Pitfalls and artifacts using the D-SPECT dedicated cardiac camera
Pitfalls and artifacts using the D-SPECT dedicated cardiac camera
Myocardial perfusion imaging is a well-established and widely used imaging technique for the assessment of patients with known or suspected coronary artery disease. Pitfalls and artifacts associated with conventional gamma cameras are well known, and the ways to avoid and correct them have been described. In recent years solid-state detector dedicated cardiac cameras were introduced and have been shown to offer improved accuracy in addition to new imaging protocols and novel applications. The purpose of this manuscript is to familiarize the readers with the causes and effects of technical, patient-related, and operator-related pitfalls and artifacts associated with the D-SPECT dedicated cardiac camera with solid-state detectors. The manuscript offers guidance on how to avoid these factors, how to detect them, and how to correct better for them, providing high-quality diagnostic images.
Myocardial perfusion imaging, image artifacts, instrumentation
301-310
Allie, Rayjanah
d5b0f533-3548-4b57-afb8-1d366302344e
Hutton, Brian F.
9698ef30-c65a-4bdd-a619-4d3680a7d2bd
Prvulovich, Elizabeth
6935ad9d-99db-4749-9aab-96aed799f56b
Bomanji, Jamshed
ec17ee1c-06bd-41d8-9be3-73b820161385
Michopoulou, Sofia
f21ba2a3-f5d3-4998-801f-1ae72ff5d92c
Ben-Haim, Simona
395ac021-3095-4e10-b803-0c889d6124e8
April 2016
Allie, Rayjanah
d5b0f533-3548-4b57-afb8-1d366302344e
Hutton, Brian F.
9698ef30-c65a-4bdd-a619-4d3680a7d2bd
Prvulovich, Elizabeth
6935ad9d-99db-4749-9aab-96aed799f56b
Bomanji, Jamshed
ec17ee1c-06bd-41d8-9be3-73b820161385
Michopoulou, Sofia
f21ba2a3-f5d3-4998-801f-1ae72ff5d92c
Ben-Haim, Simona
395ac021-3095-4e10-b803-0c889d6124e8
Allie, Rayjanah, Hutton, Brian F., Prvulovich, Elizabeth, Bomanji, Jamshed, Michopoulou, Sofia and Ben-Haim, Simona
(2016)
Pitfalls and artifacts using the D-SPECT dedicated cardiac camera.
Journal of Nuclear Cardiology, 23 (2), .
(doi:10.1007/s12350-015-0277-2).
Abstract
Myocardial perfusion imaging is a well-established and widely used imaging technique for the assessment of patients with known or suspected coronary artery disease. Pitfalls and artifacts associated with conventional gamma cameras are well known, and the ways to avoid and correct them have been described. In recent years solid-state detector dedicated cardiac cameras were introduced and have been shown to offer improved accuracy in addition to new imaging protocols and novel applications. The purpose of this manuscript is to familiarize the readers with the causes and effects of technical, patient-related, and operator-related pitfalls and artifacts associated with the D-SPECT dedicated cardiac camera with solid-state detectors. The manuscript offers guidance on how to avoid these factors, how to detect them, and how to correct better for them, providing high-quality diagnostic images.
This record has no associated files available for download.
More information
Accepted/In Press date: 28 July 2015
Published date: April 2016
Keywords:
Myocardial perfusion imaging, image artifacts, instrumentation
Identifiers
Local EPrints ID: 487911
URI: http://eprints.soton.ac.uk/id/eprint/487911
ISSN: 1532-6551
PURE UUID: 8a14ed8e-6220-437b-87a3-602ca6c7b144
Catalogue record
Date deposited: 08 Mar 2024 18:05
Last modified: 17 Mar 2024 07:57
Export record
Altmetrics
Contributors
Author:
Rayjanah Allie
Author:
Brian F. Hutton
Author:
Elizabeth Prvulovich
Author:
Jamshed Bomanji
Author:
Sofia Michopoulou
Author:
Simona Ben-Haim
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics