Data used to create Figure 10 in the article "Nanoparticle interferometer by throw and catch"
Data used to create Figure 10 in the article "Nanoparticle interferometer by throw and catch"
Release and Re-Capture Experiment Data
Data used to create Figure 10 in the "Nanoparticle Interferometer by Throw and Catch" paper: Wardak, J.; Georgescu, T.; Gasbarri, G. Nanoparticle Interferometer by Throw and Catch. Atoms 2023, 1, 0 (accepted in press). Nanoparticle was trapped and cooled, then taken down to low pressure. Function generator sent a signal to EOM which turned off the trap for 50 microseconds and simultaneously triggered the oscilloscope which saved the data. C4-XX-00008.trc is the data from the photodetector that was collecting light scattered by the particle. C2--XX--00008.trc was the signal sent to the oscilloscope directly from the function generator. Note: the signal sent from the function generator to the oscilloscope had a delay relative to the signal sent to the EOM, this was corrected in the data analysis. To correct: shift all data from particle forward by 25 microseconds or the pulse back by 25 microseconds.
University of Southampton
Wardak, Jakub Szymon
7df868f6-b11a-482a-a2db-b777871655d8
Wardak, Jakub Szymon
7df868f6-b11a-482a-a2db-b777871655d8
Wardak, Jakub Szymon
(2024)
Data used to create Figure 10 in the article "Nanoparticle interferometer by throw and catch".
University of Southampton
doi:10.5258/SOTON/D2898
[Dataset]
Abstract
Release and Re-Capture Experiment Data
Data used to create Figure 10 in the "Nanoparticle Interferometer by Throw and Catch" paper: Wardak, J.; Georgescu, T.; Gasbarri, G. Nanoparticle Interferometer by Throw and Catch. Atoms 2023, 1, 0 (accepted in press). Nanoparticle was trapped and cooled, then taken down to low pressure. Function generator sent a signal to EOM which turned off the trap for 50 microseconds and simultaneously triggered the oscilloscope which saved the data. C4-XX-00008.trc is the data from the photodetector that was collecting light scattered by the particle. C2--XX--00008.trc was the signal sent to the oscilloscope directly from the function generator. Note: the signal sent from the function generator to the oscilloscope had a delay relative to the signal sent to the EOM, this was corrected in the data analysis. To correct: shift all data from particle forward by 25 microseconds or the pulse back by 25 microseconds.
Text
README.txt
- Dataset
Other
C2_XX_00008.trc
- Dataset
Other
C4_XX_00008.trc
- Dataset
More information
Published date: January 2024
Identifiers
Local EPrints ID: 486490
URI: http://eprints.soton.ac.uk/id/eprint/486490
PURE UUID: 11708eb9-e068-4662-94d8-87e64df694db
Catalogue record
Date deposited: 24 Jan 2024 17:42
Last modified: 24 Jan 2024 18:21
Export record
Altmetrics
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics