraulic conductance indicate stronger degrees of flow localisation. Different types of structures also seem to display characteristic and predictable patterns of heterogeneity. Normal fault systems show the highest magnitude of localisation along the faults rather than in the relay ramps, while contractional and dilational strike-slip systems show very strong localisation in the faults and oversteps, respectively. In all cases the amount of damage in the oversteps can modify such patterns of heterogeneity.
fault, fracture, fluid flow, fracture density, fracture aperture, hydraulic conductance, permeability
0377-0273
116-129
Leckenby, R.J.
9d3aa68d-4382-4018-84f2-8a768bcd21e6
Sanderson, D.J.
5653bc11-b905-4985-8c16-c655b2170ba9
Lonergan, L.
69341e1f-7b5d-4cad-833e-9c6eaeedd7be
Leckenby, R.J.
9d3aa68d-4382-4018-84f2-8a768bcd21e6
Sanderson, D.J.
5653bc11-b905-4985-8c16-c655b2170ba9
Lonergan, L.
69341e1f-7b5d-4cad-833e-9c6eaeedd7be

Leckenby, R.J., Sanderson, D.J. and Lonergan, L. (2005) Estimating flow heterogeneity in natural fracture systems. Journal of Volcanology and Geothermal Research, 148 (1-2), 116-129. (doi:10.1016/j.jvolgeores.2005.03.017).

Record type: Article

Abstract

Examples of small to medium scale fault systems have been mapped in Jurassic sedimentary rocks in north Somerset, England. These examples include contractional and dilational strike-slip oversteps as well as normal faults. These maps form the basis of calculations performed to investigate heterogeneity in natural fracture systems with the aim of predicting fluid flow localisation in different fault styles. As there is no way to measure fracture aperture directly, we use vein thickness to represent an integrated flow path or ‘palaeo-aperture’ from which we derive a representation of the flow distribution. Three different methods are used to estimate flow heterogeneity based on: (1) fracture density (the ratio of fracture length to area), (2) fracture aperture (fracture porosity) and (3) hydraulic conductance (fracture permeability normalised to the pressure gradient and fluid properties).
Our results show that fracture density and hydraulic conductance are poorly correlated and that fracture density does not fully represent the natural heterogeneity of fracture systems. Fracture aperture and hydraulic conductance indicate stronger degrees of flow localisation. Different types of structures also seem to display characteristic and predictable patterns of heterogeneity. Normal fault systems show the highest magnitude of localisation along the faults rather than in the relay ramps, while contractional and dilational strike-slip systems show very strong localisation in the faults and oversteps, respectively. In all cases the amount of damage in the oversteps can modify such patterns of heterogeneity.

This record has no associated files available for download.

More information

Published date: 2005
Keywords: fault, fracture, fluid flow, fracture density, fracture aperture, hydraulic conductance, permeability

Identifiers

Local EPrints ID: 48380
URI: http://eprints.soton.ac.uk/id/eprint/48380
ISSN: 0377-0273
PURE UUID: 47653811-cbd9-44da-9957-83ec1b8bd791
ORCID for D.J. Sanderson: ORCID iD orcid.org/0000-0002-2144-3527

Catalogue record

Date deposited: 04 Oct 2007
Last modified: 16 Mar 2024 03:57

Export record

Altmetrics

Contributors

Author: R.J. Leckenby
Author: D.J. Sanderson ORCID iD
Author: L. Lonergan

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×