READ ME File For 'Dataset in support of the paper entitled "Distributed measurement and modified Navier-Stokes model of the gas flow in hollow-core antiresonant fibres"'

Dataset DOI: 10.5258/SOTON/D2982

Date that the file was created: May, 2024

-------------------
GENERAL INFORMATION
-------------------

ReadMe Author: Elizaveta Elistratova, University of Southampton

Date of data collection: September 2022 - May 2023

Information about geographic location of data collection: 

Related projects:
Hollow Core Fibre Photonics

--------------------------
SHARING/ACCESS INFORMATION
-------------------------- 

Licenses/restrictions placed on the data, or limitations of reuse: CC BY

Recommended citation for the data:

This dataset supports the publication:
AUTHORS: Elizaveta Elistratova, Thomas W. Kelly, Ian A. Davidson, Hesham Sakr, Thomas D. Bradley, Austin Taranta, Francesco Poletti, Radan Slavík, Peter Horak, and Natalie V. Wheeler 
TITLE: Distributed measurement and modified Navier-Stokes model of the gas flow in hollow-core antiresonant fibres
JOURNAL: IEEE Journal of Selected Topics in Quantum Electronics
PAPER DOI IF KNOWN:

Links to other publicly accessible locations of the data:

Links/relationships to ancillary or related data sets: 


--------------------
DATA & FILE OVERVIEW
--------------------

This dataset contains:

[JSTQE_2024_pure_data.xls - modelling and experimental measurements of the time evolution of the pressure distribution inside the nested antiresonant nodeless fibre pressurised from one end at 3, 4.5, and 6 bar.]


Relationship between files, if important for context:  

Additional related data collected that was not included in the current data package:

If data was derived from another source, list source: The file was colated in Origin 2022b so it includes special symbols for text formating ("Rich Text")

If there are there multiple versions of the dataset, list the file updated, when and why update was made:



--------------------------
METHODOLOGICAL INFORMATION
--------------------------

Description of methods used for collection/generation of data: experimental data was collected using the setup described in the paper, modelling data and fitting data was generated in MATLAB.

Methods for processing the data: experimental data was interpolated over the same time vector.

Software- or Instrument-specific information needed to interpret the data, including software and hardware version numbers: 

Standards and calibration information, if appropriate:

Environmental/experimental conditions: 20 degree Celsius, 1 bar

Describe any quality-assurance procedures performed on the data:

People involved with sample collection, processing, analysis and/or submission: Elizaveta Elistratova, Thomas W. Kelly, Ian A. Davidson, Austin Taranta, Radan Slavík, Peter Horak, and Natalie V. Wheeler 


--------------------------
DATA-SPECIFIC INFORMATION <Create sections for each datafile or set, as appropriate>
--------------------------

JSTQE_2024_pure_data.xls/Fig2a

Number of variables: 2

Number of cases/rows: 6/436

Variable list, defining any abbreviations, units of measure, codes or symbols used: Lenght [m] - fibre length in meters, Pressure [bar] - pressure in the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: t - time from the beggining of filling/venting


JSTQE_2024_pure_data.xls/Fig2b

Number of variables: 2

Number of cases/rows: 6/436

Variable list, defining any abbreviations, units of measure, codes or symbols used: Lenght [m] - fibre length in meters, Pressure [bar] - pressure in the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: t - time from the beggining of filling/venting


JSTQE_2024_pure_data.xls/Fig2c

Number of variables: 2

Number of cases/rows: 4/161

Variable list, defining any abbreviations, units of measure, codes or symbols used: Pressure [bar] - filling pressure, Dim-less filling/venting time - dimensionless unit of time to filled/vented state
   
Missing data codes: NaN

Specialized formats or other abbreviations used: num - nimerical, fit - fitted, (a,b,c) - patameters of the fit


JSTQE_2024_pure_data.xls/Fig2d

Number of variables: 3

Number of cases/rows: 4/145

Variable list, defining any abbreviations, units of measure, codes or symbols used: Lenght [m] - fibre length in meters, Pressure [bar] - filling pressure, Backscattering - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: Dc - fibre core diameter


JSTQE_2024_pure_data.xls/Fig3b

Number of variables: 2

Number of cases/rows: 4/199

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig4a

Number of variables: 3

Number of cases/rows: 2/14500

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Time [h] - time elapsed from the start of filling/venting, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig4b

Number of variables: 2

Number of cases/rows: 11/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared)

Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig4c

Number of variables: 3

Number of cases/rows: 4/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared), Std - standard deviation

Missing data codes: NaN

Specialized formats or other abbreviations used: over all - averaged over all time steps, over 2 - averaged over 2 first time steps (excluding 0) 


JSTQE_2024_pure_data.xls/Fig4d

Number of variables: 3

Number of cases/rows: 2/14500

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Time [h] - time elapsed from the start of filling/venting, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig4e

Number of variables: 2

Number of cases/rows: 11/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared)

Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig4f

Number of variables: 3

Number of cases/rows: 4/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared), Std - standard deviation

Missing data codes: NaN

Specialized formats or other abbreviations used: over all - averaged over all time steps, over 2 - averaged over 2 first time steps (excluding 0) 


JSTQE_2024_pure_data.xls/Fig4g

Number of variables: 3

Number of cases/rows: 6/1985

Variable list, defining any abbreviations, units of measure, codes or symbols used: Time [h] - time elapsed from the start of filling/venting, Normalised backscattering - averaged over fibre length and normalised to the last value backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: pol - fitted using a polynominal function


JSTQE_2024_pure_data.xls/Fig4h

Number of variables: 3

Number of cases/rows: 6/1985

Variable list, defining any abbreviations, units of measure, codes or symbols used: Time [h] - time elapsed from the start of filling/venting, Normalised backscattering - averaged over fibre length and normalised to the last value backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: pol - fitted using a polynominal function


JSTQE_2024_pure_data.xls/Fig5a

Number of variables: 3

Number of cases/rows: 2/29725

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Time [h] - time elapsed from the start of filling/venting, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig5b

Number of variables: 3

Number of cases/rows: 2/48720

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Time [h] - time elapsed from the start of filling/venting, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig5c

Number of variables: 3

Number of cases/rows: 2/22330

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Time [h] - time elapsed from the start of filling/venting, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig5a

Number of variables: 3

Number of cases/rows: 2/41180

Variable list, defining any abbreviations, units of measure, codes or symbols used: Fibre lenght [m] - fibre length in meters, Time [h] - time elapsed from the start of filling/venting, Backscattering [db] - backscattering coefficient of the gas inside the fibre
   
Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig6a

Number of variables: 2

Number of cases/rows: 11/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared)

Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig6b

Number of variables: 3

Number of cases/rows: 4/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared), Std - standard deviation

Missing data codes: NaN

Specialized formats or other abbreviations used: over all - averaged over all time steps, over 2 - averaged over 2 first time steps (excluding 0) 


JSTQE_2024_pure_data.xls/Fig6c

Number of variables: 2

Number of cases/rows: 11/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared)

Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig6d

Number of variables: 3

Number of cases/rows: 4/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared), Std - standard deviation

Missing data codes: NaN

Specialized formats or other abbreviations used: over all - averaged over all time steps, over 2 - averaged over 2 first time steps (excluding 0) 


JSTQE_2024_pure_data.xls/Fig7a

Number of variables: 2

Number of cases/rows: 11/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared)

Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig7b

Number of variables: 3

Number of cases/rows: 4/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared), Std - standard deviation

Missing data codes: NaN

Specialized formats or other abbreviations used: over all - averaged over all time steps, over 2 - averaged over 2 first time steps (excluding 0) 


JSTQE_2024_pure_data.xls/Fig7c

Number of variables: 2

Number of cases/rows: 11/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared)

Missing data codes: NaN

Specialized formats or other abbreviations used: 


JSTQE_2024_pure_data.xls/Fig7d

Number of variables: 3

Number of cases/rows: 4/11

Variable list, defining any abbreviations, units of measure, codes or symbols used: Eff. diameter coefficient keff - effective diameter coefficient, R2 -  coefficient of determination (r-squared), Std - standard deviation

Missing data codes: NaN

Specialized formats or other abbreviations used: over all - averaged over all time steps, over 2 - averaged over 2 first time steps (excluding 0)