The University of Southampton
University of Southampton Institutional Repository

Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography

Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography
Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography

The application of near-infrared spectroscopy (NIRS) to assess microvascular function has shown promising results. An important limitation when using a single source-detector pair, however, is the lack of depth sensitivity. Diffuse optical tomography (DOT) overcomes this limitation using an array of sources and detectors that allow the reconstruction of volumetric hemodynamic changes. This study compares the key parameters of postocclusive reactive hyperemia measured in the forearm using standard NIRS and DOT. We show that while the mean parameter values are similar for the two techniques, DOT achieves much better reproducibility, as measured by the intraclass correlation coefficient (ICC). We show that DOT achieves high reproducibility for muscle oxygen consumption (ICC: 0.99), time to maximal HbO2 (ICC: 0.94), maximal HbO2 (ICC: 0.99), and time to maximal HbT (ICC: 0.99). Absolute reproducibility as measured by the standard error of measurement is consistently smaller and close to zero (ideal value) across all parameters measured by DOT compared to NIRS. We conclude that DOT provides a more robust characterization of the reactive hyperemic response and show how the availability of volumetric hemodynamic changes allows the identification of areas of temporal consistency, which could help characterize more precisely the microvasculature.

diffuse optical tomography, near-infrared spectroscopy, reproducibility
1083-3668
Vidal-Rosas, Ernesto E.
1da82633-b581-468e-b41a-117b6893a84d
Billings, Stephen A.
a67e1eb0-9795-42b0-9d3b-2bc158373cb2
Chico, Timothy J.
b3a4a66c-1f6c-4a0e-8b2a-9522acba2900
Coca, Daniel
322b6da4-a36b-401c-8a67-fd4b7f4d036d
Vidal-Rosas, Ernesto E.
1da82633-b581-468e-b41a-117b6893a84d
Billings, Stephen A.
a67e1eb0-9795-42b0-9d3b-2bc158373cb2
Chico, Timothy J.
b3a4a66c-1f6c-4a0e-8b2a-9522acba2900
Coca, Daniel
322b6da4-a36b-401c-8a67-fd4b7f4d036d

Vidal-Rosas, Ernesto E., Billings, Stephen A., Chico, Timothy J. and Coca, Daniel (2016) Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography. Journal of Biomedical Optics, 21 (6), [040801]. (doi:10.1117/1.JBO.21.6.066012).

Record type: Article

Abstract

The application of near-infrared spectroscopy (NIRS) to assess microvascular function has shown promising results. An important limitation when using a single source-detector pair, however, is the lack of depth sensitivity. Diffuse optical tomography (DOT) overcomes this limitation using an array of sources and detectors that allow the reconstruction of volumetric hemodynamic changes. This study compares the key parameters of postocclusive reactive hyperemia measured in the forearm using standard NIRS and DOT. We show that while the mean parameter values are similar for the two techniques, DOT achieves much better reproducibility, as measured by the intraclass correlation coefficient (ICC). We show that DOT achieves high reproducibility for muscle oxygen consumption (ICC: 0.99), time to maximal HbO2 (ICC: 0.94), maximal HbO2 (ICC: 0.99), and time to maximal HbT (ICC: 0.99). Absolute reproducibility as measured by the standard error of measurement is consistently smaller and close to zero (ideal value) across all parameters measured by DOT compared to NIRS. We conclude that DOT provides a more robust characterization of the reactive hyperemic response and show how the availability of volumetric hemodynamic changes allows the identification of areas of temporal consistency, which could help characterize more precisely the microvasculature.

Text
066012_1 - Version of Record
Available under License Creative Commons Attribution.
Download (3MB)

More information

Accepted/In Press date: 9 May 2016
e-pub ahead of print date: 15 June 2016
Keywords: diffuse optical tomography, near-infrared spectroscopy, reproducibility

Identifiers

Local EPrints ID: 489081
URI: http://eprints.soton.ac.uk/id/eprint/489081
ISSN: 1083-3668
PURE UUID: 1ad55223-6818-49ec-ad00-f50b06c2c913
ORCID for Ernesto E. Vidal-Rosas: ORCID iD orcid.org/0000-0002-4486-7592

Catalogue record

Date deposited: 12 Apr 2024 16:43
Last modified: 13 Apr 2024 02:08

Export record

Altmetrics

Contributors

Author: Ernesto E. Vidal-Rosas ORCID iD
Author: Stephen A. Billings
Author: Timothy J. Chico
Author: Daniel Coca

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×